{"product_id":"ic695cpe330-emerson-ge-fanuc-pacsystem-rx3i-cpu-controller-module","title":"IC695CPE330 Emerson GE Fanuc PACSystem RX3i CPU Controller Module","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC695CPE330\u003c\/strong\u003e is a high-performance Programmable Automation Controller (PAC) CPU module designed by \u003cstrong style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/strong\u003e (formerly \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/strong\u003e) for the \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003ePACSystem RX3i\u003c\/strong\u003e\u003c\/a\u003e platform. Built upon a 1.6 GHz dual-core processor with a dedicated communications engine, this controller executes complex automation algorithms across high-density industrial applications requiring low-latency synchronization and multi-protocol networking.\u003c\/p\u003e\n\u003cp\u003eFeaturing 64 MB of high-speed RAM and 64 MB of non-volatile user flash storage, the \u003cstrong style=\"color: #0056b3;\"\u003eIC695CPE330\u003c\/strong\u003e manages up to 32K discrete and analog I\/O points across 8 local racks. It comes equipped with three gigabit RJ-45 Ethernet ports (one independent LAN 1 port and a dual-port embedded switch on LAN 2) alongside a USB 2.0 master port for thumb-drive program deployment and maintenance without a programming PC.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSystem Architecture \u0026amp; Feature Set\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDual-Core Processing Architecture\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary 1.6 GHz processor core dedicated exclusively to deterministic logic execution and high-speed scan times.\u003c\/li\u003e\n\u003cli\u003eSecondary dedicated communications co-processor handling protocol stacks, OPC UA server sessions, and backplane bus traffic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGigabit Ethernet \u0026amp; Multi-LAN Networking\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eLAN 1 (Single Port):\u003c\/b\u003e Dedicated RJ-45 10\/100\/1000M port for high-priority controller-to-controller or SCADA links.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLAN 2 (Dual Port Switch):\u003c\/b\u003e Integrated unmanaged switch ports providing ring or daisy-chain topology options for field devices.\u003c\/li\u003e\n\u003cli\u003eHandles up to 48 concurrent SRTP Server connections and 16 Modbus TCP Server sessions (supporting 32 clients per connection).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHigh-Availability Redundancy Support\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eEnables bumpless hot-standby CPU failover architectures via PROFINET controllers, Ethernet Global Data (EGD), and Genius I\/O networks.\u003c\/li\u003e\n\u003cli\u003eSupports external energy backup packs (\u003cstrong style=\"color: #0056b3;\"\u003eIC695ACC402\u003c\/strong\u003e \/ IC695ACC412) to preserve volatile memory contents during main power disruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMulti-Language Execution \u0026amp; Protocol Versatility\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eNative support for IEC 61131-3 languages (Ladder Diagram, Structured Text, Function Block Diagram) and embedded C programming.\u003c\/li\u003e\n\u003cli\u003eDirect protocol translation for PROFINET, OPC UA, Modbus TCP\/RTU, PROFIBUS-DP, DeviceNet, and Reflective Memory (CMX).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003eIC695CPE330\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer \u0026amp; Brand\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/strong\u003e \/ \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003ePACSystem RX3i\u003c\/strong\u003e Control Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCPU Architecture\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.6 GHz Dual-Core Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eUser Program Memory\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e64 MB RAM \/ 64 MB NVRAM Flash Storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Addressing Capacity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e32,768 (32K) Discrete \/ Analog Input and Output Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRack \u0026amp; Slot Footprint\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Slot Module Width (Installs in Main Universal Rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLocal Rack Expansion\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports Up to 8 Local RX3i Expansion Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProgram Block Capacity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 512 Blocks (Up to 128 KB per Individual Block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEthernet Communications\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x RJ-45 Gigabit Ports (10\/100\/1000 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAuxiliary Maintenance Port\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x USB 2.0 Master Type-A Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBackplane Power Draw\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.625 Amps @ +24 VDC (0.0 A @ +5V\/+3.3V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSupported Energy Packs\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIC695ACC402 \/ IC695ACC412 Capacitor Assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperating Temperature Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFront Panel Diagnostics\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6 Status LEDs, Pushbuttons, 3-Position Run Mode Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities \u0026amp; Operational Status Monitoring\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e6-LED Diagnostic Panel:\u003c\/b\u003e Real-time visual tracking of CPU status (OK, RUN, DIAG), Ethernet activity (LAN 1\/2 LINK\/ACT), and battery\/capacitor charge states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHardware Run Mode Switch:\u003c\/b\u003e Physical 3-position toggle switch (RUN W\/OUTPUTS, RUN W\/O OUTPUTS, STOP) for maintenance override protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOPC UA Embedded Diagnostics:\u003c\/b\u003e Provides direct telemetry, CPU thermal limits, memory utilization, and communication error rates to higher-tier MES\/DCS software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUSB Firmware \u0026amp; Logic Upload:\u003c\/b\u003e Enables complete logic backup, restoration, and system event logging via encrypted USB flash drives without software license keys.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTarget Application Scenarios \u0026amp; Systems\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHigh-Speed Packaging Lines:\u003c\/b\u003e Coordinates motion, servo drives, and vision inspection systems using low-jitter PROFINET IRT communication loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower Generation \u0026amp; Turbine Control:\u003c\/b\u003e Executes redundant hot-standby logic failovers across dual-CPU configurations on utility gas and steam turbines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOil \u0026amp; Gas Compressor Racks:\u003c\/b\u003e Manages distributed I\/O blocks over long distances while streaming process variables directly into plant SCADA via OPC UA over Ethernet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Rack Configuration Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSlot Position Mandate:\u003c\/b\u003e Must be installed strictly in the main CPU rack (Slot 0\/1 area) of an RX3i Universal Backplane (IC695CHS012 or CHS016).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEnergy Pack Wiring:\u003c\/b\u003e Connect the optional IC695ACC402 capacitor pack using the IC695CBL002 cable to guarantee non-volatile RAM retention upon complete power loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEthernet Separation:\u003c\/b\u003e Isolate high-volume SCADA traffic on LAN 1 while using LAN 2 ports for local I\/O drop loops to prevent network congestion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003ePackaging, Logistics \u0026amp; Warranty Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch Lead Time:\u003c\/b\u003e In-stock units ready for immediate warehouse dispatch within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExpress International Logistics:\u003c\/b\u003e Priority global shipping provided via DHL Express, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFactory Packaging:\u003c\/b\u003e Supplied 100% Brand New and Original in sealed anti-static factory packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e12-Month Coverage:\u003c\/b\u003e Backed by a comprehensive 12-month quality replacement warranty against operational defect.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eEngineering Procurement Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eVerify Rack Slot Space:\u003c\/b\u003e Ensure the target backplane has two adjacent open slots, as the module dimensions occupy double slot width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCalculate 24VDC Power Requirements:\u003c\/b\u003e Confirm the main 24VDC system power supply capacity covers the 0.625A current draw of the CPU card along with attached option modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSelect Correct Capacitor Pack:\u003c\/b\u003e Match the CPU with an energy pack if your application requires retaining real-time clock and un-cleared table data during power outages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: What occurs if I insert a standard USB drive into the front master port while the controller is running?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The CPU detects the storage device without interrupting logic execution, allowing technicians to upload diagnostic logs or trigger pre-configured script downloads.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How does the dual-core architecture prevent high Ethernet network traffic from affecting logic scan times?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Network handling runs on a dedicated secondary core, isolating Ethernet packet processing from the main logic execution engine.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can this controller be installed in an RX3i expansion or remote I\/O rack?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the processor must be situated in the main CPU rack; remote expansion racks require dedicated expansion receiver modules instead.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What is the main operational difference between LAN 1 and LAN 2 on this CPU card?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: LAN 1 provides a single routed IP address, whereas LAN 2 features an embedded dual-port switch sharing one IP address across two physical ports.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Is an external backup battery mandatory to retain user programs during power loss?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, compiled user programs are saved to 64 MB NVRAM flash storage; the energy pack is only required to preserve unbacked volatile variables and internal clock time.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring an upgrade at a regional water treatment plant, operators were plagued by intermittent communications drops on their legacy rack CPU during peak polling cycles. The single-core processor was struggling to manage SCADA requests while simultaneously executing complex PID loops for chemical dosing pumps.\u003c\/p\u003e\n\u003cp\u003eOur engineering team recommended upgrading to the \u003cstrong style=\"color: #0056b3;\"\u003eIC695CPE330\u003c\/strong\u003e controller. By segregating the plant SCADA network onto LAN 1 and using LAN 2 for localized PROFINET I\/O drops, the plant leveraged the CPU's dual-core design to eliminate communication lag entirely. Logic scan times dropped by over 60%, providing the client with a rock-solid, high-availability control architecture without requiring complete field I\/O rewiring.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013994307766,"sku":"IC695CPE330","price":254.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695CPE330-3.jpg?v=1789013461","url":"https:\/\/www.plcsparehub.com\/products\/ic695cpe330-emerson-ge-fanuc-pacsystem-rx3i-cpu-controller-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}