{"product_id":"ic697alg230-emerson-ge-fanuc-plc-analog-input-converter-module","title":"IC697ALG230 Emerson GE Fanuc PLC Analog Input Converter Module","description":"\u003ch3\u003e\u003cb\u003eProduct Introduction\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eGE Fanuc IC697ALG230\u003c\/b\u003e\u003c\/span\u003e Base Converter Module belongs to the \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eSeries 90-70 PLC\u003c\/b\u003e\u003c\/span\u003e platform.\u003c\/p\u003e\n\u003cp\u003eIt provides high-accuracy analog signal conversion for industrial control systems.\u003c\/p\u003e\n\u003cp\u003eThe module supports eight differential analog input channels.\u003c\/p\u003e\n\u003cp\u003eEach channel supports voltage or current signal configuration.\u003c\/p\u003e\n\u003cp\u003eThe module works with \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC697ALG440\u003c\/b\u003e\u003c\/span\u003e voltage expanders and \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC697ALG441\u003c\/b\u003e\u003c\/span\u003e current expanders.\u003c\/p\u003e\n\u003cp\u003eThe system supports scalable analog measurement applications.\u003c\/p\u003e\n\u003cp\u003eEngineers use this module for process monitoring and automation control.\u003c\/p\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC697ALG230\u003c\/b\u003e\u003c\/span\u003e uses differential wiring technology.\u003c\/p\u003e\n\u003cp\u003eThis design improves signal stability in industrial environments.\u003c\/p\u003e\n\u003cp\u003eIt reduces measurement errors caused by electrical noise.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB Review shows strong field value for this module.\u003c\/p\u003e\n\u003cp\u003eEngineers often select it for reliable analog acquisition projects.\u003c\/p\u003e\n\u003cp\u003eA typical field example involves monitoring pressure transmitters in a refinery unit.\u003c\/p\u003e\n\u003cp\u003eThe module receives 4-20 mA signals from transmitters.\u003c\/p\u003e\n\u003cp\u003eThe PLC system then processes real-time process data.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eParameter\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Current support under Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-series-90-30-series-90-70\"\u003e\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eSeries 90-70 PLC\u003c\/b\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC697ALG230\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Base Converter Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 differential analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current input and -10 VDC to +10 VDC voltage input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eVoltage: -10 VDC to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eCurrent: 0 mA to 22.5 mA, default 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit analog input resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e2.4 ms to 2.8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eFast analog sampling with channel filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e0.1% accuracy response within 67 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e0.5% accuracy response within 51 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e1.0% accuracy response within 42 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e5.0% accuracy response within 30 milliseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01% full scale and ±0.02% value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05% full scale and ±0.1% value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±0.02% full scale across measurement range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003eVoltage: typical ±5 PPM\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003eVoltage maximum ±15 PPM\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003eCurrent maximum ±30 PPM\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated at 10 volts ±2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e0.8 A at +5 VDC, approximately 4 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003e40-pin removable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Method\u003c\/td\u003e\n\u003ctd\u003eDifferential wiring configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Capability\u003c\/td\u003e\n\u003ctd\u003eDesigned for industrial PLC control environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Protection\u003c\/td\u003e\n\u003ctd\u003eOpto-isolation and channel filtering improve interference resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eCore Technical Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eEight-channel differential analog acquisition\u003c\/b\u003e supports flexible signal monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e16-bit resolution\u003c\/b\u003e provides accurate process measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndividual channel configuration\u003c\/b\u003e simplifies engineering setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLow-pass filtering\u003c\/b\u003e improves signal quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOptical isolation\u003c\/b\u003e protects PLC backplane communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExpansion capability\u003c\/b\u003e supports larger analog systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility Information\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCompatible Product\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDescription\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/products\/ic697alg440-current-expander-module-ge-fanuc\"\u003e\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC697ALG440\u003c\/b\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage Expander Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/products\/ic697alg441-analog-input-expander-ge-fanuc-16-channel\"\u003e\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC697ALG441\u003c\/b\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Expander Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eSeries 90-70 PLC\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eMain PLC platform compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe base module supports up to seven expander modules.\u003c\/p\u003e\n\u003cp\u003eThe complete system can reach up to 120 analog inputs.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module into the compatible Series 90-70 rack.\u003c\/li\u003e\n\u003cli\u003eConfirm PLC power isolation before installation.\u003c\/li\u003e\n\u003cli\u003eConnect field signals through the removable terminal block.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for sensitive analog signals.\u003c\/li\u003e\n\u003cli\u003eVerify correct voltage and current channel settings.\u003c\/li\u003e\n\u003cli\u003eInstall expander modules through the expansion interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDifferential wiring requires two reference wires per input channel.\u003c\/p\u003e\n\u003cp\u003eThis wiring method improves EMI resistance in industrial locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCommissioning and Maintenance Advantages\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe configuration software simplifies channel parameter setup.\u003c\/li\u003e\n\u003cli\u003eEngineers can adjust scaling values through PLC logic.\u003c\/li\u003e\n\u003cli\u003eChannel diagnostics support troubleshooting activities.\u003c\/li\u003e\n\u003cli\u003eCPU alarms provide abnormal condition notifications.\u003c\/li\u003e\n\u003cli\u003eFault reporting improves maintenance efficiency.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight highlights practical maintenance benefits.\u003c\/p\u003e\n\u003cp\u003eField technicians often check signal range first during commissioning.\u003c\/p\u003e\n\u003cp\u003eFor example, a 4-20 mA loop test quickly identifies wiring issues.\u003c\/p\u003e\n\u003cp\u003eThe module allows engineers to compare expected and actual values.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capability\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChannel-level fault reporting supports fast troubleshooting.\u003c\/li\u003e\n\u003cli\u003eInput monitoring helps detect abnormal signals.\u003c\/li\u003e\n\u003cli\u003eConfiguration data assists system verification.\u003c\/li\u003e\n\u003cli\u003eSignal filtering reduces unstable readings.\u003c\/li\u003e\n\u003cli\u003eExpansion communication status improves system diagnosis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTypical Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIndustry\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eApplication Example\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil and Gas\u003c\/td\u003e\n\u003ctd\u003ePressure, flow, and level transmitter monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Generation\u003c\/td\u003e\n\u003ctd\u003eAnalog equipment condition monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment\u003c\/td\u003e\n\u003ctd\u003ePump and process parameter control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing\u003c\/td\u003e\n\u003ctd\u003eMachine automation signal acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Processing\u003c\/td\u003e\n\u003ctd\u003eProcess variable measurement systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eCertification and Quality Information\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured for GE Fanuc industrial automation platforms.\u003c\/li\u003e\n\u003cli\u003eDesigned for industrial PLC system integration.\u003c\/li\u003e\n\u003cli\u003eQuality inspection supports reliable field deployment.\u003c\/li\u003e\n\u003cli\u003ePackaging inspection ensures safe transportation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003ePackage Contents\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC697ALG230\u003c\/b\u003e\u003c\/span\u003e Base Converter Module ×1\u003c\/li\u003e\n\u003cli\u003eRemovable terminal block ×1\u003c\/li\u003e\n\u003cli\u003eProduct documentation support\u003c\/li\u003e\n\u003cli\u003eProtective industrial packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eShipping and Warranty\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFast delivery options include FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eStandard shipping preparation takes 24-48 hours.\u003c\/li\u003e\n\u003cli\u003eProfessional packaging protects industrial components.\u003c\/li\u003e\n\u003cli\u003eWarranty period: 12 months.\u003c\/li\u003e\n\u003cli\u003eTechnical support assists product application questions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: What PLC system uses the IC697ALG230?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module works with the GE Fanuc Series 90-70 PLC platform.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How many analog inputs does this module provide?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides eight differential analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can the module measure both voltage and current signals?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, each channel supports configurable voltage or current measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Which expander modules work with this model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: It supports IC697ALG440 voltage expanders and IC697ALG441 current expanders.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What field experience helps during installation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Engineers should verify loop wiring before changing software settings.\u003c\/p\u003e\n\u003cp\u003eA common issue involves incorrect polarity on differential inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How do technicians improve measurement stability?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Technicians usually use shielded cables and proper grounding methods.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What should buyers confirm before purchase?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Buyers should confirm PLC rack compatibility, signal type, and channel requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Is expansion important for future upgrades?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, expansion modules provide additional channels for system growth.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSelection Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC697ALG230\u003c\/b\u003e\u003c\/span\u003e for Series 90-70 analog input applications.\u003c\/li\u003e\n\u003cli\u003eConfirm required voltage or current measurement ranges.\u003c\/li\u003e\n\u003cli\u003eCheck available PLC rack resources before installation.\u003c\/li\u003e\n\u003cli\u003eChoose expander modules for larger analog systems.\u003c\/li\u003e\n\u003cli\u003eReview environmental conditions before field deployment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eGE Fanuc IC697ALG230\u003c\/b\u003e\u003c\/span\u003e provides reliable analog conversion for demanding automation systems.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014011969718,"sku":"IC697ALG230","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC697ALG230.jpg?v=1785999694","url":"https:\/\/www.plcsparehub.com\/products\/ic697alg230-emerson-ge-fanuc-plc-analog-input-converter-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}