{"product_id":"ic695pbm300-profibus-master-module-pacsystems-rx3i","title":"IC695PBM300 Profibus Master Module - PACSystems RX3i","description":"\u003cdiv\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e is an advanced PROFIBUS DP Master communication module engineered for the PACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e series, originally developed by GE Intelligent Platforms (GE IP) and currently supported within Emerson Automation ecosystems. This module bridges high-level controllers and industrial field devices, empowering the \u003cstrong\u003eRX3i\u003c\/strong\u003e CPU to seamlessly orchestrate data exchange across complex networks. Designed to optimize industrial infrastructures, it guarantees reliable, high-speed telemetry for up to 125 DP slaves. Engineering teams rely on its robust diagnostic feature set and deterministic communication capabilities to maintain maximum operational uptime in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc \/ GE Intelligent Platforms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003ePACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PROFIBUS Master Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e One (1) RS-485 \/ RS-232 Port with 9-pin Sub-D connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e PROFIBUS-DP, DP-V1 Read, Write, and Alarm messages, Sync and Freeze modes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum DP Slaves:\u003c\/strong\u003e Up to 125 slave units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Data Capacity:\u003c\/strong\u003e 244 Bytes per slave; 3,584 Bytes total network input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Data Capacity:\u003c\/strong\u003e 244 Bytes per slave; 3,584 Bytes total network output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaud Rates Supported:\u003c\/strong\u003e 9.6K, 19.2K, 93.75K, 187.5K, 500K, 1.5M, 3M, 6M, and 12M Baud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Compatibility:\u003c\/strong\u003e Universal \u003cstrong\u003eRX3i\u003c\/strong\u003e PCI Backplane (Single Slot)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Power Consumption:\u003c\/strong\u003e 440 mA @ 3.3 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e 0 to 60 degrees Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e -40 to 85 degrees Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Designed for standard industrial control panel conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Lifecycle Status:\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Integration Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Assignment:\u003c\/strong\u003e Mount the \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e into any single available PCI slot on a universal \u003cstrong\u003eRX3i\u003c\/strong\u003e backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Prerequisite:\u003c\/strong\u003e Ensure the host \u003cstrong\u003eRX3i\u003c\/strong\u003e CPU operates on firmware version 2.9 or later to guarantee master-slave compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Requirement:\u003c\/strong\u003e Configure the module using Machine Edition Logic Developer PLC software version 5.0 SP2 or newer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Utilize a standard PROFIBUS bus cable terminated securely into the integrated 9-pin Sub-D connector to minimize signal reflections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning \u0026amp; Maintenance Ease\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Updates:\u003c\/strong\u003e Upgrade the \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e firmware indirectly via the host controller using the WinLoader software utility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Monitoring:\u003c\/strong\u003e Rely on onboard LED indicators—including the PROFIBUS OK LED, Network indicator, and MOD status indicators—for instant visual health checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e Access the Slave Status Bit Array Table, Network Diagnostic Counters, DP Master Diagnostic Counters, and specific Slave Diagnostic Addresses to isolate communication faults quickly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Compatibility:\u003c\/strong\u003e Fully compatible with PACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e CPU backplane architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Compatibility:\u003c\/strong\u003e Interoperable with any standard PROFIBUS-DP compliant field slave device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e Built to meet major industrial electrical and safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePacking List \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacking List:\u003c\/strong\u003e One (1) \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e PROFIBUS Master Module, protective packaging casing, and hardware documentation sheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Backed by a comprehensive \u003cstrong\u003e12-month warranty\u003c\/strong\u003e covering structural and operational integrity from the date of purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier Partners:\u003c\/strong\u003e Fast and reliable dispatch via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling Time:\u003c\/strong\u003e Processed and dispatched within \u003cstrong\u003e24-48 hours\u003c\/strong\u003e of order confirmation to minimize operational delays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Manufacturing:\u003c\/strong\u003e Coordinating high-speed data exchanges between programmable logic controllers and distributed remote I\/O drops on assembly lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Managing telemetry signals from intelligent field instruments, drives, and valve islands in chemical or water treatment facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Integrating legacy and modern sensor arrays into a unified, deterministic automation bus architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eEngineering teams frequently encounter network dropouts during high-baud-rate commissioning if termination resistors are omitted at both physical ends of the PROFIBUS line. Based on field experience with the \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e, always verify shield grounding and use active termination blocks when running cable lengths exceeding 100 meters at 1.5 MBaud or higher. Furthermore, mapping input and output data blocks carefully within the 3,584-byte system limit prevents memory overflow errors in complex multi-slave topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat CPU firmware version is required to operate the IC695PBM300?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires an \u003cstrong\u003eRX3i\u003c\/strong\u003e CPU running firmware version 2.9 or later to ensure reliable communication and proper master-slave initialization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC695PBM300 handle DP-V1 communication messages?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module fully supports PROFIBUS DP-V1 read, write, and alarm messages alongside standard cyclic data exchange.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are firmware updates applied to this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirmware updates are deployed indirectly via the host \u003cstrong\u003eRX3i\u003c\/strong\u003e controller using the WinLoader software utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of slave devices supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e supports communication with up to 125 active PROFIBUS-DP slave devices simultaneously.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013994471606,"sku":"IC695PBM300","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695PBM300.jpg?v=1786504868","url":"https:\/\/www.plcsparehub.com\/products\/ic695pbm300-profibus-master-module-pacsystems-rx3i","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}