{"product_id":"ic695gcg001-ge-fanuc-rx3i-pacsystems-genius-communication-interface","title":"IC695GCG001 GE Fanuc RX3i PACSystems Genius Communication Interface","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/b\u003e \u003cb style=\"color: #0056b3;\"\u003eIC695GCG001\u003c\/b\u003e acts as a high-efficiency \u003cb style=\"color: #0056b3;\"\u003eGenius communication gateway\u003c\/b\u003e for demanding industrial control environments.\u003c\/p\u003e\n\u003cp\u003eThis intelligent unit bridges legacy network infrastructure into modern \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cb style=\"color: #0056b3;\"\u003ePACSystems RX3i\u003c\/b\u003e\u003c\/a\u003e hardware architectures seamlessly.\u003c\/p\u003e\n\u003cp\u003eIt provides a reliable migration path, allowing plants to retain legacy field blocks without full system decommissioning.\u003c\/p\u003e\n\u003cp\u003eControl engineers deploy this interface to map serial field bus signals directly into high-speed Ethernet control layers.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCore Identification:\u003c\/b\u003e Originally designed by \u003cb style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/b\u003e, now manufactured by \u003cb style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/b\u003e. The specific model number is \u003cb style=\"color: #0056b3;\"\u003eIC695GCG001\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModule Classification:\u003c\/b\u003e Functions as a dedicated network conversion bridge belonging to the \u003cb style=\"color: #0056b3;\"\u003ePACSystems RX3i\u003c\/b\u003e series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePhysical Interfaces:\u003c\/b\u003e Equipped with 2 RJ45 Ethernet ports and 2 specialized serial Genius network connection points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDevice Capacity:\u003c\/b\u003e Scans, controls, and manages up to 31 distinct Genius blocks or remote field stations simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eData Payload Matrix:\u003c\/b\u003e Allocates a robust data allowance of 1024 bytes of input data and 1024 bytes of output data per gateway unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBus Transmission Speeds:\u003c\/b\u003e Supports both 153.6 Kbps Standard and 153.6 Kbps Extended serial network data transmission speeds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower Requirements:\u003c\/b\u003e Demands an external 24 VDC power supply connection, drawing a maximum current of 0.19 Amperes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUpdate Production Rates:\u003c\/b\u003e Features software-configurable data cyclic intervals of 2ms, 4ms, 8ms, 16ms, 32ms, 128ms, 256ms, or 512ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNetwork Topology Support:\u003c\/b\u003e Integrates smoothly into both linear bus and star network physical structural layouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThermal Operating Limits:\u003c\/b\u003e Withstands operational ambient temperatures ranging precisely from 0 degrees C up to 60 degrees C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eFirst, mount the gateway module securely onto a standard industrial enclosure panel or via an expansion slot kit.\u003c\/p\u003e\n\u003cp\u003eConnect the external 24 VDC power supply cables to the marked terminal block following correct polarity guidelines.\u003c\/p\u003e\n\u003cp\u003eTerminate your existing serial bus drops into the designated Serial 1, Serial 2, and Shield network ports.\u003c\/p\u003e\n\u003cp\u003eInsert the PROFINET network Ethernet cables directly into the built-in RJ45 communication interface communication ports.\u003c\/p\u003e\n\u003cp\u003eVerify all grounding parameters match plant electrical safety codes before turning on the external power source.\u003c\/p\u003e\n\u003cp\u003eEnsure the front panel status indicators show normal operation before loading your automated hardware configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eDebugging and Maintenance Convenience\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe onboard SD card slot facilitates quick firmware updates and allows rapid backing up of vital network configurations.\u003c\/p\u003e\n\u003cp\u003eClearly labeled front-panel markings for Shield In, Shield Out, and Serial lines simplify manual field tracing tasks.\u003c\/p\u003e\n\u003cp\u003eThe module supports structural hot-swapping routines, allowing rapid maintenance transitions when external power is disconnected.\u003c\/p\u003e\n\u003cp\u003eTechnicians easily reference internal diagnostic statistics over standard web browsers or network monitoring management software suites.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThis network bridge links natively with high-performance controllers including RX3i CPE330 and RX3i CPE302 units.\u003c\/p\u003e\n\u003cp\u003eThe internal bridging firmware interfaces smoothly with RX3i CPE305, CPE310, CPU315, CPU320, and CRU320 processing architectures.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet ports support full protocol integration with any standard industrial GE PROFINET input-output controller card.\u003c\/p\u003e\n\u003cp\u003eThe software stack provides built-in alignment for standard network layers including UDP, IP, ARP, and ICMP messaging.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSupported Protocol Suite\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRTC – Real Time Cyclic Protocol (Class 1 and Class 2 Unsynchronized)\u003c\/li\u003e\n\u003cli\u003eRTA – Real Time Acyclic Protocol\u003c\/li\u003e\n\u003cli\u003eDCP – Discovery and Configuration Protocol\u003c\/li\u003e\n\u003cli\u003eCL-RPC – Connectionless Remote Procedure Call\u003c\/li\u003e\n\u003cli\u003eLLDP – Link Layer Discovery Protocol\u003c\/li\u003e\n\u003cli\u003eMRP – Media Redundancy Protocol for Ethernet ring architectures\u003c\/li\u003e\n\u003cli\u003eSNMP – Simple Network Management Protocol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003ePacking List and Warranty Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe factory box delivers 1 genuine \u003cb style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/b\u003e \u003cb style=\"color: #0056b3;\"\u003eIC695GCG001\u003c\/b\u003e communication gateway interface block.\u003c\/p\u003e\n\u003cp\u003eThe shipping container includes industrial anti-static packaging safeguards along with the basic startup terminal wiring manual.\u003c\/p\u003e\n\u003cp\u003eThis communication device includes a complete 12-month product warranty clause against all functional manufacturing failures.\u003c\/p\u003e\n\u003cp\u003eThe active warranty coverage tracking automatically activates upon the physical delivery date to your plant destination.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eShipping Logistics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eOur fulfillment infrastructure guarantees fast order dispatch processing within 24 to 48 hours of payment confirmation.\u003c\/p\u003e\n\u003cp\u003eWe execute international express delivery utilizing the world's most reliable premium logistics networks including FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003cp\u003eYour purchasing department receives instant shipping tracking notifications via email immediately upon product warehouse departure.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTypical Application Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eAutomobile manufacturing plants implement this gateway to connect older assembly line drops into centralized Ethernet networks.\u003c\/p\u003e\n\u003cp\u003ePulp and paper mills deploy the module to migrate extensive legacy motor control blocks to modern controllers.\u003c\/p\u003e\n\u003cp\u003eWater treatment infrastructure facilities utilize the interface to bridge distributed remote pump stations into a PROFINET ring.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe gateway performs continuous active scanning of connected serial nodes to instantly isolate down stations.\u003c\/p\u003e\n\u003cp\u003eBuilt-in Media Redundancy Protocol controls identify ring network breaks and redirect data paths within milliseconds.\u003c\/p\u003e\n\u003cp\u003eIntegrated priority tagging and VLAN support allow engineers to diagnose and filter critical control traffic from background data.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/b\u003e \u003cb style=\"color: #0056b3;\"\u003eIC695GCG001\u003c\/b\u003e provides plant managers an incredible financial advantage during complex system upgrades.\u003c\/p\u003e\n\u003cp\u003eInstead of rewiring dozens of physical field blocks, this single module bridges old and new architectures instantly.\u003c\/p\u003e\n\u003cp\u003eThe dual RJ45 ports give you built-in network flexibility, easily supporting linear, star, or redundant ring setups.\u003c\/p\u003e\n\u003cp\u003eIt is an essential component for heavy infrastructure plants looking to transition to Ethernet without massive downtime budgets.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSelection Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eConfirm your total combined field device requirements do not exceed the 31 maximum station limit per gateway.\u003c\/p\u003e\n\u003cp\u003eCalculate your network bandwidth needs to ensure the 1024-byte input and output limits accommodate your data layout.\u003c\/p\u003e\n\u003cp\u003eVerify that your main central processor model is explicitly listed in our controller compatibility index before ordering.\u003c\/p\u003e\n\u003cp\u003eEnsure you have a separate external 24 VDC power distribution channel ready to supply the necessary 0.2 Amps.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e Can I copy or save my existing network configuration data onto the integrated SD card interface?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e Yes, the SD card slot supports full backing up of Ethernet configuration profiles and simplifies firmware loading updates.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e Does this gateway module allow hot-swapping while the external power supply line remains live?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e No, you must completely disconnect the external 24 VDC power supply before executing a hot-swap hardware replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e What is the maximum data size this module can exchange with a PROFINET controller?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e The hardware handles a maximum data capacity of 1024 bytes of input and 1024 bytes of output data.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e How does the Media Redundancy Protocol function help my plant maintain continuous operational control?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e MRP allows the Ethernet ports to form a redundant ring topology that keeps communicating if a cable breaks.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQuestion:\u003c\/b\u003e What specific baud rates are supported across the serial field network interfaces?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAnswer:\u003c\/b\u003e The module supports standard industrial serial communications running at either 153.6 Kbps Standard or Extended speeds.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014009184438,"sku":"IC695GCG001","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695GCG001.jpg?v=1779091110","url":"https:\/\/www.plcsparehub.com\/products\/ic695gcg001-ge-fanuc-rx3i-pacsystems-genius-communication-interface","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}