{"product_id":"ic695psa140-power-supply-module-ge-intelligent-platforms-rx3i","title":"IC695PSA140 Power Supply Module GE Intelligent Platforms RX3i","description":"\u003ch3\u003eEngineering Overview\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: Advanced industrial automation racks handling high-density I\/O modules demand robust power delivery, galvanic isolation, and fault-tolerant redundancy architecture. The \u003cb\u003eGE Fanuc\u003c\/b\u003e \/ \u003cb\u003eGE Intelligent Platforms\u003c\/b\u003e \u003cb\u003eIC695PSA140\u003c\/b\u003e from the premier \u003cb\u003eRX3i PacSystem\u003c\/b\u003e line serves as a multi-purpose universal backplane power supply engineered to support up to 40 Watts of total output. Based on our field engineering experience, deploying redundant power configurations prevents unexpected controller downtime and safeguards continuous process control loops during primary line voltage anomalies.\u003c\/p\u003e\n\u003ch3\u003eModule Architecture and Diagnostic Layout\u003c\/h3\u003e\n\u003cpre style=\"background-color: #f4f4f4; padding: 15px; border: 1px solid #ddd; font-family: monospace;\"\u003e+-----------------------------------------------------------------------+\n| GE\/GEIP IC695PSA140 SYSTEM ARCHITECTURE BLUEPRINT                     |\n+-----------------------------------------------------------------------+\n|  [+] Slot Footprint     : Occupies 2 universal backplane slots        |\n|  [+] Output Rails       : +5.1 VDC, +24 VDC relay, and +3.3 VDC       |\n|  [+] Diagnostic LEDs    : Power, P\/S Fault, Overtemp, and Overload    |\n|  [+] Redundancy Support : Hot-standby load sharing capability         |\n+-----------------------------------------------------------------------+\n\u003c\/pre\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth style=\"text-align: left;\"\u003eParameter Metric\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eOperating Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand \/ Manufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eGE Fanuc\u003c\/b\u003e \/ \u003cb\u003eGE Intelligent Platforms\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eIC695PSA140\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSeries \/ Product Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cb\u003eRX3i PacSystem\u003c\/b\u003e\u003c\/a\u003e \/ \u003cb\u003eMulti-Purpose Power Supply\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100 to 300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power\u003c\/td\u003e\n\u003ctd\u003e40 Watts total capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rail Specifications\u003c\/td\u003e\n\u003ctd\u003e+5.1 VDC (max 30W), +24 VDC relay (max 30W), +3.3 VDC internal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limits\u003c\/td\u003e\n\u003ctd\u003e5.1V limited to 7A; 3.3V limited to 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Backplane Only (Max 4 units per rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide-Through Time\u003c\/td\u003e\n\u003ctd\u003e20 milliseconds during line power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Consumption\u003c\/td\u003e\n\u003ctd\u003e70 Watts maximum at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSupply Chain and Commercial Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCondition: Brand new and original in factory packaging.\u003c\/li\u003e\n\u003cli\u003eFactory Warranty: Comprehensive 12-month coverage.\u003c\/li\u003e\n\u003cli\u003eShipping Carriers: FedEx, UPS, DHL.\u003c\/li\u003e\n\u003cli\u003eFulfillment Window: Fast dispatch within 24 to 48 hours of order clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Equipment and Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-scale GE PACSystems RX3i control racks in heavy manufacturing plants.\u003c\/li\u003e\n\u003cli\u003eContinuous process automation skids requiring dual-redundant power backup.\u003c\/li\u003e\n\u003cli\u003eHigh-density I\/O configurations exceeding standard single-supply power limits.\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure control panels demanding hot-standby load sharing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTriggers internal fault latching to signal the RX3i CPU upon hardware or over-temperature trips.\u003c\/li\u003e\n\u003cli\u003eMonitors thermal operating thresholds via dedicated Overtemp and Overload LED indicators.\u003c\/li\u003e\n\u003cli\u003eProtects internal circuitry against current surges using built-in electronic limits and backup fusible links.\u003c\/li\u003e\n\u003cli\u003eMaintains valid output rails for 20 milliseconds during momentary power sags or dropouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eWhy does the IC695PSA140 require a power cycle after experiencing an overcurrent fault?\u003c\/b\u003e\u003cbr\u003eWhen an internal overcurrent or overtemperature condition latches the power supply to the OFF state, safety protocols mandate a manual power cycle to verify fault clearing before re-energizing the backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHow does load sharing function when multiple power supplies are installed in an RX3i rack?\u003c\/b\u003e\u003cbr\u003eInstalling multiple compatible supplies allows them to share the total electrical load evenly, reducing individual thermal stress and providing seamless failover if one module drops offline.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhat is the primary purpose of the isolated +24 VDC relay output rail?\u003c\/b\u003e\u003cbr\u003eThe +24 VDC relay output provides auxiliary power capable of driving external field loops, interlock relays, or discrete control circuits alongside internal backplane requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhy does this power supply occupy two physical slots on the universal backplane?\u003c\/b\u003e\u003cbr\u003eThe two-slot physical footprint houses upgraded heat dissipation sinks, high-capacity transformers, and dual-tier voltage conversion circuitry necessary to sustain 40 Watts of reliable output.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhat guidelines should engineers follow when planning redundancy layouts for RX3i systems?\u003c\/b\u003e\u003cbr\u003eEnsure total system power draw does not exceed the capacity of a single supply if running true N+1 redundancy, and verify firmware compatibility across all installed IC695 modules.\u003c\/p\u003e\n\u003ch3\u003eSelection Guide and Technical Comparison\u003c\/h3\u003e\n\u003cp\u003eSelecting the correct power supply variant depends on your cabinet voltage availability and total wattage requirements. Compare the \u003cb\u003eGE Fanuc\u003c\/b\u003e \u003cb\u003eIC695PSA140\u003c\/b\u003e with alternative RX3i power modules to optimize your system configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/ic695psa040-ge-fanuc-rx3i-power-supply\"\u003eIC695PSA040\u003c\/a\u003e: Features standard single-slot auxiliary power specifications tailored for smaller standalone RX3i automation racks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013992145078,"sku":"IC695PSA140","price":213.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695PSA140.jpg?v=1785316733","url":"https:\/\/www.plcsparehub.com\/products\/ic695psa140-power-supply-module-ge-intelligent-platforms-rx3i","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}