{"product_id":"is200edcfg1aed-general-electric-ex2100-exciter-feedback-module-usa-stock","title":"IS200EDCFG1AED General Electric EX2100 Exciter Feedback Module USA Stock","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eIS200EDCFG1A IS200EDCFG1AED\u003c\/span\u003e Exciter DC Feedback Board\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eIS200EDCFG1A\u003c\/span\u003e\u003c\/strong\u003e is a high-speed exciter feedback interface board developed for the \u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eGE EX2100\u003c\/span\u003e\u003c\/strong\u003e excitation control platform.\u003c\/p\u003e\n\u003cp\u003eThe board measures field voltage and field current directly at the SCR bridge.\u003c\/p\u003e\n\u003cp\u003eIts fiber-optic communication architecture delivers excellent electrical isolation and strong noise immunity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eIS200EDCFG1AED\u003c\/span\u003e\u003c\/strong\u003e supports precise DC feedback processing in critical generator excitation environments.\u003c\/p\u003e\n\u003cp\u003eThe module combines shunt-based measurement technology with high-speed optical transmission performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Application Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eGE EX2100\u003c\/span\u003e\u003c\/strong\u003e excitation systems\u003c\/li\u003e\n\u003cli\u003eMeasures field current directly at the SCR bridge\u003c\/li\u003e\n\u003cli\u003eSupports field voltage feedback monitoring\u003c\/li\u003e\n\u003cli\u003eUses high-speed fiber-optic communication links\u003c\/li\u003e\n\u003cli\u003eProvides strong voltage isolation between control boards\u003c\/li\u003e\n\u003cli\u003eImproves signal integrity in high-noise industrial environments\u003c\/li\u003e\n\u003cli\u003eSupports long-distance optical signal transmission\u003c\/li\u003e\n\u003cli\u003eOptimized for generator excitation control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Industrial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eIS200EDCFG1A\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternate Model:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eIS200EDCFG1AED\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eEX2100\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Description:\u003c\/strong\u003e Exciter DC Feedback Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoard Type:\u003c\/strong\u003e Input\/Output Terminal Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Acronym:\u003c\/strong\u003e EDCF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Method:\u003c\/strong\u003e DC shunt measurement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Type:\u003c\/strong\u003e High-speed fiber optic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e ±24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Voltage Regulation:\u003c\/strong\u003e +15 VDC, -15 VDC, +5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Current Signal:\u003c\/strong\u003e Maximum 500 mV input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmplifier Output:\u003c\/strong\u003e -5 V to +5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Type:\u003c\/strong\u003e Plastic fiber and hard-clad silica fiber\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlastic Fiber Distance:\u003c\/strong\u003e Up to 10 meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSilica Fiber Distance:\u003c\/strong\u003e Up to 90 meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Fiber Bend Radius:\u003c\/strong\u003e 1.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Form:\u003c\/strong\u003e Form A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackward Compatibility:\u003c\/strong\u003e Not backward compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e High industrial EMC resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e USA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 3 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Reference:\u003c\/strong\u003e GEI-100464A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Processing Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe board measures field current through a DC shunt installed at the SCR bridge.\u003c\/p\u003e\n\u003cp\u003eLow-level current signals pass through a differential amplifier for stable conditioning.\u003c\/p\u003e\n\u003cp\u003eThe processed signal controls a voltage-controlled oscillator for feedback transmission.\u003c\/p\u003e\n\u003cp\u003eField voltage feedback is measured across the bridge negative terminal and shunt positive terminal.\u003c\/p\u003e\n\u003cp\u003eJumpered resistors provide multiple scaling selections for bridge voltage adaptation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFiber-Optic Communication Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides strong electrical isolation between boards\u003c\/li\u003e\n\u003cli\u003eReduces interference from high-voltage excitation environments\u003c\/li\u003e\n\u003cli\u003eSupports reliable long-distance signal transmission\u003c\/li\u003e\n\u003cli\u003eImproves feedback stability during generator operation\u003c\/li\u003e\n\u003cli\u003eMinimizes electrical noise influence on control signals\u003c\/li\u003e\n\u003cli\u003eSupports high-speed feedback synchronization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConnector Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJ16:\u003c\/strong\u003e External 24 VDC power input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP1:\u003c\/strong\u003e Field current shunt signal input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE1:\u003c\/strong\u003e Field voltage stab-on connection\u003c\/li\u003e\n\u003cli\u003eFiber-optic interfaces transmit current and voltage feedback data\u003c\/li\u003e\n\u003cli\u003eSingle PSOK LED confirms power supply operation status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain correct fiber bend radius during installation\u003c\/li\u003e\n\u003cli\u003eSeparate optical cables from power wiring routes\u003c\/li\u003e\n\u003cli\u003eVerify ±24 VDC supply stability before startup\u003c\/li\u003e\n\u003cli\u003eInspect shunt wiring polarity carefully\u003c\/li\u003e\n\u003cli\u003eUse clean optical connectors during commissioning\u003c\/li\u003e\n\u003cli\u003eCheck grounding continuity before energizing the system\u003c\/li\u003e\n\u003cli\u003eConfirm EISB board communication integrity after installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatible Equipment And Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eGE EX2100\u003c\/span\u003e\u003c\/strong\u003e excitation control systems\u003c\/li\u003e\n\u003cli\u003eGenerator excitation cabinets\u003c\/li\u003e\n\u003cli\u003eSCR bridge excitation assemblies\u003c\/li\u003e\n\u003cli\u003eIndustrial generator control platforms\u003c\/li\u003e\n\u003cli\u003ePower plant excitation monitoring systems\u003c\/li\u003e\n\u003cli\u003eGas turbine excitation infrastructure\u003c\/li\u003e\n\u003cli\u003eSteam turbine generator systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGenerator excitation feedback processing\u003c\/li\u003e\n\u003cli\u003eField voltage monitoring applications\u003c\/li\u003e\n\u003cli\u003eField current feedback measurement\u003c\/li\u003e\n\u003cli\u003eFiber-optic control signal transmission\u003c\/li\u003e\n\u003cli\u003eHigh-voltage isolation environments\u003c\/li\u003e\n\u003cli\u003ePower generation automation systems\u003c\/li\u003e\n\u003cli\u003eCritical excitation regulation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports SCR bridge feedback verification\u003c\/li\u003e\n\u003cli\u003eImproves excitation signal troubleshooting efficiency\u003c\/li\u003e\n\u003cli\u003eAllows fast optical communication diagnostics\u003c\/li\u003e\n\u003cli\u003eSupports voltage scaling verification procedures\u003c\/li\u003e\n\u003cli\u003eHelps identify unstable excitation feedback conditions\u003c\/li\u003e\n\u003cli\u003eImproves preventive maintenance planning\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eIS200EDCFG1A\u003c\/span\u003e\u003c\/strong\u003e performs exceptionally well in excitation systems requiring stable DC feedback acquisition.\u003c\/p\u003e\n\u003cp\u003eThe fiber-optic architecture significantly improves operational reliability inside high-voltage cabinets.\u003c\/p\u003e\n\u003cp\u003eEngineering teams value the board for strong electrical isolation and precise signal conditioning.\u003c\/p\u003e\n\u003cp\u003eThe module suits generator excitation environments requiring high-speed feedback communication.\u003c\/p\u003e\n\u003cp\u003eIts shunt-based measurement structure delivers reliable current monitoring performance during turbine operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePacking And Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong\u003e\u003cspan style=\"color: #cc0000;\"\u003eIS200EDCFG1A IS200EDCFG1AED\u003c\/span\u003e\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003eIndustrial anti-static protective packaging\u003c\/li\u003e\n\u003cli\u003eShock-resistant export-grade carton\u003c\/li\u003e\n\u003cli\u003eSecure connector protection packaging\u003c\/li\u003e\n\u003cli\u003eWorldwide shipping support available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty And Delivery Service\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Time:\u003c\/strong\u003e 24–48 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Services:\u003c\/strong\u003e FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Standard:\u003c\/strong\u003e Industrial export protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Delivery:\u003c\/strong\u003e Available worldwide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is fiber-optic communication important in excitation systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFiber optics improve electrical isolation and prevent interference from high-voltage excitation circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should engineers verify before selecting fiber type?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways confirm installation distance and cabinet routing conditions before choosing optical cable materials.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the module use shunt-based current measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShunt measurement provides stable and accurate field current monitoring at the SCR bridge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat installation issue commonly affects optical communication stability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExcessive cable bending often weakens optical transmission performance and signal reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat purchasing factor is most important for replacement projects?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify hardware form compatibility and confirm communication interface matching with the EISB board.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45133545832630,"sku":"IS200EDCFG1AED","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IS200EDCFG1AED.jpg?v=1779174472","url":"https:\/\/www.plcsparehub.com\/products\/is200edcfg1aed-general-electric-ex2100-exciter-feedback-module-usa-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}