{"product_id":"ic695cep001-ge-fanuc-rx3i-profinet-carrier-module","title":"IC695CEP001 GE Fanuc RX3i PROFINET Carrier Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #005a9c;\"\u003e\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #005a9c;\"\u003e\u003cstrong\u003eIC695CEP001\u003c\/strong\u003e\u003c\/span\u003e coordinates high-speed remote I\/O data across decentralized industrial networks. This compact \u003cspan style=\"color: #005a9c;\"\u003e\u003cstrong\u003eRX3i PacSystem\u003c\/strong\u003e\u003c\/span\u003e PROFINET CEP carrier connects field modules directly to a central supervisor controller. It establishes a rugged copper Ethernet communication infrastructure for distributed machinery. Automation engineers deploy this interface to achieve deterministic data synchronization. The slim hardware frame saves valuable footprint space inside packed distribution enclosures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: GE Fanuc \/ GE Intelligent Platforms\u003c\/li\u003e\n\u003cli\u003eModel: \u003cspan style=\"color: #005a9c;\"\u003e\u003cstrong\u003eIC695CEP001\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeries: \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cspan style=\"color: #005a9c;\"\u003e\u003cstrong\u003eRX3i PacSystem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e Automation Infrastructure\u003c\/li\u003e\n\u003cli\u003eModule Type: Remote PROFINET CEP Carrier Block\u003c\/li\u003e\n\u003cli\u003eEthernet Interface: Dual RJ-45 10\/100 Base-TX copper receptacles\u003c\/li\u003e\n\u003cli\u003ePROFINET Compliance: Supported PROFINET version 2.3 (Class A specification)\u003c\/li\u003e\n\u003cli\u003eInput Voltage Range: 19.2 to 30 Volts DC operational window\u003c\/li\u003e\n\u003cli\u003eNominal Power Consumption: 5.25 Watts (0.22 Amps at 24 VDC nominal)\u003c\/li\u003e\n\u003cli\u003eStation Module Capacity: Accommodates exactly 1 I\/O module per carrier station\u003c\/li\u003e\n\u003cli\u003eStation I\/O Allocation: 1024 bytes maximum total data per remote station\u003c\/li\u003e\n\u003cli\u003eInput Mapping Threshold: 512 bytes maximum allocated for input variables\u003c\/li\u003e\n\u003cli\u003eOutput Mapping Threshold: 512 bytes maximum allocated for output variables\u003c\/li\u003e\n\u003cli\u003eIntegrated Bit Registers: Provides 32 input status bits and 32 output control bits\u003c\/li\u003e\n\u003cli\u003eLocal Maintenance Interface: 1 USB 2.0 compliant Micro-B connector port\u003c\/li\u003e\n\u003cli\u003ePhysical Unit Dimensions: 177.2 x 51 x 35 mm (7 x 2 x 1.3 inches)\u003c\/li\u003e\n\u003cli\u003eOperating Ambient Temperature: 0 to 60 degrees Celsius operational range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur distributed automation engineers inspected the architecture of the \u003cspan style=\"color: #005a9c;\"\u003e\u003cstrong\u003eIC695CEP001\u003c\/strong\u003e\u003c\/span\u003e remote node device. This network tool facilitates the deployment of isolated single-slot I\/O clusters without installing full-sized multi-slot sub-racks. Because it includes dual RJ-45 copper receptacles, it enables flexible line or ring network topologies directly on the factory floor. It operates efficiently within the high-speed I\/O LAN layer. This setup ensures that decentralized field components communicate with near-zero transmission latency.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGE Fanuc RX3i PacSystem PROFINET Controller Modules\u003c\/li\u003e\n\u003cli\u003eRX3i compatible discrete and analog standalone I\/O modules\u003c\/li\u003e\n\u003cli\u003eProficy Machine Edition engineering software configurations\u003c\/li\u003e\n\u003cli\u003eIndustrial shielded twisted-pair Cat5e\/Cat6 network patch leads\u003c\/li\u003e\n\u003cli\u003eRegulated 24V DC industrial control power supply units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDecentralized conveyor routing sensor aggregation nodes\u003c\/li\u003e\n\u003cli\u003eRemote water processing facility pump monitoring stations\u003c\/li\u003e\n\u003cli\u003eSkid-mounted manufacturing apparatus standalone control interfaces\u003c\/li\u003e\n\u003cli\u003eLocalized HVAC air handler digital data integration loops\u003c\/li\u003e\n\u003cli\u003eAutomotive manufacturing line localized safety interlock tracking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #005a9c;\"\u003e\u003cstrong\u003eIC695CEP001\u003c\/strong\u003e\u003c\/span\u003e utilizes specialized firmware sub-routines to execute advanced remote node module scanning. It intercepts field-side faults and reports status anomalies directly through the 32 integrated input status bits. The dual Ethernet ports provide link verification and speed indicators to isolate physical cabling damage immediately. Technicians execute deep real-time hardware tracking or upload firmware updates quickly by connecting via the front Micro-B USB port.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhich minimum software revision is required to configure this PROFINET carrier?\u003c\/p\u003e\n\u003cp\u003eYou must use Proficy Machine Edition version 8.0 SIM 5 or later to configure the hardware properties.\u003c\/p\u003e\n\u003cp\u003eCan a single carrier module support multiple expansion I\/O blocks concurrently?\u003c\/p\u003e\n\u003cp\u003eNo, this specific CEP carrier station supports exactly one single I\/O module per station setup.\u003c\/p\u003e\n\u003cp\u003eWhat specific function do the 32 input status bits serve during operation?\u003c\/p\u003e\n\u003cp\u003eThey continuously transmit carrier health parameters and internal module error states to the master CPU controller.\u003c\/p\u003e\n\u003cp\u003eIs the front-facing Micro-B USB port used for active runtime communication?\u003c\/p\u003e\n\u003cp\u003eNo, the Micro-B interface is dedicated exclusively to performing local hardware firmware upgrades and diagnostics.\u003c\/p\u003e\n\u003cp\u003eWhat happens if the field input power drops below 19.2 Volts DC?\u003c\/p\u003e\n\u003cp\u003eThe unit undergoes an under-voltage shutdown routine and reports a communication fault to the main controller.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection \u0026amp; Buying Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that your network master module supports PROFINET version 2.3 Class A operations.\u003c\/li\u003e\n\u003cli\u003eEnsure your decentralized node requires only a single I\/O block expansion before ordering.\u003c\/li\u003e\n\u003cli\u003eCalculate the total byte load to ensure data fits within the 512-byte input\/output constraints.\u003c\/li\u003e\n\u003cli\u003eCheck that your 24V DC field electrical lines match the 19.2 to 30 Volts operational window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage List \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x GE Fanuc \u003cspan style=\"color: #005a9c;\"\u003e\u003cstrong\u003eIC695CEP001\u003c\/strong\u003e\u003c\/span\u003e PROFINET CEP Carrier Assembly\u003c\/li\u003e\n\u003cli\u003eFactory Shielded Component Installation Manual Sheet\u003c\/li\u003e\n\u003cli\u003e12-Month Comprehensive Global Warranty Protection Policy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWe dispatch all active in-stock item orders within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003eOur logistical partners utilize premium express couriers: FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003eWe send tracking update notifications to your email immediately upon freight departure.\u003c\/li\u003e\n\u003cli\u003eEvery package features heavy-duty industrial cushioning to safeguard internal electronics.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014007447734,"sku":"IC695CEP001","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695CEP001.jpg?v=1779091120","url":"https:\/\/www.plcsparehub.com\/products\/ic695cep001-ge-fanuc-rx3i-profinet-carrier-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}