{"product_id":"ic695nkt002-ge-emerson-rx3i-ethernet-niu-kit-global-plc-spare-hub","title":"IC695NKT002 GE Emerson RX3i Ethernet NIU Kit | Global PLC Spare HUB","description":"\u003cdiv\u003e\n\u003ch3\u003eProduct Introduction\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695NKT002\u003c\/strong\u003e is an engineered PACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e assembly kit manufactured by Emerson Automation, building upon the trusted legacy of GE Intelligent Platforms (GE IP). Designed for industrial networking and system expansion, this packaged kit streamlines procurement by bundling essential hardware into a single solution. The kit includes one \u003cstrong\u003eIC695NIU001\u003c\/strong\u003e Ethernet Network Interface Unit and two \u003cstrong\u003eIC695ETM001\u003c\/strong\u003e Ethernet Interface Modules.\u003c\/p\u003e\n\u003cp\u003eThis assembly serves as an ideal solution for engineers looking to modernize legacy infrastructure without undertaking a complete system rip-and-replace. By bridging modern controller platforms with established Series 90-30 I\/O modules and VersaMax hardware, the \u003cstrong\u003eIC695NKT002\u003c\/strong\u003e facilitates smooth phased migrations.\u003c\/p\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eIn real-world automation revamps, system downtime during a migration poses a major operational risk. Drawing from field deployment experience at large distribution facilities, engineers often utilize the \u003cstrong\u003eIC695NKT002\u003c\/strong\u003e kit to upgrade central processing capabilities while retaining existing field wiring and remote I\/O racks. For instance, when retrofitting an older water treatment plant or a large warehouse material handling network, replacing every single I\/O drop is cost-prohibitive. Deploying the \u003cstrong\u003eIC695NIU001\u003c\/strong\u003e base unit allows the existing Series 90-30 I\/O modules to communicate seamlessly with new controller networks via robust serial and Ethernet data exchange, cutting commissioning time by half and minimizing cabling errors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Intelligent Platforms \/ Emerson Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003ePACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003eIC695NKT002\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Ethernet Network Interface Unit Kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit Contents:\u003c\/strong\u003e One (1) \u003ca href=\"https:\/\/www.ubestplc.com\/products\/ic695niu001-ge-fanuc-rx3i-ethernet-network-interface-unit\"\u003e\u003cstrong\u003eIC695NIU001\u003c\/strong\u003e\u003c\/a\u003e ENIU and Two (2) \u003ca href=\"https:\/\/www.ubestplc.com\/products\/ge-fanuc-ic695etm001-rx3i-ethernet-module\"\u003e\u003cstrong\u003eIC695ETM001\u003c\/strong\u003e\u003c\/a\u003e Ethernet Modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded Flash Memory:\u003c\/strong\u003e 10 MB total (10 MB dedicated to \u003cstrong\u003eIC695NIU001\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal Logic Capacity:\u003c\/strong\u003e 240 KB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e TCP\/IP, GE Fanuc SRTP, EGD, Modbus RTU, SNP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports (IC695NIU001):\u003c\/strong\u003e Two (2) configurable RS-232 \/ RS-485 ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Ports (IC695ETM001):\u003c\/strong\u003e Two (2) RJ45 Ethernet ports, One (1) Station Manager port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Ratings (IC695NIU001):\u003c\/strong\u003e 3.3 VDC at 0.52 Amps nominal; +5.0 VDC at 0.95 Amps nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 degrees Celsius to 60 degrees Celsius (32 degrees Fahrenheit to 140 degrees Fahrenheit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e Resistant to standard industrial vibration and ambient electrical noise\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Compatibility:\u003c\/strong\u003e Any standard \u003cstrong\u003eRX3i\u003c\/strong\u003e Backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloating Point Support:\u003c\/strong\u003e Fully supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Clock:\u003c\/strong\u003e Battery-backed hardware clock integrated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure all rack power is completely disconnected before inserting or removing the \u003cstrong\u003eIC695NKT002\u003c\/strong\u003e components.\u003c\/li\u003e\n\u003cli\u003eMount the \u003cstrong\u003eIC695NIU001\u003c\/strong\u003e and \u003cstrong\u003eIC695ETM001\u003c\/strong\u003e modules securely onto any valid slot within the \u003cstrong\u003eRX3i\u003c\/strong\u003e backplane.\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding of the backplane to prevent common-mode electrical transients from affecting high-speed Ethernet communication.\u003c\/li\u003e\n\u003cli\u003eConnect the power supply terminals, observing correct polarity and voltage thresholds for the \u003cstrong\u003eIC695NIU001\u003c\/strong\u003e module.\u003c\/li\u003e\n\u003cli\u003eConfigure IP addresses and communication parameters using programming software before initiating network data exchanges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning, Maintenance, \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in LED indicators on the \u003cstrong\u003eIC695NIU001\u003c\/strong\u003e (such as NIU OK, Scanning I\/O, Outputs Enabled, and Syst Fault) provide immediate visual feedback on system health.\u003c\/li\u003e\n\u003cli\u003eStatus LEDs on the \u003cstrong\u003eIC695ETM001\u003c\/strong\u003e (including Ethernet OK, LAN OK, and Log Empty) assist technicians in rapidly isolating network anomalies.\u003c\/li\u003e\n\u003cli\u003eRoutine maintenance involves checking the battery-backed Real Time Clock status and inspecting network cable terminations for physical wear.\u003c\/li\u003e\n\u003cli\u003eFirmware updates can be applied via serial or Ethernet links using authorized configuration tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully compatible with standard \u003cstrong\u003eRX3i\u003c\/strong\u003e backplanes and power supply modules.\u003c\/li\u003e\n\u003cli\u003eInterfaces directly with legacy Series 90-30 I\/O racks and VersaMax expansion setups.\u003c\/li\u003e\n\u003cli\u003eSupports data exchange via Ethernet Global Data (EGD) across multi-node automation architectures.\u003c\/li\u003e\n\u003cli\u003eCompatible with optional accessories including the Real Time Clock Battery (\u003cstrong\u003eIC690ACC001\u003c\/strong\u003e), Mini Converter Kit (\u003cstrong\u003eIC690ACC901\u003c\/strong\u003e), and RS-485 Port Isolator (\u003cstrong\u003eIC690ACC903\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance \u0026amp; Quality Assurance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufactured in accordance with strict global industrial safety standards.\u003c\/li\u003e\n\u003cli\u003eMeets rigorous electromagnetic compatibility guidelines for high-interference factory floors.\u003c\/li\u003e\n\u003cli\u003eBacked by a comprehensive \u003cstrong\u003e12-month warranty\u003c\/strong\u003e covering hardware integrity and functional performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecurely packaged in anti-static, shock-absorbing industrial containers to prevent transit damage.\u003c\/li\u003e\n\u003cli\u003ePackage includes: One (1) \u003cstrong\u003eIC695NIU001\u003c\/strong\u003e unit, Two (2) \u003cstrong\u003eIC695ETM001\u003c\/strong\u003e modules, and protective documentation.\u003c\/li\u003e\n\u003cli\u003eGlobal shipping expedited via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eRapid fulfillment with orders processed and dispatched within \u003cstrong\u003e24-48 hours\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Sectors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDiscrete manufacturing assembly lines requiring legacy I\/O retention.\u003c\/li\u003e\n\u003cli\u003eContinuous process control in chemical and petrochemical facilities.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment monitoring networks.\u003c\/li\u003e\n\u003cli\u003eLarge-scale warehouse material handling and automated logistics distribution centers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose the \u003cstrong\u003eIC695NKT002\u003c\/strong\u003e kit when deploying a complete dual-Ethernet interface and network unit assembly for optimal cost savings.\u003c\/li\u003e\n\u003cli\u003eVerify your backplane slot availability, as the kit requires space for one main NIU and two auxiliary Ethernet interface cards.\u003c\/li\u003e\n\u003cli\u003eAssess your network redundancy requirements to ensure dual \u003cstrong\u003eIC695ETM001\u003c\/strong\u003e module configuration aligns with your system architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the components inside the IC695NKT002 kit be purchased separately?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003eIC695NIU001\u003c\/strong\u003e and \u003cstrong\u003eIC695ETM001\u003c\/strong\u003e modules are available as individual catalog items if required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the IC695NKT002 assist with system migration?\u003c\/strong\u003e\u003cbr\u003eA: It allows plant engineers to keep existing Series 90-30 I\/O wiring intact while upgrading the controller network backbone to modern PACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the primary communication protocols supported by the serial ports?\u003c\/strong\u003e\u003cbr\u003eA: The serial ports support Modbus RTU Slave, SNP, Serial I\/O, and Modbus RTU Master protocols configured via application blocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What shipping carriers are utilized for international orders?\u003c\/strong\u003e\u003cbr\u003eA: All orders are dispatched globally via trusted carriers including \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e with 24-48 hour processing times.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What warranty coverage is provided with this hardware?\u003c\/strong\u003e\u003cbr\u003eA: The product is protected by a full \u003cstrong\u003e12-month warranty\u003c\/strong\u003e ensuring operational reliability.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014010233014,"sku":"IC695NKT002","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695NKT002-1.jpg?v=1790141645","url":"https:\/\/www.plcsparehub.com\/products\/ic695nkt002-ge-emerson-rx3i-ethernet-niu-kit-global-plc-spare-hub","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}