{"product_id":"ic695lre001-ge-fanuc-pacsystems-rx3i-serial-bus-transmitter","title":"IC695LRE001 GE Fanuc PACSystems RX3i Serial Bus Transmitter","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #004085;\"\u003eGE Intelligent Platforms \/ GE Fanuc\u003c\/strong\u003e \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e is a high-speed serial bus transmitter module. It bridges the main \u003cstrong style=\"color: #004085;\"\u003ePACSystems RX3i\u003c\/strong\u003e universal backplane with remote expansion racks. The unit translates backplane logic signals into differential serial signals. It enables seamless data flow across distributed automation chassis over long distances.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong style=\"color: #004085;\"\u003eGE Intelligent Platforms \/ GE Fanuc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cstrong style=\"color: #004085;\"\u003ePACSystems RX3i\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Serial Bus Transmitter Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Requirement:\u003c\/strong\u003e 1 Dedicated Expansion Slot (Rightmost Universal Backplane Connector)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e 132 mA @ +5 VDC (0 mA @ +3.3 VDC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e RS-232 \/ Non-isolated Differential\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEffective Data Transmission Rate:\u003c\/strong\u003e 500 kbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Local Expansion Cable Length:\u003c\/strong\u003e 50 feet (15 meters)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Remote Expansion Cable Length:\u003c\/strong\u003e 700 feet (213 meters)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Diagnostics:\u003c\/strong\u003e 2 Visual Status LEDs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility and Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module plugs into the rightmost expansion slot on the \u003cstrong style=\"color: #004085;\"\u003eRX3i\u003c\/strong\u003e universal backplane. It links serial expansion backplanes directly to the main system CPU. The hardware supports legacy \u003cstrong style=\"color: #004085;\"\u003eGE Series 90-30\u003c\/strong\u003e serial expansion racks. System logic handles I\/O scanning transparently without custom protocol code.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Mounting Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAlways disconnect main power before mounting the module into the chassis slot. Insert the \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e into the designated expansion connector on the universal rack. Tighten panel retention screws securely to establish proper electrical grounding. Attach the shielded expansion cable to the front-facing multi-pin port.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities and LED Status\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTwo diagnostic LEDs provide real-time operational feedback for system technicians. The Expansion OK LED turns solid green when 5V backplane power is active. The Expansion Active LED illuminates during active data exchange across the bus. If communication breaks down, the Active LED turns off immediately to indicate fault conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLarge-scale water treatment plants requiring distributed I\/O racks across separate control rooms.\u003c\/li\u003e\n\u003cli\u003eAutomotive stamping lines linking remote valve manifolds to the main \u003cstrong style=\"color: #004085;\"\u003eRX3i\u003c\/strong\u003e processor.\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems spanning up to 700 feet across warehouse facilities.\u003c\/li\u003e\n\u003cli\u003ePower generation skids requiring centralized monitoring of distant field instrumentation chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring a plant upgrade, a customer experienced periodic communication loss on a 400-foot expansion drop. The customer originally suspected a faulty \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e module. Field diagnostics revealed missing cable shielding ground connections near high-voltage motor drives. Properly grounding the shield drained industrial noise and restored stable 500 kbps communication. Always route long expansion cables away from high-voltage AC wiring to prevent EMI interference.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection and Purchasing Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eChoose the \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e when expanding local or remote I\/O chassis via serial connections. Calculate total cable distance before selection to stay within the 700-foot maximum limit. Verify that your universal backplane contains an open right-side expansion connector slot.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents and 12-Month Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEach shipment contains one \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e serial bus transmitter module. All items undergo full functional testing prior to dispatch. Every module includes a comprehensive 12-month replacement warranty against technical defects.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping and Delivery Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOrders process quickly and ship within 24 to 48 hours following payment verification. Global express shipping options include FedEx, UPS, and DHL. Tracking details send automatically once the carrier receives your shipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where do I install the \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e transmitter module in the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Install it specifically into the custom expansion connector slot on the right side of the universal backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What cable distance does the \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e support for remote chassis links?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It supports up to 50 feet for local expansion cables and 700 feet for remote expansion cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What causes the Expansion Active LED to turn off during machine operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The LED turns off when data communication fails between the main rack and remote expansion chassis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the \u003cstrong style=\"color: #004085;\"\u003eIC695LRE001\u003c\/strong\u003e module require external 24 VDC auxiliary power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, it draws 132 mA directly from the 5 VDC backplane supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do field technicians prevent signal dropouts on long remote cable runs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Ensure proper cable shield termination and maintain separation from high-voltage power lines.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013994438838,"sku":"IC695LRE001","price":226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695LRE001.jpg?v=1786504888","url":"https:\/\/www.plcsparehub.com\/products\/ic695lre001-ge-fanuc-pacsystems-rx3i-serial-bus-transmitter","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}