{"product_id":"ic697cmm711-ge-fanuc-series-90-70-communications-coprocessor","title":"IC697CMM711 GE Fanuc Series 90-70 Communications Coprocessor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC697CMM711\u003c\/span\u003e\u003c\/strong\u003e is a high-performance communication coprocessor module engineered for the GE Fanuc Series 90-70 PLC platform. Equipped with a dedicated 12 MHz 80C186 microprocessor, this module offloads complex serial processing from the main CPU to ensure deterministic logic execution. It features two independent 25-pin D-shell ports that support versatile multi-protocol integration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc \/ Emerson Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC697CMM711\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Series 90-70 PAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e Onboard 12 MHz 80C186\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e Two (2) RS-232 \/ RS-422 \/ RS-485 configurable ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Connection:\u003c\/strong\u003e 25-pin D-shell female connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rate Support:\u003c\/strong\u003e 300, 600, 1200, 2400, 4800, 9600, and 19200 bps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Load:\u003c\/strong\u003e 700 mA at 5VDC bus voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Occupancy:\u003c\/strong\u003e Single-slot width in Series 90-70 CPU baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e 3 Status LEDs (Module OK, Port 1, Port 2) and initialization pushbutton\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Logic \u0026amp; Protocol Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC697CMM711\u003c\/span\u003e\u003c\/strong\u003e [Communication Coprocessor Engine]\n\u003cul\u003e\n\u003cli\u003e└── \u003cstrong\u003eCCM Protocol\u003c\/strong\u003e [Master, Slave, and Peer-to-Peer data exchange]\u003c\/li\u003e\n\u003cli\u003e└── \u003cstrong\u003eSNP \/ SNPX Protocol\u003c\/strong\u003e [Master and Slave modes for GE networking]\u003c\/li\u003e\n\u003cli\u003e└── \u003cstrong\u003eModbus RTU\u003c\/strong\u003e [Slave-only mode for third-party SCADA\/HMI links]\u003c\/li\u003e\n\u003cli\u003e└── \u003cstrong\u003eSoft Configuration\u003c\/strong\u003e [Programmable via VersaPro or Proficy Machine Edition]\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility \u0026amp; Industrial Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Architecture:\u003c\/strong\u003e Fully compatible with VME standard C.1 backplanes and 90-70 racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandability:\u003c\/strong\u003e Supports multiple \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC697CMM711\u003c\/span\u003e\u003c\/strong\u003e units in a single rack for high-density serial comms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero Maintenance:\u003c\/strong\u003e Solid-state design requires no batteries, jumpers, or physical DIP switches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Robust electromagnetic shielding for reliable operation in high-noise plant environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios \u0026amp; Diagnostic Power\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHMI\/SCADA Gateway:\u003c\/strong\u003e Provides high-speed data piping to industrial operator interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Drop Networking:\u003c\/strong\u003e Facilitates RS-485 communication with downstream field devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy System Support:\u003c\/strong\u003e Essential for maintaining communication in aging Series 90-70 infrastructures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e Integrated processor monitors port activity and module health in real-time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC697CMM711\u003c\/span\u003e\u003c\/strong\u003e remains a critical asset for engineers managing legacy Series 90-70 architectures. Its primary advantage is the dedicated 80C186 silicon, which ensures that heavy serial traffic does not jitter the PLC scan cycle. While officially discontinued by the OEM, we provide this module in premium condition to ensure your facility avoids downtime. It is particularly effective for peer-to-peer data sharing where deterministic timing is a non-negotiable requirement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Original equipment in factory-standard protective packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month comprehensive warranty included for peace of mind.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Professional testing and dispatch within 24-48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpress Shipping:\u003c\/strong\u003e Global priority delivery via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eExpert FAQ \u0026amp; Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDoes the IC697CMM711 support Modbus Master mode?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNo, the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC697CMM711\u003c\/span\u003e\u003c\/strong\u003e is restricted to Modbus Slave mode only for RTU protocols.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan I configure the ports using physical switches?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNo, this module uses \"Soft Configuration\" only; settings must be downloaded from the programming software.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIs it safe to install this module while the PLC is powered?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eNegative. Power must be removed from the baseplate to prevent arcing and potential damage to the VME pins.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eField Experience Tip:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIf communication fails after a software update, use the front-panel pushbutton to re-initialize the module’s serial buffers.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBuying Advice:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eVerify your cabling pinouts; the 25-pin D-shell ports often require specific adapters when converting to standard 9-pin RS-232.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013985820854,"sku":"IC697CMM711","price":133.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC697CMM711.jpg?v=1775721805","url":"https:\/\/www.plcsparehub.com\/products\/ic697cmm711-ge-fanuc-series-90-70-communications-coprocessor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}