{"product_id":"is200erbpg1aca-backplane-board-ge-ex2100-exciter-series-module","title":"IS200ERBPG1ACA Backplane Board GE EX2100 Exciter Series Module","description":"\u003ch3\u003e\u003cstrong\u003eGE EX2100 IS200ERBPG1ACA Product Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB Insight: The \u003cstrong\u003eIS200ERBPG1ACA\u003c\/strong\u003e (revision ACA) functions as an advanced Exciter Regulator Backplane (ERBP) engineered specifically for the \u003cstrong\u003eEX2100\u003c\/strong\u003e turbine control architecture and the Mark VI ecosystem. Manufactured domestically in Salem, Virginia, this specialized printed circuit board acts as the central communication and power distribution backbone. It securely interconnects critical sub-modules including IGBT, EPSM, ERDD, ERIO, ACLA, and DSPX cards, ensuring reliable high-voltage excitation management across heavy industrial power generation units.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical \u0026amp; Electrical Metrics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Brand:\u003c\/strong\u003e GE Industrial Systems (General Electric)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003cstrong\u003eEX2100\u003c\/strong\u003e Exciter Turbine Control \/ Mark VI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Part Number:\u003c\/strong\u003e \u003cstrong\u003eIS200ERBPG1ACA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type \u0026amp; Revision:\u003c\/strong\u003e Normal Assembly, Revision ACA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Count:\u003c\/strong\u003e 12 input channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Span Range:\u003c\/strong\u003e 4 to 20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Voltage Range:\u003c\/strong\u003e plus or minus 5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Lead Resistance:\u003c\/strong\u003e 15 ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Output Current:\u003c\/strong\u003e 0 to 20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e 8.26 cm high x 4.19 cm depth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30 to 65 degrees Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOriginal Reference Manual:\u003c\/strong\u003e GEI-100521A \/ GEI-100488a\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Architecture \u0026amp; Installation Framework\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConstructed with a rugged outward rectangular chassis featuring integrated cooling airflow perforations and mounting flanges.\u003c\/li\u003e\n\u003cli\u003eUtilizes 3U or 6U VME 96-pin and 128-pin DIN backplane connectors to distribute operational power and data signals.\u003c\/li\u003e\n\u003cli\u003eIncorporates an onboard board identification (ID) serial bus that reads barcode serial numbers, board types, and hardware revisions automatically.\u003c\/li\u003e\n\u003cli\u003eFeatures master selection jumpers configured explicitly for simplex or redundant exciter regulator applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility \u0026amp; Equipment Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned natively for GE's third-generation digital excitation scheme within the \u003cstrong\u003eEX2100\u003c\/strong\u003e platform.\u003c\/li\u003e\n\u003cli\u003eIntegrates seamlessly with Mark VI central control operator interfaces and CIMPLICITY HMI supervisory graphics.\u003c\/li\u003e\n\u003cli\u003eSupports stand-alone system retrofits through robust Ethernet Modbus and serial communication protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics \u0026amp; Fault Protection Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated board ID telemetry provides real-time health monitoring of all slotted sub-assemblies.\u003c\/li\u003e\n\u003cli\u003eBuilt-in protection circuitry safeguards generator excitation stages against overvoltage and overcurrent transients.\u003c\/li\u003e\n\u003cli\u003eActive backplane communication diagnostics allow technicians to isolate faults quickly without extensive system downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics, Fulfillment \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInventory Status:\u003c\/strong\u003e In stock and ready for immediate deployment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Speed:\u003c\/strong\u003e Rapid processing and dispatch within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Carriers:\u003c\/strong\u003e Safe, tracked global delivery via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Protection:\u003c\/strong\u003e Fully covered by a standard 12-month replacement or repair guarantee.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas and steam-powered turbine generator excitation and voltage regulation plants.\u003c\/li\u003e\n\u003cli\u003eAlternative energy wind turbine automated drive management systems.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial electrical power generation and distribution substations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePurchasing Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that your existing exciter rack matches the \u003cstrong\u003eEX2100\u003c\/strong\u003e architecture before ordering the \u003cstrong\u003eIS200ERBPG1ACA\u003c\/strong\u003e replacement board.\u003c\/li\u003e\n\u003cli\u003eConfirm whether your setup requires simplex or redundant jumper configurations during initial deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What is the precise function of the onboard board ID serial bus on the \u003cstrong\u003eIS200ERBPG1ACA\u003c\/strong\u003e backplane?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The serial bus interfaces directly with each slotted sub-board's onboard memory chip, instantly pulling its barcode serial number, hardware revision, and board type for automatic controller recognition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can the \u003cstrong\u003eIS200ERBPG1ACA\u003c\/strong\u003e module be integrated into non-Mark VI legacy turbine systems?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Yes, while optimized for the Mark VI and \u003cstrong\u003eEX2100\u003c\/strong\u003e ecosystems, it can support stand-alone retrofit applications when interfaced via standard Ethernet Modbus or serial communication protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How do master selection jumpers affect the operational mode of this backplane?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The physical jumpers must be correctly set to establish either simplex or redundant exciter regulator control topologies depending on plant safety requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What precautions should field engineers take regarding lead resistance when wiring inputs to the \u003cstrong\u003eIS200ERBPG1ACA\u003c\/strong\u003e?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Field wiring must strictly maintain a maximum lead resistance of 15 ohms to prevent signal degradation across the 4-20 mA input span.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Why is proper cabinet airflow critical when operating the \u003cstrong\u003eIS200ERBPG1ACA\u003c\/strong\u003e?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Although the chassis features integrated perforation panels and a rear cooling fan, maintaining ambient temperatures below 65 degrees Celsius prevents thermal drift in sensitive analog current loops.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45013996470454,"sku":"IS200ERBPG1ACA","price":143.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IS200ERBPG1ACA_86c233be-28ee-4d8b-a3b5-070bbe62a715.jpg?v=1788335219","url":"https:\/\/www.plcsparehub.com\/products\/is200erbpg1aca-backplane-board-ge-ex2100-exciter-series-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}