{"product_id":"is200staih2aba-mark-vie-simplex-analog-input-terminal-board-ge-request-quote","title":"IS200STAIH2ABA Mark VIe Simplex Analog Input Terminal Board GE - Request Quote","description":"\u003cdiv\u003e\n  \u003ch2\u003eIS200STAIH2ABA General Electric Mark VIe Simplex Analog Input Terminal Board Overview\u003c\/h2\u003e\n  \u003cp\u003eThe \u003cstrong\u003eIS200STAIH2ABA\u003c\/strong\u003e is a high-density Simplex Analog Input (STAI) terminal board engineered by \u003cstrong\u003eGeneral Electric\u003c\/strong\u003e for the \u003cstrong\u003eMark VIe\u003c\/strong\u003e distributed control platform. Designed to interface directly with the specialized \u003cstrong\u003ePAIC\u003c\/strong\u003e I\/O pack via a secure D-type connector, this compact hardware module manages 10 analog inputs and 2 analog outputs. Protected by a uniform chemical conformal coating, it provides robust signal conditioning for industrial automation transmitters and transducers in single-loop architectures.\u003c\/p\u003e\n\n  \u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n  \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eGeneral Electric (GE Energy)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eIS200STAIH2ABA\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eMark VIe\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTerminal Board Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSimplex Analog Input (STAI)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 Analog Inputs \/ 2 Analog Outputs (12 Channels Total)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Lead Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15 Ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransmitter Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.9 cm High x 10.2 cm Wide\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-30 to +65 degrees Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePCB Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConformal Coated Surface Mount Technology\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWarranty \u0026amp; Fulfillment\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12-Month Coverage; Dispatch via FedEx, UPS, DHL (24-48h)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch3\u003eHardware Configuration \u0026amp; Jumper Architecture\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInput Signal Conditioning:\u003c\/strong\u003e Jumpers \u003cstrong\u003eJ1A through J8A\u003c\/strong\u003e allow engineers to switch dynamically between current and voltage input modes. Jumpers \u003cstrong\u003eJ1B through J8B\u003c\/strong\u003e establish whether input return paths link directly to common or remain open, with secondary current adjustments managed via \u003cstrong\u003eJ9A\/J9B\u003c\/strong\u003e and \u003cstrong\u003eJ10A\/J10B\u003c\/strong\u003e.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e Output 1 is permanently fixed to a standard 4-20 mA loop format, while Output 2 can be reconfigured using jumper \u003cstrong\u003eJ0\u003c\/strong\u003e to support either 4-20 mA or an extended 0-200 mA range.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting Flexibility:\u003c\/strong\u003e Mounts securely onto standard DIN-rails using an integrated sheet metal carrier with a plastic insulator or fastens directly to control cabinet backing panels via dedicated sheet metal assemblies.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCabling Standards:\u003c\/strong\u003e Recommended field cabling utilizes #18 AWG shielded twisted pair wiring, with dedicated shield termination lugs positioned adjacent to the Euro-block terminal strips to minimize electromagnetic noise pickup.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eDiagnostics \u0026amp; System Integration\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOnboard ID Recognition:\u003c\/strong\u003e Incorporates a read-only memory chip encoding the board serial number, revision index, and connector layout. The Mark VIe I\/O controller queries this ID chip during boot-up; any mismatch immediately triggers a hardware incompatibility fault.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLoop Health Tracking:\u003c\/strong\u003e Output current status is evaluated by measuring the voltage drop across an internal series resistor, allowing the control system to flag unhealthy loops instantly.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eTypical Applications \u0026amp; Compatible Equipment\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProcess Control Skids:\u003c\/strong\u003e Manages multi-variable transmitter inputs and control valve feedback loops in industrial manufacturing environments.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePower Generation Turbines:\u003c\/strong\u003e Handles analog sensor signal collection for auxiliary fluid systems within GE Mark VIe plant architectures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompatible Hardware:\u003c\/strong\u003e Interfaces seamlessly with PAIC I\/O packs and GE Energy distributed control processor nodes.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n  \u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can the \u003cstrong\u003eIS200STAIH2ABA\u003c\/strong\u003e terminal board be deployed in Triple Modular Redundancy (TMR) safety systems?\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e No, because it relies on a single cable connection configuration, it is strictly designed for simplex control loops rather than TMR architectures.\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What purpose do the onboard jumper blocks serve on this terminal unit?\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Jumpers allow technicians to configure input signal types (current versus voltage), manage return path grounding, and scale output current ranges.\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How does the control system verify that the correct terminal board is installed?\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The I\/O controller queries an onboard read-only ID chip that automatically transmits the board's serial number, type, and connector placement data.\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What physical wiring practices are recommended for connecting field transmitters to this board?\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Engineers should use #18 AWG shielded twisted pair cables and secure the cable shields to the designated grounding terminals near the Euro-blocks.\u003c\/p\u003e\n\n  \u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What dispatch and protection terms are included with an OEM purchase of the \u003cstrong\u003eIS200STAIH2ABA\u003c\/strong\u003e?\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Orders ship within 24 to 48 hours via FedEx, UPS, or DHL, and every unit is backed by a comprehensive 12-month operational warranty.\u003c\/p\u003e\n\n  \u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n  \u003cp\u003eWhen commissioning an \u003cstrong\u003eIS200STAIH2ABA\u003c\/strong\u003e in high-vibration industrial settings, field engineers frequently encounter erratic analog readings if jumper settings do not match the physical transmitter loop configuration. \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e recommends verifying that all jumper blocks (J1A-J10B) are securely seated and checked against your loop sheets before applying 24 V DC power. Always inspect the D-type interface connection to the PAIC pack to prevent communication timeouts during system startup.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45372758294710,"sku":"IS200STAIH2ABA","price":365.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IS200STAIH2ABA.jpg?v=1787285367","url":"https:\/\/www.plcsparehub.com\/products\/is200staih2aba-mark-vie-simplex-analog-input-terminal-board-ge-request-quote","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}