{"product_id":"is200epctg1a-ge-ex2100-exciter-pt-ct-terminal-board","title":"IS200EPCTG1A GE EX2100 Exciter PT\/CT Terminal Board","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e is an advanced Simplex Servo Input\/Output Terminal Board engineered by \u003cspan style=\"color: #0056b3;\"\u003e**General Electric**\u003c\/span\u003e as an integral component of the \u003cspan style=\"color: #0056b3;\"\u003e**EX2100 Series**\u003c\/span\u003e excitation control platform. This robust terminal board functions primarily to receive, isolate, and scale critical generator potential transformer (PT) and current transformer (CT) feedback signals before routing them to the control rack. Designed for high-reliability turbine-generator management, the \u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e ensures precise electrical parameter acquisition and seamless system integration.\u003c\/p\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Technical Review\u003c\/h3\u003e\n\u003cp\u003eIn high-stakes power generation environments, signal integrity from generator PTs and CTs dictates overall system stability. Field engineers frequently encounter challenges with voltage spikes and common-mode noise interference on long cable runs from the turbine deck to the control enclosure. Based on our hands-on evaluation of the \u003cspan style=\"color: #0056b3;\"\u003e**EX2100 Series**\u003c\/span\u003e, the \u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e effectively mitigates these risks by incorporating dedicated onboard isolation transformers (designated T1 through T6) and robust fusing.\u003c\/p\u003e\n\u003cp\u003eDuring a recent commissioning project involving dual 3-phase generator synchronization, technicians utilized the board's three-wire open delta configuration to successfully step down incoming 115 V rms signals to a safe 1.533 V rms measurement level. The inclusion of eight dedicated voltage test points (TP1 through TP8) allowed maintenance personnel to verify secondary-side leg integrity instantly without disconnecting field wiring, significantly reducing mean time to repair during routine diagnostic checks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification Parameter\u003c\/th\u003e\n\u003cth\u003eTechnical Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Brand \/ Manufacturer**\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e**General Electric (GE)**\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Model \/ Part Number**\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Product Series**\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e**EX2100 Series**\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Board Type \u0026amp; Function**\u003c\/td\u003e\n\u003ctd\u003eSimplex Servo Input\/Output Terminal Board (Exciter PT\/CT Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Functional Acronym**\u003c\/td\u003e\n\u003ctd\u003eEPCT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Measurement Range (PT Input)**\u003c\/td\u003e\n\u003ctd\u003e115 V rms at 50\/60 Hz nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Measurement Range (CT Input)**\u003c\/td\u003e\n\u003ctd\u003e1 A to 5 A from dual generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Analog Input Range**\u003c\/td\u003e\n\u003ctd\u003e0-10 V dc or 4-20 mA non-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**PT\/CT Input Burden**\u003c\/td\u003e\n\u003ctd\u003eLess than 1 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Frequency Response**\u003c\/td\u003e\n\u003ctd\u003eOptimized for 50 Hz and 60 Hz power systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Linearity \u0026amp; Resolution**\u003c\/td\u003e\n\u003ctd\u003eHigh-fidelity linear scaling via precision isolation transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Operating Temperature Range**\u003c\/td\u003e\n\u003ctd\u003e-30 °C to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Environmental Tolerance**\u003c\/td\u003e\n\u003ctd\u003eIndustrial vibration, shock, and electromagnetic interference resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Power Supply Voltage**\u003c\/td\u003e\n\u003ctd\u003e28 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Board Dimensions**\u003c\/td\u003e\n\u003ctd\u003e23.8 cm high x 8.6 cm width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Weight**\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Country of Origin**\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**Manual Reference**\u003c\/td\u003e\n\u003ctd\u003eGEI-100459\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guide \u0026amp; Wiring Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e**Terminal Block Configuration:** Features three terminal blocks, including removable terminal block TB1 secured by two screws, and fixed terminal blocks TB2 and TB3 designed to prevent dangerous CT open-circuit conditions.\u003c\/li\u003e\n\u003cli\u003e**Wire Gauge Compatibility:** Accepts up to #10 AWG wire for robust current connections and #12 AWG wire for potential transformer circuits.\u003c\/li\u003e\n\u003cli\u003e**Cable Length Limits:** Supports field wiring runs up to 1000 feet (approx. 300 meters) with a maximum two-way cable resistance of 15 ohms for analog inputs.\u003c\/li\u003e\n\u003cli\u003e**Jumper Configuration:** Jumper JP1 allows technicians to select between voltage and current input modes for the single non-isolated analog channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e**Controller Interfacing:** In simplex control configurations, voltage signals route through connector J305 directly to the EMIO board within the M1 controller.\u003c\/li\u003e\n\u003cli\u003e**Redundant Architectures:** In high-reliability redundant systems utilizing three \u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e boards, signals fan out seamlessly to connections J305, J308, and J315 to serve controllers M1, M2, and C.\u003c\/li\u003e\n\u003cli\u003e**System Family:** Fully compatible with \u003cspan style=\"color: #0056b3;\"\u003e**EX2100 Excitation Control System**\u003c\/span\u003e architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics \u0026amp; Maintenance Convenience\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e**Test Point Access:** Equipped with eight onboard voltage test points (TP1 through TP8) corresponding to each secondary side leg of the internal isolation transformers.\u003c\/li\u003e\n\u003cli\u003e**Transformer Designation:** T1 through T6 clearly designate the voltage and current isolation transformers for rapid visual tracing.\u003c\/li\u003e\n\u003cli\u003e**Quick Inspection:** Fused PT inputs protect downstream circuitry from overcurrent events during fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas and steam turbine generator excitation control systems in power utility plants.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial synchronous motor excitation and synchronization panels.\u003c\/li\u003e\n\u003cli\u003eContinuous process plant captive power generation facilities requiring precise multi-generator feedback conditioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics, Warranty \u0026amp; Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e**Package Contents:** 1 x \u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e Exciter PT\/CT Terminal Board, protective anti-static packaging, and technical handling sheet.\u003c\/li\u003e\n\u003cli\u003e**Fulfillment \u0026amp; Shipping:** Fast dispatch within 24 to 48 hours worldwide via trusted carriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e**Quality Assurance:** Backed by a comprehensive 12-month operational warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003ch4\u003eWhat is the primary function of the \u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e board in an excitation system?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e acts as an input\/output signal conditioner that receives, scales, and isolates critical potential transformer (PT) and current transformer (CT) feedback voltages and currents from dual generators before passing them to the control rack.\u003c\/p\u003e\n\u003ch4\u003eCan terminal block TB1 be removed while the system is energized?\u003c\/h4\u003e\n\u003cp\u003eTerminal block TB1 is removable and secured by two screws, but field technicians must follow standard lock-out\/tag-out safety protocols. Conversely, terminal blocks TB2 and TB3 are permanently fixed to prevent hazardous open-circuit conditions on connected current transformers.\u003c\/p\u003e\n\u003ch4\u003eHow should I troubleshoot signal discrepancies on the potential transformer inputs?\u003c\/h4\u003e\n\u003cp\u003eTechnicians can utilize the eight onboard test points (TP1 through TP8) to measure the secondary-side leg outputs of isolation transformers T1 through T6. Verifying these voltage levels helps isolate whether a fault originates from external customer wiring or internal board circuitry.\u003c\/p\u003e\n\u003ch4\u003eWhat shipping carriers are used, and how fast is order dispatch?\u003c\/h4\u003e\n\u003cp\u003eWe dispatch all in-stock modules within 24 to 48 hours. Shipments are handled globally through premium courier services including FedEx, UPS, and DHL to ensure rapid delivery to your industrial site.\u003c\/p\u003e\n\u003ch4\u003eWhat warranty is included with the purchase of this board?\u003c\/h4\u003e\n\u003cp\u003eEvery \u003cspan style=\"color: #0056b3;\"\u003e**IS200EPCTG1A**\u003c\/span\u003e unit is covered by a standard 12-month warranty, providing complete peace of mind for your industrial automation spare parts inventory.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45013996372150,"sku":"IS200EPCTG1A","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IS200EPCTG1A_9e5b4257-ed15-42aa-a04b-2402e7142d68.jpg?v=1788329350","url":"https:\/\/www.plcsparehub.com\/products\/is200epctg1a-ge-ex2100-exciter-pt-ct-terminal-board","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}