{"product_id":"inict13a-abb-bailey-harmony-infi-net-computer-transfer-module-buy","title":"INICT13A ABB Bailey Harmony Infi-Net Computer Transfer Module Buy","description":"\u003ch3\u003e\u003cb\u003eNetwork Gateway Architecture: \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eINICT13A\u003c\/b\u003e\u003c\/font\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eABB Bailey INICT13A\u003c\/b\u003e\u003c\/font\u003e (referenced as \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eICT13A\u003c\/b\u003e\u003c\/font\u003e and forward-compatible with the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSPICT13A\u003c\/b\u003e\u003c\/font\u003e series) is an \u003cb\u003eInfi-Net to Computer Transfer Module (ICI)\u003c\/b\u003e built for the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eABB Harmony\u003c\/b\u003e\u003c\/font\u003e rack hardware architecture. Acting as a deterministic protocol bridge, this module manages bidirectional real-time data transfer and command execution between an \u003cb\u003eInfi-Net\u003c\/b\u003e process control highway and external host computers, engineering workstations, or SCADA nodes. It pairs directly with an \u003cb\u003eINNIS21\u003c\/b\u003e Network Interface Slave via the dedicated I\/O expander bus to eliminate communication bottlenecks in distributed control systems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eHardware, Electrical \u0026amp; Communication Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eDesigned for continuous operation inside standard \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eHarmony\u003c\/b\u003e\u003c\/font\u003e Module Mounting Units (MMUs), the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eINICT13A\u003c\/b\u003e\u003c\/font\u003e consolidates backplane power regulation and high-speed host interfaces:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cb\u003eSubsystem\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eEngineering Parameter\u003c\/b\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cb\u003eRated Value \/ Technical Detail\u003c\/b\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eIdentification\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eManufacturer \u0026amp; Primary Model\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eABB\u003c\/b\u003e\u003c\/font\u003e (Bailey Controls) \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eINICT13A\u003c\/b\u003e\u003c\/font\u003e \/ \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eICT13A\u003c\/b\u003e\u003c\/font\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eIdentification\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eProduct Family \u0026amp; Succession\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eHarmony Rack HW\u003c\/b\u003e\u003c\/font\u003e (Cross-referenced to \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eSPICT13A\u003c\/b\u003e\u003c\/font\u003e)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eHost Interfaces\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eExternal Communication Ports\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003eRS-232-C\u003c\/b\u003e (via \u003cb\u003eNTMP01\u003c\/b\u003e termination unit) \u0026amp; Front-Panel \u003cb\u003e50-Pin SCSI\u003c\/b\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eSystem Backplane\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eInternal Bus Architecture\u003c\/td\u003e\n      \u003ctd\u003eDedicated \u003cb\u003eI\/O Expander Bus\u003c\/b\u003e (pairs directly with \u003cb\u003eINNIS21\u003c\/b\u003e module)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003ePower \u0026amp; Thermal\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupply Voltage \u0026amp; Output Rating\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e24 VDC\u003c\/b\u003e backplane input | \u003cb\u003e5 VDC, 2 A\u003c\/b\u003e output | \u003cb\u003e3 W\u003c\/b\u003e power dissipation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eEnvironmental\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e0°C to +55°C\u003c\/b\u003e continuous industrial cabinet rating\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eMechanical\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eDimensions \u0026amp; Shipping Weight\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cb\u003e14.2 × 10.6 × 2.9 in\u003c\/b\u003e (H × W × L) | \u003cb\u003e0.658 kg\u003c\/b\u003e gross (0.25–1.1 kg range)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cb\u003eLogistics\u003c\/b\u003e\u003c\/td\u003e\n      \u003ctd\u003eCustoms Tariff \u0026amp; Order Unit\u003c\/td\u003e\n      \u003ctd\u003eHS Code \u003cb\u003e8517620050\u003c\/b\u003e | Minimum Order: \u003cb\u003e1 EA\u003c\/b\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eRack Integration \u0026amp; Host Cabling Protocol\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eAdjacent Slot Pairing:\u003c\/b\u003e Seat the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eINICT13A\u003c\/b\u003e\u003c\/font\u003e immediately adjacent to its companion \u003cb\u003eINNIS21\u003c\/b\u003e module inside the \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eHarmony\u003c\/b\u003e\u003c\/font\u003e card cage so the backplane I\/O expander bus establishes uninterrupted parallel data exchange.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eHost Interface Selection:\u003c\/b\u003e Route serial \u003cb\u003eRS-232-C\u003c\/b\u003e cables through the rear \u003cb\u003eNTMP01\u003c\/b\u003e termination unit for standard workstation links, or utilize the front-panel \u003cb\u003e50-pin SCSI\u003c\/b\u003e connector when high-throughput parallel host transfers are required.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDIP Switch \u0026amp; Firmware Alignment:\u003c\/b\u003e Match the onboard address and baud-rate DIP switch banks precisely to the existing node configuration before sliding the module into an energized backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eDiagnostic \u0026amp; Field Maintenance Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eFront-Panel Status Verification:\u003c\/b\u003e Inspect the faceplate diagnostic LEDs upon power-up to confirm successful self-test completion and active handshaking between the \u003cb\u003eINNIS21\u003c\/b\u003e slave and host computer port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eSCSI \u0026amp; Termination Inspection:\u003c\/b\u003e Periodically check the \u003cb\u003e50-pin SCSI\u003c\/b\u003e latch mechanism and rear \u003cb\u003eNTMP01\u003c\/b\u003e ribbon cable seating during scheduled plant turnarounds to prevent intermittent framing errors caused by cabinet vibration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eThermal Airflow Management:\u003c\/b\u003e Keep adjacent rack slots free of loose wiring harnesses to preserve natural convection cooling across the \u003cb\u003e0°C to +55°C\u003c\/b\u003e operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eTarget Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eDCS-to-HMI \/ Historian Gateways:\u003c\/b\u003e Real-time process data acquisition linking \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eABB Bailey\u003c\/b\u003e\u003c\/font\u003e INFI 90 \/ Harmony control loops to operator consoles, engineering stations, and plant historians.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003ePower \u0026amp; Process Automation:\u003c\/b\u003e Fossil and combined-cycle power generation, pulp and paper mills, chemical refineries, and metals processing facilities running legacy \u003cb\u003eInfi-Net\u003c\/b\u003e loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eScope of Delivery\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003e1 ×\u003c\/b\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eABB Bailey\u003c\/b\u003e\u003c\/font\u003e \u003cfont color=\"#0056b3\"\u003e\u003cb\u003eINICT13A\u003c\/b\u003e\u003c\/font\u003e (\u003cfont color=\"#0056b3\"\u003e\u003cb\u003eICT13A\u003c\/b\u003e\u003c\/font\u003e) Infi-Net to Computer Transfer Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eField Engineering FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: How does the INICT13A relate to the ICT13A and SPICT13A part numbers during spare parts procurement?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: INICT13A and ICT13A identify the classic Harmony\/INFI 90 Infi-Net to Computer Transfer Module assembly, while SPICT13A represents ABB's standard catalog replacement designation for the same functional hardware family. Verify your rack backplane and firmware revision when ordering.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: Can the INICT13A communicate directly onto the Infi-Net ring without an INNIS21 module?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: No, the INICT13A handles host computer protocol conversion (RS-232-C or SCSI) and relies on an adjacent INNIS21 Network Interface Slave over the local I\/O expander bus to physically interface with the Infi-Net communication loop.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: When should field engineers use the NTMP01 termination unit versus the front-panel 50-pin SCSI port?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: Use the rear NTMP01 termination unit for standard RS-232-C serial connections to engineering workstations or modems, and reserve the front 50-pin SCSI port for high-speed parallel computer interfaces such as legacy VAX, Alpha, or PCI-SCSI host adapters.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: What diagnostic checks are recommended if host polling times out after hot-swapping the module?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: First confirm that the onboard DIP switches for node address, parity, and baud rate match the replaced unit exactly. Next, verify that the module is firmly seated onto the 24 VDC backplane pins and check the ribbon cable between the MMU backplane and the NTMP01 unit.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n    \u003cp\u003e\u003cb\u003eQ: Does the INICT13A require an external 5 VDC power supply inside the Harmony cabinet?\u003c\/b\u003e\u003c\/p\u003e\n    \u003cp\u003eA: No, the module draws 24 VDC directly from the Harmony rack backplane and regulates its own 5 VDC (2 A) logic power internally while dissipating only 3 W of heat.\u003c\/p\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68078352105654,"sku":"INICT13A","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/INICT13A-1.jpg?v=1794813051","url":"https:\/\/www.plcsparehub.com\/products\/inict13a-abb-bailey-harmony-infi-net-computer-transfer-module-buy","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}