{"product_id":"ic695alg704-emerson-ge-pacsystem-rx3i-analog-output-module","title":"IC695ALG704 Emerson GE PACSystem RX3i Analog Output Module","description":"\u003ch3\u003e\u003cstrong\u003eEmerson GE \u003cspan style=\"color: #0056b3;\"\u003eIC695ALG704\u003c\/span\u003e Technical Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Emerson Automation \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC695ALG704\u003c\/span\u003e\u003c\/strong\u003e (formerly manufactured by GE Intelligent Platforms) is a high-accuracy, single-slot analog output module designed for the PACSystem RX3i control platform. This module provides four non-isolated output channels, configurable for voltage or current loops on an individual channel-by-channel basis.\u003c\/p\u003e\n\u003cp\u003eThis module converts digital PLC registers into analog signals (±10 Vdc, 0 to 10 Vdc, 0-20 mA, or 4-20 mA) to drive field actuators. It features a fast 8-millisecond update rate and utilizes high-resolution conversion (up to 15.9 bits) to ensure smooth, step-free modulation. Field wiring connects through compatible box or spring-style terminal blocks, including the IC694TBB032 and IC694TBS032 series.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Emerson \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC695ALG704\u003c\/span\u003e\u003c\/strong\u003e is an industrial standard for process variable replication and modulating control loop execution. Unlike older analog cards that require manual hardware jumpers, this card is entirely software-configured through Machine Edition software. This eliminates physical calibration errors during field deployment.\u003c\/p\u003e\n\u003cp\u003eThe module is equipped with a dedicated output protection network that survives sustained overvoltage conditions up to 30 Vdc. It handles both 32-bit floating-point and scaled 16-bit integer data formats, allowing programmers to bypass complex math conversion blocks in the PLC controller logic.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown (Part Number Structural Tree)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe hardware and modular configuration of the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC695ALG704\u003c\/span\u003e\u003c\/strong\u003e is structured below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC695\u003c\/strong\u003e — \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003ePACSystem RX3i\u003c\/a\u003e High-Performance Backplane Module Platform\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eALG\u003c\/strong\u003e — Analog I\/O Module Group Classification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e704 [This Model]\u003c\/strong\u003e — 4-Channel Non-Isolated Analog Output Module supporting voltage and current ranges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Wiring Assemblies (Sold Separately):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC694TBB032:\u003c\/strong\u003e Standard Box-style terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC694TBB132:\u003c\/strong\u003e Extended Box-style terminal block (provides extra depth for shield grounding wires)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC694TBS032:\u003c\/strong\u003e Tactile Spring-style terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC694TBS132:\u003c\/strong\u003e Extended Spring-style terminal block\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Plant Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003ePneumatic Control Valves:\u003c\/strong\u003e Modulating continuous positioners on steam header and feed-water valve loops.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eVariable Frequency Drives (VFDs):\u003c\/strong\u003e Transmitting speed and torque reference signals directly to drive terminals over 4-20 mA loops.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eDamper and Louver Actuators:\u003c\/strong\u003e Controlling combustion air and exhaust flow dampers in industrial boiler systems.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eSignal Distribution Networks:\u003c\/strong\u003e Providing reconditioned isolation outputs to feed external paper chart recorders and data loggers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; Signal Integrity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eAdvanced Alarm Processing:\u003c\/strong\u003e Monitors and latches critical operational errors, reporting high-high, high, low, and low-low parameter violations.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eActive Hardware Protection:\u003c\/strong\u003e Provides robust overvoltage protection of -30 Vdc for up to 60 seconds and +30 Vdc for up to one hour.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eAuto-Calibration Routines:\u003c\/strong\u003e On-board background diagnostics continuously adjust for thermal component drift, maintaining a 0.15% full-scale accuracy at 25°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Table\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"text-align: left; padding: 10px; font-weight: bold; border-bottom: 2px solid #dee2e6;\"\u003eSpecification Category\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 10px; font-weight: bold; border-bottom: 2px solid #dee2e6;\"\u003eTechnical Parameters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eEmerson Automation (Formerly GE Fanuc)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eFull Part Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC695ALG704\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eBackplane Platform\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003ePACSystem RX3i PCI Universal Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eOutput Channel Count\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e4 Non-Isolated output loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eCurrent Signal Ranges\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e0 to 20 mA and 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eVoltage Signal Ranges\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e±10 Vdc and 0 to 10 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eAnalog Resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e±10V (15.9 bits); 0-10V (14.9 bits); 0-20mA (15.9 bits); 4-20mA (15.6 bits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e375 mA maximum at +3.3 Vdc loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eExternal Power Requirements\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e+19.2 to +30 Vdc (24 Vdc nominal), 120 mA maximum consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eLoad Impedance Limit\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e850 Ohms maximum current loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal Logistics, Delivery \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCourier Networks:\u003c\/strong\u003e Priority global transit handled via express services DHL, FedEx, and UPS loops.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eDispatch SLA:\u003c\/strong\u003e In-stock units are securely packaged and shipped within 24 to 48 hours of verification.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Provided with a complete 12-month replacement warranty from Global PLC Spare HUB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStrategic Procurement \u0026amp; Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCPU Firmware Verification:\u003c\/strong\u003e The \u003cstrong\u003eIC695ALG704\u003c\/strong\u003e requires an RX3i CPU with firmware version 3.0 or later. Confirm your host CPU firmware level before hot-swapping or installing this module.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eExternal Power Routing:\u003c\/strong\u003e This module requires an external +24 Vdc power supply to drive its analog outputs. This power cannot be drawn from the universal backplane TB1 connector; wire it directly to the module's terminal block.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTerminal Block Depth Selection:\u003c\/strong\u003e When using heavy-gauge shielded cable, choose the extended depth terminal blocks (IC694TBB132 or IC694TBS132). The extra space simplifies shield wire routing and helps prevent physical cabinet crowding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Frequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the analog outputs if the RX3i CPU goes into STOP mode or loses communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Through Machine Edition, you can configure each channel to either hold its last state or ramp down to a designated safe value (such as 4 mA or 0 V). This feature helps protect downstream equipment during system faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why are there four separate analog resolution specifications listed for the same card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The internal digital-to-analog converter (DAC) spans a fixed bipolar range. When you configure the channel to a unipolar range (such as 0-10 Vdc or 4-20 mA), the resolution adjusts to maximize accuracy over that narrower span.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support HART protocol communication with smart field instruments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \u003cstrong\u003eIC695ALG704\u003c\/strong\u003e does not support HART pass-through communication. For smart instrument management, select a dedicated RX3i HART analog card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: My field actuator has a high input impedance. Can I still drive a current loop using this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module can drive current loops with total loop resistance up to 850 Ohms. To maintain stable current output, ensure your field cabling and actuator impedance do not exceed this limit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I perform a firmware upgrade on the IC695ALG704 module if my CPU does not have a serial port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: If your CPU lacks a serial interface for the WinLoader utility, you can perform the upgrade using the web-based tool provided in the firmware upgrade kit. Follow the network instructions included in the firmware package.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014007120054,"sku":"IC695ALG704","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695ALG704.jpg?v=1784281959","url":"https:\/\/www.plcsparehub.com\/products\/ic695alg704-emerson-ge-pacsystem-rx3i-analog-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}