{"product_id":"ic697cmm741-ge-fanuc-series-90-70-plc-ethernet-lan-interface","title":"IC697CMM741 GE Fanuc Series 90-70 PLC Ethernet LAN Interface","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a73e8;\"\u003eGE Fanuc IC697CMM741\u003c\/strong\u003e is an Ethernet Controller for the \u003cstrong style=\"color: #1a73e8;\"\u003eSeries 90-70 PLC\u003c\/strong\u003e platform.\u003c\/p\u003e\n\u003cp\u003eIt provides a direct communication interface between PLC systems and Ethernet local area networks (LANs). The module supports TCP\/IP and MMS\/OSI communication environments. It connects the PLC to IEEE 802.3 CSMA\/CD Ethernet networks through an external transceiver.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC697CMM741\u003c\/strong\u003e occupies one slot in the Series 90-70 rack. Its battery-backed RAM stores communication software and supports software retention during power interruptions. Under specified conditions, the memory retains its contents for at least six months.\u003c\/p\u003e\n\u003cp\u003eThe controller also includes ROM-based firmware for basic operations, configuration, and diagnostic functions. Three onboard LEDs help engineers monitor communication and module status.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIC697CMM741\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet Controller \/ LAN Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLC-to-Ethernet Network Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 CSMA\/CD Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP and MMS\/OSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAM and ROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRAM Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery-backed memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Retention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt least 6 months under specified conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal transceiver cable or AUI cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Occupancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Series 90-70 rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Series 90-70 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eCore Features and Engineering Advantages\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Network Integration:\u003c\/strong\u003e Connects Series 90-70 PLCs to compatible Ethernet LAN infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Protocol Communication:\u003c\/strong\u003e Supports TCP\/IP and MMS\/OSI communication software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery-Backed RAM:\u003c\/strong\u003e Preserves stored communication software during power interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eROM-Based Firmware:\u003c\/strong\u003e Provides fundamental operating, configuration, and diagnostic functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Slot Installation:\u003c\/strong\u003e Requires only one rack slot for installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Transceiver Connection:\u003c\/strong\u003e Uses a standard 15-pin D-type interface for Ethernet connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Status Monitoring:\u003c\/strong\u003e Provides three indicators for basic module status checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Management:\u003c\/strong\u003e Supports communication software loading and upgrading through RAM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCommunication Architecture and Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC697CMM741\u003c\/strong\u003e provides an Ethernet communication path for Series 90-70 control systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnects PLC systems to industrial Ethernet LAN infrastructure.\u003c\/li\u003e\n\u003cli\u003eSupports TCP\/IP communication with compatible network devices.\u003c\/li\u003e\n\u003cli\u003eProvides MMS\/OSI communication capabilities for supported systems.\u003c\/li\u003e\n\u003cli\u003eEnables PLC data exchange with compatible supervisory and programming systems.\u003c\/li\u003e\n\u003cli\u003eSupports network-based diagnostics and station management applications.\u003c\/li\u003e\n\u003cli\u003eIntegrates Series 90-70 controllers into plant-level communication architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSwitch off the PLC rack power before installation.\u003c\/li\u003e\n\u003cli\u003eVerify the rack model and available module slot.\u003c\/li\u003e\n\u003cli\u003eCheck the module connector and board condition.\u003c\/li\u003e\n\u003cli\u003eInsert the \u003cstrong\u003eIC697CMM741\u003c\/strong\u003e into a compatible Series 90-70 rack slot.\u003c\/li\u003e\n\u003cli\u003eSecure the module according to the rack installation procedure.\u003c\/li\u003e\n\u003cli\u003eConnect the external transceiver using a compatible 15-pin cable.\u003c\/li\u003e\n\u003cli\u003eVerify the Ethernet transceiver and network cable connections.\u003c\/li\u003e\n\u003cli\u003eRestore power and inspect the three status LEDs.\u003c\/li\u003e\n\u003cli\u003eConfigure the communication parameters using compatible engineering software.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Note:\u003c\/strong\u003e Follow the applicable GE Fanuc hardware manuals. Confirm rack compatibility and power requirements before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCommissioning, Diagnostics and Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Inspection:\u003c\/strong\u003e Check rack seating, connector condition, and cable connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Diagnostics:\u003c\/strong\u003e Observe all three indicators during startup and network operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Testing:\u003c\/strong\u003e Verify TCP\/IP or MMS\/OSI communication with the intended network devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Verification:\u003c\/strong\u003e Confirm the correct communication software and configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Maintenance:\u003c\/strong\u003e Check the backup battery according to the maintenance schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Inspection:\u003c\/strong\u003e Examine transceiver connections and Ethernet cabling regularly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Isolation:\u003c\/strong\u003e Check power, rack seating, network connections, and software configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEngineers should verify battery condition before extended power interruptions. Do not rely solely on the specified six-month retention period when planning maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility Information\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePLC Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Series 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible Series 90-70 rack with one available slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 CSMA\/CD Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible TCP\/IP and MMS\/OSI software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-pin D-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible external transceiver and AUI cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility Note:\u003c\/strong\u003e Verify the PLC CPU, rack configuration, firmware, communication software, and network transceiver before ordering. Confirm the required network architecture for your application.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCertifications and Compliance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe available product information does not specify individual regulatory approvals for the \u003cstrong\u003eIC697CMM741\u003c\/strong\u003e. Please confirm applicable certifications and compliance requirements through the product nameplate and manufacturer documentation before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePackaging and Supply\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × GE Fanuc IC697CMM741 Ethernet Controller Module\u003c\/li\u003e\n\u003cli\u003eProtective packaging for transportation\u003c\/li\u003e\n\u003cli\u003eProduct identification and model verification\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNew \u0026amp; Original in Factory Packing\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFactory Warranty: 12 Months\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eShipping options: FedEx, UPS, and DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExternal transceiver cables, AUI cables, and other accessories are not included unless specifically confirmed in the order.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main function of the GE Fanuc IC697CMM741?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC697CMM741 provides Ethernet communication for GE Fanuc Series 90-70 PLC systems. It connects the controller to compatible LAN devices through an external transceiver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the IC697CMM741 retain its communication software after a power failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Its battery-backed RAM preserves stored software for at least six months under specified conditions. Actual retention depends on battery condition and operating history.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers check when the module cannot communicate with the Ethernet network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart with rack seating, module power, and LED indications. Then inspect the 15-pin connection, transceiver, AUI cable, and network configuration. Verify the communication software and protocol settings before replacing hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What information should buyers confirm before ordering the IC697CMM741?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the complete model number, Series 90-70 rack compatibility, and required Ethernet connection. Also confirm the communication protocol, transceiver type, and software requirements. Matching these details helps prevent commissioning delays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can the IC697CMM741 directly connect to a standard Ethernet network cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot through a standard RJ45 connection based on the specified interface. The module uses a 15-pin D-type connector and requires a compatible external transceiver or AUI connection. Confirm the network hardware before selecting cables.\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC697CMM741.png?v=1795412243\" alt=\"\"\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013994569910,"sku":"IC697CMM741","price":122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC697CMM741-1.jpg?v=1795412243","url":"https:\/\/www.plcsparehub.com\/products\/ic697cmm741-ge-fanuc-series-90-70-plc-ethernet-lan-interface","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}