{"product_id":"is200epctg1aaa-mark-vi-ex2100-series-terminal-board-ge-i-o","title":"IS200EPCTG1AAA Mark VI\/EX2100 Series Terminal Board | GE I\/O","description":"\u003ch3 style=\"color: #2e7d32;\"\u003eEngineering Precision: The \u003cstrong\u003e\u003cspan style=\"color: #2e7d32;\"\u003eIS200EPCTG1AAA\u003c\/span\u003e\u003c\/strong\u003e Module\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e7d32;\"\u003eIS200EPCTG1AAA\u003c\/span\u003e\u003c\/strong\u003e serves as a high-fidelity Exciter PT\/CT (EPCT) terminal board within the \u003cstrong\u003e\u003cspan style=\"color: #2e7d32;\"\u003eGE EX2100\u003c\/span\u003e\u003c\/strong\u003e and Mark VI control ecosystems. Engineered for mission-critical power generation, this interface converts high-voltage generator outputs into isolated, low-voltage control signals. Its design prioritizes signal integrity through transformer-coupled isolation, ensuring that downstream EMIO processors receive clean, reliable data for turbine regulation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2e7d32;\"\u003eCritical Technical Architecture\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries Compatibility:\u003c\/strong\u003e Optimized for \u003cstrong\u003e\u003cspan style=\"color: #2e7d32;\"\u003eEX2100\u003c\/span\u003e\u003c\/strong\u003e Excitation and Mark VI Speedtronic platforms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e 6-channel throughput consisting of 2 three-phase PT inputs and 2 CT inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Scaling:\u003c\/strong\u003e Dual-winding support for 1A or 5A CT inputs; field-selectable configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Conditioning:\u003c\/strong\u003e Three-wire open delta voltage measurement; 115V rms input to 1.533V rms output.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Envelope:\u003c\/strong\u003e Rated for operation between -30°C and +65°C.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Geometry:\u003c\/strong\u003e 8.6 cm (W) x 16.2 cm (H) footprint for efficient cabinet density.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Connectivity:\u003c\/strong\u003e Three front-facing terminal strips and three rear-mounted pin connectors (J305, J308, J315).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #2e7d32;\"\u003eDiagnostic Intelligence \u0026amp; System Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e7d32;\"\u003eIS200EPCTG1AAA\u003c\/span\u003e\u003c\/strong\u003e features 12 integrated test points (TP1-TP12) for real-time secondary-side signal monitoring. Its architecture supports up to three redundant boards, ensuring high availability in M1\/M2\/C controller setups. Fixed-mount TB2\/TB3 terminals prevent accidental open-circuits in critical current loops, enhancing total system safety.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2e7d32;\"\u003eGlobal PLC Spare HUB Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e7d32;\"\u003eIS200EPCTG1AAA\u003c\/span\u003e\u003c\/strong\u003e is essential for generator synchronization where voltage stability is paramount. Our engineering insight confirms its suitability for heavy-duty gas turbine valve positioning and excitation feedback, providing the robust isolation required for long-term industrial utility operation.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2e7d32;\"\u003eLogistics and Quality Assurance\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRapid Dispatch:\u003c\/strong\u003e Orders processed within 24–48 hours for immediate deployment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Shipping:\u003c\/strong\u003e Secure transport via FedEx, UPS, and DHL.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Industry-leading 12-month quality assurance guarantee.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Protected in anti-static, shock-resistant materials for safe international transit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #2e7d32;\"\u003eProfessional FAQ\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuestion:\u003c\/strong\u003e Is the \u003cstrong\u003e\u003cspan style=\"color: #2e7d32;\"\u003eIS200EPCTG1AAA\u003c\/span\u003e\u003c\/strong\u003e compatible with older EPCT versions?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnswer:\u003c\/strong\u003e Yes, it maintains backward compatibility with the first two revisions of the series.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuestion:\u003c\/strong\u003e What are the cable distance limits for this board?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnswer:\u003c\/strong\u003e PT inputs accommodate up to 1000 ft with 12 AWG wire, while CT inputs support 1000 ft with 10 AWG.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuestion:\u003c\/strong\u003e Why is ground isolation important during diagnostics?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnswer:\u003c\/strong\u003e The secondary side references can be easily skewed by ground loops, causing inaccurate measurements at the test points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuestion:\u003c\/strong\u003e How to verify CT output health?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnswer:\u003c\/strong\u003e Use a multimeter on TP9-TP12 to correlate the secondary output against the expected primary input ratio.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can this be used in redundant TMR systems?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAnswer:\u003c\/strong\u003e Yes, it is fully designed to support triple-redundant architectures when connected to the J305, J308, and J315 headers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #2e7d32;\"\u003eSelection \u0026amp; Implementation Guide\u003c\/h3\u003e\n\u003cp\u003eWhen selecting the \u003cstrong\u003e\u003cspan style=\"color: #2e7d32;\"\u003eIS200EPCTG1AAA\u003c\/span\u003e\u003c\/strong\u003e, verify your current excitation cabinet layout to accommodate the 8.6cm x 16.2cm footprint. During installation, always confirm jumper settings for 1A or 5A current inputs before applying site power. Utilizing GE Toolbox software post-installation is recommended to confirm proper ID chip recognition by the Excitation EMIO controller.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45188104945846,"sku":"IS200EPCTG1AAA","price":421.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IS200EPCTG1AAA.jpg?v=1781591205","url":"https:\/\/www.plcsparehub.com\/products\/is200epctg1aaa-mark-vi-ex2100-series-terminal-board-ge-i-o","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}