{"product_id":"is200edcfg1baa-general-electric-ex2100-exciter-dc-feedback-board-in-stock","title":"IS200EDCFG1BAA General Electric EX2100 Exciter DC Feedback Board | In Stock","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIS200EDCFG1BAA\u003c\/span\u003e\u003c\/strong\u003e module is an advanced \u003cstrong\u003eExciter DC Feedback Board\u003c\/strong\u003e engineered for the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eEX2100\u003c\/span\u003e\u003c\/strong\u003e excitation system by \u003cstrong\u003eGeneral Electric\u003c\/strong\u003e. It monitors field current and SCR bridge voltage with high precision. This component ensures stable excitation control in heavy industrial drives.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eEX2100\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIS200EDCFG1BAA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eExciter DC Feedback Board\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eField current shunt up to 500 mV; Bridge voltage 140V to 1400V rms\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eVCO frequency modulation directly proportional to input voltage\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eSensitivity \u0026amp; Linearity\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eDifferential amplifier output regulated from -5V to +5V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eHigh-resolution optical feedback transmission\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-30°C to 65°C\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eEnvironmental Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eNormal chemical PCB coating (G1 rating)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eInterference Immunity\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eHigh noise immunity via fiber-optic isolation links\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eDimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e15.9 cm x 10.2 cm; Surface-mount technology\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Setup Guide\u003c\/h3\u003e\n\u003cp\u003eProper installation guarantees long-term hardware reliability in demanding electrical rooms:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIS200EDCFG1BAA\u003c\/span\u003e\u003c\/strong\u003e securely inside the designated drive control cabinet.\u003c\/li\u003e\n  \u003cli\u003eConnect external 24V DC power using terminal J16 to energize internal regulators.\u003c\/li\u003e\n  \u003cli\u003eAttach plastic type fiber cables (up to 10m) or hard-clad silica cables (up to 90m) to ports CF OF and VF OF.\u003c\/li\u003e\n  \u003cli\u003eMaintain a strict minimum bending radius of 1.5 inches for all connected fiber cables to prevent signal attenuation.\u003c\/li\u003e\n  \u003cli\u003eConfigure the eight bridge voltage scaling jumpers to match your specific PPT input voltage requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDebugging \u0026amp; Maintenance Convenience\u003c\/h3\u003e\n\u003cp\u003eEngineers can quickly assess operational status using onboard diagnostic indicators:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify the \u003cstrong\u003ePSOK\u003c\/strong\u003e green LED indicator to confirm normal power supply voltage rails.\u003c\/li\u003e\n  \u003cli\u003eInspect high-speed fiber-optic links for secure seating and clean optical connectors.\u003c\/li\u003e\n  \u003cli\u003eCheck differential amplifier output test points if current feedback signals drift.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \u0026amp; System Integration\u003c\/h3\u003e\n\u003cp\u003eThe board integrates seamlessly within existing plant architectures:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned exclusively for \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eEX2100\u003c\/span\u003e\u003c\/strong\u003e excitation control systems.\u003c\/li\u003e\n  \u003cli\u003eCommunicates directly with the EISB control panel board via high-speed optical links.\u003c\/li\u003e\n  \u003cli\u003eUses HFBR-1528 fiber optic drivers for robust data exchange.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCertifications, Warranty \u0026amp; Logistics\u003c\/h3\u003e\n\u003cp\u003eWe ensure fast fulfillment and reliable operational standards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e Manufactured to strict industrial USA quality standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Backed by a comprehensive 12-month warranty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Logistics:\u003c\/strong\u003e Fast 24-48 hour dispatch via FedEx, UPS, and DHL.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1 x \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIS200EDCFG1BAA\u003c\/span\u003e\u003c\/strong\u003e Board and factory data sheet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIS200EDCFG1BAA\u003c\/span\u003e\u003c\/strong\u003e board deploys effectively across heavy industries:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge synchronous generator excitation regulation in power generation plants.\u003c\/li\u003e\n  \u003cli\u003eHigh-capacity DC motor drives and heavy manufacturing SCR bridges.\u003c\/li\u003e\n  \u003cli\u003eOil and gas compressor stations requiring high noise immunity control loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eWhen commissioning the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eEX2100\u003c\/span\u003e\u003c\/strong\u003e system, field engineers often encounter communication alarms if fiber cables are routed too close to high-voltage power conduits. Maintaining physical separation and respecting the 1.5-inch bend radius prevents micro-fractures in the silica core. In our field experience, checking the \u003cstrong\u003ePSOK\u003c\/strong\u003e LED first during startup saves hours of troubleshooting when verifying auxiliary 24V supply stability.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What causes the PSOK LED indicator to turn off during operation?\u003c\/strong\u003e\u003cbr\u003e\nA: The PSOK LED turns off if the external 24V DC supply drops below operational thresholds or if internal voltage regulators experience a short circuit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use plastic fiber cables for runs longer than 15 meters?\u003c\/strong\u003e\u003cbr\u003e\nA: No, plastic type fibers are rated for distances up to 10 meters. For longer runs up to 90 meters, use hard-clad silica type fibers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: How do I select the correct bridge voltage scaling jumper setting?\u003c\/strong\u003e\u003cbr\u003e\nA: Match your system PPT input voltage, which ranges from 140V rms to 1400V rms, to the corresponding jumper block configuration detailed in the hardware manual.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45372698525878,"sku":"IS200EDCFG1BAA","price":314.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IS200EDCFG1BAA.jpg?v=1787282375","url":"https:\/\/www.plcsparehub.com\/products\/is200edcfg1baa-general-electric-ex2100-exciter-dc-feedback-board-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}