{"product_id":"imaso11-abb-analog-output-module-infi-90-open-14-point","title":"IMASO11 ABB Analog Output Module | INFI 90 OPEN 14-Point","description":"\u003ch2\u003e\u003cstrong\u003eABB IMASO11 INFI 90 OPEN Analog Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB IMASO11\u003c\/strong\u003e is a 14-channel analog output module designed for the \u003cstrong\u003eINFI 90 OPEN\u003c\/strong\u003e distributed control system. It converts digital control data into analog signals for field-level process regulation.\u003c\/p\u003e\n\u003cp\u003eEach output supports \u003cstrong\u003e1–5 VDC or 4–20 mA\u003c\/strong\u003e operation. The module provides 10-bit digital-to-analog conversion, defined output accuracy, and load limits for voltage and current applications.\u003c\/p\u003e\n\u003cp\u003eEngineers can use the IMASO11 to interface controller output commands with compatible final control elements and analog signal devices. Its LED indicators also help identify communication status and bus-related faults during commissioning and maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Output Channel Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct model\u003c\/td\u003e\n\u003ctd\u003eIMASO11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem family\u003c\/td\u003e\n\u003ctd\u003eINFI 90 OPEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule type\u003c\/td\u003e\n\u003ctd\u003eAnalog output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of outputs\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput signal modes\u003c\/td\u003e\n\u003ctd\u003e4–20 mA and 1–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A resolution\u003c\/td\u003e\n\u003ctd\u003e10 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage output accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent output accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Analog Signal Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IMASO11 supports two analog signal formats for different control-system interfaces. Select the appropriate operating mode according to the connected field device and system configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Parameter\u003c\/th\u003e\n\u003cth\u003eVoltage Mode\u003c\/th\u003e\n\u003cth\u003eCurrent Mode\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal range\u003c\/td\u003e\n\u003ctd\u003e1–5 VDC\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A resolution\u003c\/td\u003e\n\u003ctd\u003e10 bits\u003c\/td\u003e\n\u003ctd\u003e10 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput accuracy\u003c\/td\u003e\n\u003ctd\u003e≤0.15%\u003c\/td\u003e\n\u003ctd\u003e≤0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad requirement\u003c\/td\u003e\n\u003ctd\u003e22 kΩ minimum\u003c\/td\u003e\n\u003ctd\u003e750 Ω maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage-mode applications require a load impedance of at least 22 kΩ.\u003c\/li\u003e\n\u003cli\u003eCurrent-mode applications must keep the total loop load at or below 750 Ω.\u003c\/li\u003e\n\u003cli\u003eCheck cable resistance and connected instrument impedance when calculating the output load.\u003c\/li\u003e\n\u003cli\u003eVerify the selected signal mode before connecting the field wiring.\u003c\/li\u003e\n\u003cli\u003eUse the specified accuracy values when evaluating control-loop performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Output Protection and Electrical Safety\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current limiting\u003c\/td\u003e\n\u003ctd\u003eProvided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003eProvided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output current limit\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput overvoltage category\u003c\/td\u003e\n\u003ctd\u003eCategory III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference standard\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA S82.01-1994\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module includes output current limiting and short-circuit protection. The specified nominal current limit is 50 mA.\u003c\/p\u003e\n\u003cp\u003eThe output circuit uses Overvoltage Category III classification under ANSI\/ISA S82.01-1994. Follow the applicable cabinet wiring and installation requirements when integrating the module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Power Supply and Consumption Budget\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IMASO11 requires multiple DC supply rails. The +24 VDC supply comes from the termination unit or termination module. Check all supply rails before commissioning.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply Rail\u003c\/th\u003e\n\u003cth\u003eVoltage Tolerance\u003c\/th\u003e\n\u003cth\u003eTypical Current\u003c\/th\u003e\n\u003cth\u003eTypical Power Dissipation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e+5 VDC\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+15 VDC\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-15 VDC\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003ctd\u003e90 mA\u003c\/td\u003e\n\u003ctd\u003e1.75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 VDC\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003ctd\u003e310 mA\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply classification:\u003c\/strong\u003e Category I for power circuits, according to ANSI\/ISA S82.01-1994.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning recommendation:\u003c\/strong\u003e Measure each supply rail under operating conditions. Confirm polarity, voltage tolerance, and termination-unit supply capacity before enabling the module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Environmental Operating Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Parameter\u003c\/th\u003e\n\u003cth\u003eOperating Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity up to 55°C\u003c\/td\u003e\n\u003ctd\u003e0% to 95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity at 70°C\u003c\/td\u003e\n\u003ctd\u003e0% to 45%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003eI, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir quality\u003c\/td\u003e\n\u003ctd\u003eNoncorrosive environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMaintain the module within its specified temperature and humidity limits. Prevent condensation and exposure to corrosive atmospheres. Confirm cabinet ventilation and installation conditions during system maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Status LED Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwo status LEDs indicate module power, enablement, and communication conditions. Use their combined states to identify the operating condition.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRed LED\u003c\/th\u003e\n\u003cth\u003eGreen LED\u003c\/th\u003e\n\u003cth\u003eModule Status\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eNo power or module not enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eEnabled and communicating with control module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eOFF\u003c\/td\u003e\n\u003ctd\u003eBus fault timer error or communication timeout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eON\u003c\/td\u003e\n\u003ctd\u003eNot an allowed operating state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField troubleshooting sequence:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eCheck the module supply rails if both LEDs remain OFF.\u003c\/li\u003e\n\u003cli\u003eConfirm that the control system enables the module.\u003c\/li\u003e\n\u003cli\u003eInspect the communication path if the red LED indicates a timeout.\u003c\/li\u003e\n\u003cli\u003eCheck controller status and system bus conditions.\u003c\/li\u003e\n\u003cli\u003eAfter correcting the fault, verify that the green LED turns ON and the red LED turns OFF.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | CE Compliance and Certification Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen installed in an INFI 90 OPEN cabinet, the product complies with the following declared EMC and safety requirements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 89\/336\/EEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Directive:\u003c\/strong\u003e 73\/23\/EEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 50082-2:\u003c\/strong\u003e Generic Immunity Standard, Industrial Environment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 50081-2:\u003c\/strong\u003e Generic Emission Standard, Industrial Environment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 61010-1:\u003c\/strong\u003e Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertification details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA: Certified for process control equipment in ordinary, nonhazardous locations.\u003c\/li\u003e\n\u003cli\u003eNonincendive application categories: Class I, Division 2, Groups A, B, C, D.\u003c\/li\u003e\n\u003cli\u003eNonincendive application categories: Class II, Division 2, Groups F, G.\u003c\/li\u003e\n\u003cli\u003eFactory Mutual (FM): Listed as pending in the supplied technical information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the exact approval status and installation conditions against the product nameplate and applicable certification documentation. Do not treat the pending FM status as an issued approval.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IMASO11.png?v=1795162206\" alt=\"\"\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68112923623606,"sku":"IMASO11","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IMASO11-1.jpg?v=1795162206","url":"https:\/\/www.plcsparehub.com\/products\/imaso11-abb-analog-output-module-infi-90-open-14-point","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}