{"product_id":"ic695psd040-pacsystems-rx3i-power-supply-by-ge-fanuc-40w-unit","title":"IC695PSD040 PACSystems RX3i Power Supply by GE Fanuc - 40W Unit","description":"\u003cdiv\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e power supply module delivers stable, regulated energy distribution across the PACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e backplane ecosystem. Originally engineered by GE Intelligent Platforms and supported within Emerson Automation frameworks, this rack-mount unit converts incoming DC supplies into precise internal logic rails. Designed for dedicated Slot 0 deployment, the \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e guarantees optimal voltage stability for complex automation processors and high-density I\/O configurations. Engineering teams depend on its integrated diagnostic tracking and dependable thermal regulation to prevent unexpected controller shutdowns in critical manufacturing processes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc \/ GE Intelligent Platforms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003ePACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 40W DC Power Supply Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Start Range:\u003c\/strong\u003e 18 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Run Range:\u003c\/strong\u003e 12 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Power:\u003c\/strong\u003e 60 Watts at full load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Output Power:\u003c\/strong\u003e 40 Watts maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Rated Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Output Rails:\u003c\/strong\u003e 5.1 VDC (0 to 6 Amps, max 30W), 3.3 VDC (0 to 9 Amps, max 30W), and auxiliary 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Limit:\u003c\/strong\u003e 4 Amps per 100 milliseconds maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRide-Through Time:\u003c\/strong\u003e 10 ms during brief input power dips\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Assignment:\u003c\/strong\u003e Dedicated Slot 0 on universal \u003cstrong\u003eRX3i\u003c\/strong\u003e backplanes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60 degrees Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85 degrees Celsius\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Integration Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Placement:\u003c\/strong\u003e Mount the \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e strictly into Slot 0 of the universal \u003cstrong\u003eRX3i\u003c\/strong\u003e backplane as required by system architecture rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Terminations:\u003c\/strong\u003e Connect incoming DC lines using industrial-grade wiring sizing from 14 AWG to 18 AWG securely fastened to the front terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Constraints:\u003c\/strong\u003e Note that this unit does not support power supply redundancy or increased capacity pairing; budget your rack current draw accordingly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaisy-Chaining:\u003c\/strong\u003e Up to two \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e units can be connected in a daisy-chain configuration, though this setup does not pool or increase aggregate wattage output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning \u0026amp; Maintenance Ease\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e Monitor system health instantly via the onboard LED array covering Power status, P\/S Fault, Overtemperature, and Overload conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual Control:\u003c\/strong\u003e Utilize the front-mounted physical On\/Off power switch to safely isolate rack power during routine maintenance windows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Reporting:\u003c\/strong\u003e Integrated CPU communication links relay power-loss and fault signals directly to the programming software for rapid troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Alignment:\u003c\/strong\u003e Fully optimized for PACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e central processing units and rack components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Device Support:\u003c\/strong\u003e Auxiliary 24 VDC output supplies clean energy directly to external relay output circuits and field loop devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Standards:\u003c\/strong\u003e Manufactured to meet rigorous electrical safety and environmental endurance specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePacking List \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacking List:\u003c\/strong\u003e One (1) \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e Power Supply Unit, protective industrial casing, and hardware compliance documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Protected by a comprehensive 12-month warranty covering material defects and functional performance from the invoice date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier Partners:\u003c\/strong\u003e Express global delivery serviced through FedEx, UPS, and DHL logistics networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Window:\u003c\/strong\u003e Orders are rigorously tested, securely packaged, and dispatched within 24-48 hours to eliminate project downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly Lines:\u003c\/strong\u003e Supplying clean, uninterrupted logic power to high-speed modular controllers managing robotic welding cells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Treatment Facilities:\u003c\/strong\u003e Powering continuous monitoring racks and remote telemetry units exposed to variable environmental conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Management Systems:\u003c\/strong\u003e Energizing high-density discrete and analog I\/O cards within electrical substation automation enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eWhen designing dense control racks using the \u003cstrong\u003eIC695PSD040\u003c\/strong\u003e, field engineers must calculate total backplane current consumption carefully. Because this unit is restricted to Slot 0 and lacks parallel redundancy modes, exceeding the 40W threshold will trigger overload protections. Our engineering team recommends keeping total module current draws at least 15% below maximum rated thresholds and separating heavy relay loads onto auxiliary power sources to maintain long-term system stability.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if total backplane power demand exceeds 40 Watts on an IC695PSD040?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExceeding the 40W capacity will trip the internal overload protection circuit, activating the overload LED indicator and potentially shutting down rack logic. You must distribute heavy I\/O cards across an additional separate backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan two IC695PSD040 units be paralleled to double the output wattage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, while up to two modules can be daisy-chained for specific wiring layouts, they cannot be paralleled to increase total output power or achieve redundancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the 10 ms ride-through time feature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ride-through time allows the module to maintain stable output voltage rails for up to 10 milliseconds during momentary input voltage sags or brief supply interruptions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the CPU detect internal power supply failures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features hardwired diagnostic indicators linked directly to the system CPU, allowing software environments to flag P\/S faults or thermal overloads instantly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wire gauge should be used for the input power terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField wiring should utilize copper conductors sized between 14 AWG and 18 AWG to ensure secure terminal seating and prevent excessive voltage drop under load.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013992669366,"sku":"IC695PSD040","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695PSD040.jpg?v=1786504940","url":"https:\/\/www.plcsparehub.com\/products\/ic695psd040-pacsystems-rx3i-power-supply-by-ge-fanuc-40w-unit","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}