{"product_id":"ic695alg628-ge-pacsystem-rx3i-analog-input-module-get-a-quote","title":"IC695ALG628 GE PACSystem RX3i Analog Input Module Get a Quote","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC695ALG628\u003c\/strong\u003e \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e \/ \u003cstrong\u003eEmerson Automation\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003ePACSystem RX3i Analog Input Module\u003c\/strong\u003e delivers high-precision 24-bit resolution measurement across eight single-ended or four differential channels. Equipped with integrated HART Version 5.0 protocol support and dual internal modems, this advanced module seamlessly bridges complex process instrumentation with high-performance control backplanes.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Technical Parameters\u003c\/h3\u003e\n\u003ctable style=\"width: 100.061%; height: 333.238px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 19.6023px;\"\u003e\u003cstrong\u003eSpecification Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 19.6023px;\"\u003e\u003cstrong\u003eTechnical Metric \/ Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 19.6023px;\"\u003eManufacturer \u0026amp; Brand\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 19.6023px;\"\u003eGE Intelligent Platforms \/ Emerson \/ GE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6023px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 19.6023px;\"\u003eCatalog Number \u0026amp; Series\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 19.6023px;\"\u003e\n\u003cstrong\u003eIC695ALG628\u003c\/strong\u003e (\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003ePACSystem RX3i Series\u003c\/strong\u003e\u003c\/a\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 39.2045px;\"\u003eModule Type \u0026amp; Channels\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 39.2045px;\"\u003eAnalog Input with HART; 8 single-ended or 4 differential non-isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 39.2045px;\"\u003eSupported Voltage Ranges\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 39.2045px;\"\u003e±10 VDC, 0-10 VDC, ±5 VDC, 0-5 VDC, 1-5 VDC, ±50 mV, ±150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 39.2045px;\"\u003eSupported Current Ranges\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 39.2045px;\"\u003e0-20 mA, 4-20 mA, ±20 mA (249 Ω ±1% current input resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 39.2045px;\"\u003eA\/D Conversion \u0026amp; Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 39.2045px;\"\u003e24-bit ADC converted to IEEE 32-bit floating point or 16-bit integer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 39.2045px;\"\u003eHART Communication\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 39.2045px;\"\u003eHART Protocol Version 5.0 with Two (2) internal HART modems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 39.2045px;\"\u003eBackplane Power Draw\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 39.2045px;\"\u003e330 mA max @ 5.0V; 600 mA max @ 3.3V; Max power dissipation 4.83 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2045px;\"\u003e\n\u003ctd style=\"width: 29.302%; height: 39.2045px;\"\u003eDiagnostic \u0026amp; Protection Limits\u003c\/td\u003e\n\u003ctd style=\"width: 67.9789%; height: 39.2045px;\"\u003eOvervoltage ±60 VDC continuous; Overcurrent ±28 mA continuous max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cstrong\u003eIC695ALG628\u003c\/strong\u003e module directly into the universal backplane of an RX3i system. Terminate field wiring using box-style (IC694TBB032), extended box-style (IC694TBB132), spring-style (IC694TBS032), or extended spring-style (IC694TBS132) terminal blocks. Utilize extended terminal blocks when employing shielded cables to gain necessary shroud depth and noise immunity.\u003c\/p\u003e\n\u003ch3\u003eDebugging and Maintenance Convenience\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: Built-in autocalibration executes automatically upon every power-up cycle to maintain measurement accuracy. Software-configurable alarm thresholds (High, Low, High-High, Low-Low, and Rate of Change) allow engineers to catch sensor degradation early without physical jumper modifications.\u003c\/p\u003e\n\u003ch3\u003eCompatibility and Environmental Standards\u003c\/h3\u003e\n\u003cp\u003eFully compatible with Machine Edition version 5.0 SP3 and later programming environments, this module operates reliably from 32°F to 140°F (0°C to 60°C) under 5% to 95% non-condensing humidity. Flash memory architecture supports straightforward firmware upgrades for long-term system maintainability.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents, Warranty, and Logistics\u003c\/h3\u003e\n\u003cp\u003eThe shipment includes the \u003cstrong\u003eIC695ALG628\u003c\/strong\u003e analog input module (terminal blocks sold separately). Global PLC Spare HUB backs this precision instrument with a dependable 12-month warranty. All orders dispatch swiftly within 24 to 48 hours via premium global logistics partners including FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003ch3\u003eTarget Applications and Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision chemical dosing flow rate tracking via 4-20mA HART transmitters\u003c\/li\u003e\n\u003cli\u003eRefinery pressure transmitter diagnostics and remote device configuration\u003c\/li\u003e\n\u003cli\u003ePower generation temperature and multi-variable sensor data acquisition\u003c\/li\u003e\n\u003cli\u003eWater treatment facility level monitoring with open-circuit fault detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guide and Engineering Advice\u003c\/h3\u003e\n\u003cp\u003eWhen engineering HART loops, configure channel current ranges explicitly to 4-20 mA to ensure proper digital signal overlay. Verify that total backplane current consumption does not exceed power supply limits, particularly when combining high-draw HART modules on a single RX3i rack.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does the module require extended terminal blocks like the IC694TBB132 in heavy industrial skids?\u003c\/strong\u003e\u003cbr\u003eA: Extended terminal blocks provide extra shroud depth required to properly terminate bulky braided shielding wires, preventing ground loops and electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do internal HART modems manage data polling across eight single-ended channels?\u003c\/strong\u003e\u003cbr\u003eA: The module utilizes two internal HART modems multiplexed across active channels to poll digital process variables without interrupting core analog scan cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What triggers a 1-second maximum open circuit detection alert on current inputs?\u003c\/strong\u003e\u003cbr\u003eA: If loop continuity breaks or transmitter power fails, dropping current below operational thresholds, the module flags an open-circuit fault within 1 second.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 24-bit resolution data format be changed dynamically via control logic?\u003c\/strong\u003e\u003cbr\u003eA: Yes, output data format is fully software configurable, allowing selection between IEEE 32-bit floating point or 16-bit integer values packed inside a 32-bit register.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What preventive steps minimize signal fluctuation on long analog input wire runs?\u003c\/strong\u003e\u003cbr\u003eA: Operators should select appropriate configurable input filter settings (ranging from 8 Hz to 500 Hz) to smooth out high-frequency plant electrical noise.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013996011702,"sku":"IC695ALG628","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695ALG628.jpg?v=1785316704","url":"https:\/\/www.plcsparehub.com\/products\/ic695alg628-ge-pacsystem-rx3i-analog-input-module-get-a-quote","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}