{"product_id":"ic695cmm004-ge-fanuc-pacsystems-rx3i-serial-module","title":"IC695CMM004 GE Fanuc PACSystems RX3i Serial Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB Review: Global PLC Spare HUB delivers high-performance industrial networking hardware designed for legacy and modern control integration. The \u003cb style=\"color: #0056b3;\"\u003eIC695CMM004\u003c\/b\u003e belongs to the \u003cb style=\"color: #0056b3;\"\u003ePACSystems RX3i\u003c\/b\u003e series, originally engineered by \u003cb style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/b\u003e and currently supported under \u003cb style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/b\u003e. Systems integration engineers deploy this 4-port serial communication module to bridge disparate field instruments, power meters, and variable frequency drives into centralized rack controllers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters \u0026amp; Architecture\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb style=\"color: #0056b3;\"\u003eGE Fanuc \/ Emerson\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb style=\"color: #0056b3;\"\u003eIC695CMM004\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cb style=\"color: #0056b3;\"\u003ePACSystems RX3i\u003c\/b\u003e\u003c\/a\u003e 4-Port Serial Communications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour independent RJ-45 ports supporting RS-232, RS-422, and RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMODBUS Master\/Slave, CCM Slave, DNP3 Master\/Slave, and Serial I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate Spectrum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable transmission speeds from 1200 baud up to 115.2 kilobaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Power Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 Amps at 3.3VDC and 0.15 Amps at 5VDC maximum current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250Vac continuous \/ 1500Vac (1 min) port-to-backplane; 500Vdc continuous port-to-port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degrees Celsius industrial thermal operating threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL\/CUL 508, and ATEX hazardous location compliance markings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Blueprint\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize the CPU rack completely before inserting or extracting the module in hazardous locations.\u003c\/li\u003e\n\u003cli\u003eSlot the unit into any available PCI backplane slot, keeping within the limit of six modules per CPU rack.\u003c\/li\u003e\n\u003cli\u003eConnect standard RJ-45 cables for RS-232 point-to-point links or construct custom pinout wiring for Modbus multi-drop networks.\u003c\/li\u003e\n\u003cli\u003eEnsure shield drains are terminated properly to ground studs to maintain isolation integrity across long cable runs.\u003c\/li\u003e\n\u003cli\u003eApply firmware upgrade kit version 1.34 via software configuration tools if legacy protocol enhancements are required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning and Maintenance Convenience\u003c\/h3\u003e\n\u003cp\u003eOnboard diagnostic LEDs provide immediate local troubleshooting visibility, where blink patterns on the Module OK indicator denote specific system errors such as watchdog timeouts or RAM faults. Handshaking support (RTS\/CTS, RFR\/CTS) simplifies asynchronous modem integration, while removable terminal configurations minimize downtime during scheduled cabinet maintenance.\u003c\/p\u003e\n\u003ch3\u003eCompatibility Framework\u003c\/h3\u003e\n\u003cp\u003eThe unit integrates smoothly into RX3i PACSystems racks alongside standard CPU models. It permits up to six identical serial modules per backplane, enabling a total capacity of 24 active serial communication channels managed by a single controller.\u003c\/p\u003e\n\u003ch3\u003eCertification Information\u003c\/h3\u003e\n\u003cp\u003eCertified for demanding industrial environments, the assembly complies with CE requirements, UL\/CUL 508 safety standards, and ATEX directives, ensuring safe operation when installed with proper enclosure ratings.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents and Warranty\u003c\/h3\u003e\n\u003cp\u003eEach box contains one factory-inspected \u003cb style=\"color: #0056b3;\"\u003eIC695CMM004\u003c\/b\u003e serial module. Global PLC Spare HUB guarantees your operational uptime with a comprehensive 12-month replacement warranty.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Delivery\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB processes and dispatches orders within 24 to 48 hours. Expedited global shipping is managed securely via trusted carriers including FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003ch3\u003eTypical Application Scenarios and Diagnostic Capability\u003c\/h3\u003e\n\u003cp\u003eAutomation professionals deploy the \u003cb style=\"color: #0056b3;\"\u003eIC695CMM004\u003c\/b\u003e across electrical power sub-stations, water treatment telemetry networks, and manufacturing lines utilizing legacy serial devices. Built-in diagnostics report communication dropouts and watchdog status flags directly to the CPU, minimizing troubleshooting hours during network anomalies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy do my Modbus RTU devices fail to respond when using standard RJ-45 patch cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard patch cables do not match the custom pin assignment requirements needed for RS-485 Modbus implementation on these specific ports; custom wiring assemblies must be fabricated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do specific flash counts on the Module OK LED indicate during startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA single blink indicates a watchdog timer expiration, two blinks point to a RAM memory error, six blinks signify invalid CPU configuration, and seven blinks denote a CPU heartbeat failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix RS-232 and RS-485 communication protocols across different ports simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each of the four independent RJ-45 ports can be configured individually for distinct protocols like DNP3 or Modbus operating at varying baud rates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many serial communication modules can a single RX3i CPU backplane support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA maximum of six modules can be installed on a single CPU rack, yielding up to 24 concurrently active serial communication lines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions are necessary when hot-swapping this communication module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must turn off backplane power or verify the location is non-hazardous before connecting or disconnecting field wiring to prevent electrical arcing.\u003c\/p\u003e\n\u003ch3\u003eBuying Guide\u003c\/h3\u003e\n\u003cp\u003eWhen expanding serial communication capacity in GE Fanuc or Emerson RX3i architectures, verify your slot availability, protocol requirements, and cabling topology. Procuring exact factory part numbers like the \u003cb style=\"color: #0056b3;\"\u003eIC695CMM004\u003c\/b\u003e ensures full software compatibility in PAC Machine Edition and protects your control network against integration delays.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014007644342,"sku":"IC695CMM004","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695CMM004.jpg?v=1784621004","url":"https:\/\/www.plcsparehub.com\/products\/ic695cmm004-ge-fanuc-pacsystems-rx3i-serial-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}