{"product_id":"ic697mdl241-ge-fanuc-series-90-70-discrete-input-module-in-stock","title":"IC697MDL241 GE Fanuc Series 90-70 Discrete Input Module In Stock","description":"\u003ch3\u003e\u003cstrong\u003eProduct Summary \u0026amp; Core Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC697MDL241\u003c\/strong\u003e\u003c\/span\u003e functions as a high-voltage input interface for the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSeries 90-70\u003c\/strong\u003e\u003c\/span\u003e PLC system.\u003c\/p\u003e\n\u003cp\u003eThis \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDiscrete Input Module\u003c\/strong\u003e\u003c\/span\u003e features 16 fully isolated input points engineered for 240V AC industrial control circuits.\u003c\/p\u003e\n\u003cp\u003eEach isolated input channel operates across independent AC supply phases without cross-channel electrical interference.\u003c\/p\u003e\n\u003cp\u003eIntegrated capacitive input circuitry reduces internal thermal dissipation, enhancing component lifespan and long-term chassis reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring a control retrofitting project at a power generation facility, high ambient cabinet temperatures caused repeated thermal faults in legacy resistance-based input cards.\u003c\/p\u003e\n\u003cp\u003eInstalling the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC697MDL241\u003c\/strong\u003e\u003c\/span\u003e solved the thermal breakdown due to its capacitive input design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\u003c\/span\u003e \/ GE Intelligent Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC697MDL241\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-series-90-30-series-90-70\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSeries 90-70\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e PLC Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eDiscrete Input Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 Volts AC (60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Point Density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Channels (Fully Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Filter Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA typical (20 mA maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Leakage Current Handling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSinks up to 5 mA leakage current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 Amps from 5V bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximity Switch Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with 2-wire and 3-wire electronic proximity sensors (IEC reactive standards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Features \u0026amp; Mechanical Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHardware Configuration \u0026amp; Mechanical Keying:\n\u003cul\u003e\n\u003cli\u003eSoftware-configurable I\/O mapping eliminates physical DIP switches or jumpers.\u003c\/li\u003e\n\u003cli\u003eMechanical keying prevents accidental insertion into wrong chassis slots during maintenance.\u003c\/li\u003e\n\u003cli\u003eProgramming software manages I\/O allocation via SNP or Ethernet TCP\/IP interface ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eField Device Compatibility:\n\u003cul\u003e\n\u003cli\u003eInterfaces with industrial pushbuttons, selector switches, and limit switches.\u003c\/li\u003e\n\u003cli\u003eSupports high-voltage 240V AC 2-wire and 3-wire solid-state proximity sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy Duty Power Generation \u0026amp; Distribution Plants:\n\u003cul\u003e\n\u003cli\u003eMonitors isolated 240V AC auxiliary contact feedback from high-voltage breakers and switchgear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaterial Handling \u0026amp; Conveyance Systems:\n\u003cul\u003e\n\u003cli\u003eProcesses limit switch signals across long-distance plant runs prone to electrical noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePumping \u0026amp; Water Treatment Facilities:\n\u003cul\u003e\n\u003cli\u003eInterfaces multi-phase float level switches and motor starter status contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLogic-side optical LEDs mounted at the top of the card display individual ON\/OFF point status.\u003c\/li\u003e\n\u003cli\u003eCapacitive filter network filters out transient line spikes and mechanical contact bounce.\u003c\/li\u003e\n\u003cli\u003eSoftware-driven backplane status reporting alerts the CPU to module missing or bus failure conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty Clause \u0026amp; Dispatch Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Month Comprehensive Warranty:\u003c\/strong\u003e Full coverage for hardware functionality and operational performance.\u003c\/li\u003e\n\u003cli\u003eRapid Shipping: Orders packed and dispatched globally within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003eCarrier Services: Worldwide express shipping via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the \u003cspan style=\"color: #0056b3;\"\u003eIC697MDL241\u003c\/span\u003e require physical jumper adjustments during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Software handles all channel mapping and configuration settings without hardware DIP switches.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the 20ms input filter time benefit high-voltage AC field wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It prevents false input triggers caused by line noise and contact chatter on long cable runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can individual channels on the \u003cspan style=\"color: #0056b3;\"\u003eIC697MDL241\u003c\/span\u003e operate from different AC supply phases?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Channel-to-channel isolation allows each point to connect to separate 240V AC phases safely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What causes 2-wire proximity sensors to remain ON falsely on standard AC input modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: High off-state leakage current. This module sinks up to 5mA off-state leakage, preventing false ON states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What procedure ensures safe replacement of this card in a live rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: De-energize field wiring connections and utilize the mechanical keying slot to seat the replacement card correctly.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014015279286,"sku":"IC697MDL241","price":122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC697MDL241.jpg?v=1787888324","url":"https:\/\/www.plcsparehub.com\/products\/ic697mdl241-ge-fanuc-series-90-70-discrete-input-module-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}