{"product_id":"ic695psa040-ge-fanuc-emerson-rx3i-pacsystems-40w-power-supply-module","title":"IC695PSA040 GE Fanuc Emerson RX3i PACSystems 40W Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PSA040\u003c\/strong\u003e\u003c\/span\u003e is a 40-Watt multi-purpose base power supply module within the Emerson \/ GE Fanuc \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePACSystems RX3i Series\u003c\/strong\u003e\u003c\/span\u003e. Operating from universal AC or DC line inputs, it converts incoming supply voltage into regulated DC power outputs required by local backplane modules. The unit delivers +5.1 VDC and +3.3 VDC to drive backplane logic circuits, alongside +24 VDC relay power to energize external field outputs. Engineered for high operational availability, it features a rugged front-panel ON\/OFF control switch and diagnostic LEDs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical \u0026amp; Output Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand \u0026amp; Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Intelligent Platforms \/ Emerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \u0026amp; Catalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PSA040\u003c\/strong\u003e\u003c\/span\u003e (\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePACSystems RX3i Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Base Multi-Purpose Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 Watts total continuous output power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Input Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC (120\/240 VAC nominal); 47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Input Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 300 VDC (125 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Input Power Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 Watts at maximum load; 4 A peak inrush for 250 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+5.1 VDC Output Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 to 5.2 VDC regulation; 0 to 6.0 Amperes continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+3.3 VDC Output Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.1 to 3.5 VDC regulation; 0 to 9.0 Amperes continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e+24 VDC Relay Output Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 to 28.8 VDC regulation; 0 to 1.6 Amperes continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Isolation Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous isolation; 1500 VAC withstand test for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Constraints \u0026amp; Mechanical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRX3i Universal Backplane (IC695 chassis series only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Installation Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum four (4) power supply modules per IC695 rack assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParalleling \/ Redundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDoes not support load sharing or fault-tolerant redundancy in same rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Connection Density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccommodates up to 6 Amperes max current per wiring terminal point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic LED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower, P\/S Fault, Over Temperature, and Overload status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Access Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHinged door covers master ON\/OFF switch featuring protective lockout tab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Applications \u0026amp; Hardware Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PSA040\u003c\/strong\u003e\u003c\/span\u003e serves central processing racks in power generation plants, water treatment systems, and continuous manufacturing facilities. Maintenance technicians utilize its four front-panel diagnostic LEDs to isolate power faults quickly. An active P\/S Fault or Over Temperature LED indicates thermal saturation or internal component degradation. An active Overload LED alerts operators that connected I\/O cards exceed the 40 W total output envelope, signaling a need to redistribute modules into expansion chassis.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring system retrofits on older plant racks, field engineers occasionally attempt to install the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PSA040\u003c\/strong\u003e\u003c\/span\u003e alongside another power module in the same universal base to boost total wattage. Because this standard 40W unit lacks load-sharing diodes, placing two in parallel creates reverse-current faults. To expand system capacity without tripping internal protection, engineers must relocate high-draw analog or motion cards into expansion racks powered by their own dedicated supplies.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection Comparison \u0026amp; Technical Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvaluate power requirements within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePACSystems RX3i Series\u003c\/strong\u003e\u003c\/span\u003e platform prior to ordering:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard 40W Unit:\u003c\/strong\u003e The \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695PSA040\u003c\/strong\u003e\u003c\/span\u003e provides 40 Watts of non-redundant base power for standard density CPU and discrete I\/O racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity \/ Redundant Options:\u003c\/strong\u003e For heavy analog racks or critical applications requiring redundant supply backup, high-capacity or load-sharing variants must be specified instead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Tip:\u003c\/strong\u003e Always tally the total backplane current draw (+3.3V, +5.1V, and +24V relay) for all planned cards using machine design software. If the calculated consumption exceeds 40 Watts, migrate additional I\/O to expansion chassis rather than exceeding the load rating of the primary base supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty, Dispatch \u0026amp; Packaging Guarantees\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Condition:\u003c\/strong\u003e 100% Brand New and Original in Factory Sealed Packaging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Covered by a full 12 Months factory warranty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Processing Speed:\u003c\/strong\u003e Ships out within 24 to 48 hours following order confirmation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpress Logistics Carriers:\u003c\/strong\u003e Worldwide express delivery via FedEx, UPS, and DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does flipping the front panel ON\/OFF switch isolate incoming AC\/DC mains line voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the toggle switch disables internal DC outputs only; dangerous line potential remains present at the input wiring terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this unit operate on 125 VDC station battery banks without hardware jumper adjustments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, its universal front-end automatically accepts 100 to 300 VDC or 85 to 264 VAC without manual range configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if connected backplane modules demand more than 6 Amperes on the +5.1 VDC rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Overload LED illuminates, and internal over-current protection shuts down DC outputs to prevent permanent module damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this power supply compatible with older Series 90-30 expansion backplanes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, it mounts exclusively into RX3i universal backplanes (IC695 series) and cannot be installed in legacy IC693 racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How can technicians verify if a thermal shutdown has occurred in an unventilated cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Inspect the front faceplate; an illuminated Over Temperature LED confirms thermal trip, requiring enclosure cooling before resetting the power switch.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013996208310,"sku":"IC695PSA040","price":321.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695PSA040.jpg?v=1785316678","url":"https:\/\/www.plcsparehub.com\/products\/ic695psa040-ge-fanuc-emerson-rx3i-pacsystems-40w-power-supply-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}