{"product_id":"ic695alg616-emerson-ge-fanuc-pacsystem-rx3i-analog-input-module","title":"IC695ALG616 Emerson GE Fanuc PACSystem RX3i Analog Input Module","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC695ALG616\u003c\/strong\u003e is a high-density, non-isolated analog input module manufactured by \u003cstrong style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/strong\u003e (formerly \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/strong\u003e) for the \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003ePACSystem RX3i\u003c\/strong\u003e\u003c\/a\u003e control architecture. Engineered for high-precision process signal acquisition, this universal module features a 24-bit Analog-to-Digital Converter (ADC) capable of processing dynamic current and voltage field inputs across high-speed industrial applications.\u003c\/p\u003e\n\u003cp\u003eOperating without hardware jumpers or DIP switches, the \u003cstrong style=\"color: #0056b3;\"\u003eIC695ALG616\u003c\/strong\u003e is fully configured through Proficy Machine Edition (PME). The module supports 16 single-ended or 8 differential channels, converting analog field variables into IEEE 32-bit floating-point or 16-bit integer formats with software-selectable low-pass digital filtering and automatic power-up calibration.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eHardware Feature Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePACSystem RX3i Universal Backplane Bus Interface\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-speed PCI backplane communication providing 3.3VDC (450mA) and 5VDC (600mA) internal power extraction.\u003c\/li\u003e\n\u003cli\u003eOnboard flash memory for firmware updates and software configuration storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFlexible Channel Density \u0026amp; Architecture\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSixteen (16) Single-Ended Channels:\u003c\/b\u003e Optimized for common-ground instrument loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEight (8) Differential Channels:\u003c\/b\u003e Provides maximum noise rejection for long-distance field wiring runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMulti-Range Input Signal Compatibility\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCurrent Modes:\u003c\/b\u003e 0 to 20 mA, 4 to 20 mA, ±20 mA (Internal 249 Ω ±1% precision shunt resistor).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVoltage Modes:\u003c\/b\u003e ±10 VDC, 0 to 10 VDC, ±5 VDC, 0 to 5 VDC, 1 to 5 VDC, ±150 mV, ±50 mV.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTri-Color LED Status Diagnostics\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eModule OK LED:\u003c\/b\u003e Indicates overall module health and backplane power status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eField Status LED:\u003c\/b\u003e Reports field wiring faults, overrange conditions, or channel errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTerminal Block (TB) LED:\u003c\/b\u003e Tracks physical insertion or removal of the terminal block connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003eIC695ALG616\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer \u0026amp; Brand\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/strong\u003e \/ \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eControl Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003ePACSystem RX3i\u003c\/strong\u003e Automation Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModule Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated Universal Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eChannel Configuration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Single-Ended or 8 Differential Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eADC Conversion Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e24-Bit Sigma-Delta Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput Data Representation\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 32-Bit Floating Point or 16-Bit Integer in 32-Bit Field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSelectable Input Filters\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Hz, 12 Hz, 16 Hz, 40 Hz, 200 Hz, 500 Hz Cutoff Frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eVoltage Input Impedance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 kΩ High Impedance State\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCurrent Shunt Resistance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e249 Ω ±1% Internal Precision Resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOvervoltage Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±60 VDC Continuous Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOvercurrent Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±28 mA Continuous Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOpen Circuit Detection Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 Second Maximum Response Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAuto-Calibration Cycle\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatically Executed at Power-Up Startup Routine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperating Temperature Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eStorage Temperature Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eVibration Resistance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10-57 Hz @ 0.0524 mm Peak \/ 15 G @ 11 ms Shock (IEC 60068-2-6 \/ 2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities \u0026amp; Signal Integrity\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMulti-Tier Threshold Alarms:\u003c\/b\u003e Programmable Very High, High, Low, and Very Low alarm thresholds on a per-channel basis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRate-of-Change Monitoring:\u003c\/b\u003e Detects rapid signal shifts via positive and negative rate alarms to flag process anomalies before hardware failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLive Hardware Fault Reporting:\u003c\/b\u003e Automatically transmits open-circuit line faults, overcurrent conditions, and missing terminal block status directly to the RX3i CPU fault table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIn-Situ Auto-Calibration:\u003c\/b\u003e Internal reference calibration on power-up maintains precision without requiring external precision voltage generators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTarget Application Scenarios \u0026amp; Equipment\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePetrochemical \u0026amp; Gas Processing:\u003c\/b\u003e Acquires pressure transmitter (4-20mA) and temperature sensor signals across refined fuel distribution racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTurbomachinery Speed \u0026amp; Throttle Monitoring:\u003c\/b\u003e Handles ±10V feedback signals from electro-hydraulic valve positioners on steam turbines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWater \u0026amp; Wastewater Treatment:\u003c\/b\u003e Monitors flowmeters, pH analyzers, and tank level transmitters across municipal treatment grids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Field Wiring Best Practices\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDifferential Wiring Noise Suppression:\u003c\/b\u003e For long-distance instrumentation runs, select 8-channel differential mode to reject common-mode ground noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCurrent Loop Termination:\u003c\/b\u003e When configuring current inputs (4-20mA), ensure internal software shunt switches are enabled in Proficy Machine Edition to route signals across the 249 Ω resistor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTerminal Block Insertion:\u003c\/b\u003e Verify proper seating of the removable terminal block (RTB); observe the TB LED to ensure field connections are recognized by the backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003ePackaging, Logistics \u0026amp; Warranty Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch Lead Time:\u003c\/b\u003e In-stock units dispatched within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGlobal Express Couriers:\u003c\/b\u003e Fast international shipping via DHL Express, FedEx, and UPS Priority.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFactory Packaging:\u003c\/b\u003e Supplied 100% Brand New and Original in sealed anti-static factory boxing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e12-Month Coverage:\u003c\/b\u003e Backed by a comprehensive 12-month quality replacement warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eEngineering Buyer's Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eVerify Backplane Current Budget:\u003c\/b\u003e Ensure the RX3i power supply meets the combined 450mA (3.3V) and 600mA (5V) draw of this module alongside existing rack cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMatch Signal Filtering to Process Dynamics:\u003c\/b\u003e Set input filters to 8 Hz or 12 Hz for noisy slow-moving temperature loops, or up to 500 Hz for dynamic hydraulic feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConfirm PME Software Version:\u003c\/b\u003e Ensure your Proficy Machine Edition programming environment supports the IC695 ALG series target definitions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: How does the module handle a severed 4-20mA sensor cable in the field?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The onboard open-circuit detection trips within 1 second, asserting a channel fault status bit and turning on the red Field Status LED.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Is it necessary to manually calibrate this module using precision voltage sources during annual maintenance?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, internal autocalibration runs automatically at power-up; routine verification can be performed without adjusting physical pot trimmers.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can I mix voltage and current input signals on different channels on the same card?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, each input channel is individually software-configurable in Proficy Machine Edition for independent voltage or current signal ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What causes the Terminal Block (TB) LED to illuminate red or remain unlit?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: A red or unlit TB LED indicates the removable terminal block is either loose, improperly seated, or missing from the front housing.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How does non-isolated architecture affect field ground loop design?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Because channels share a common internal return, loop isolators or differential wiring must be used if field sensors operate on different ground potentials.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring an emergency retrofit at a glass manufacturing facility, engineers experienced severe measurement flutter on a cooling line temperature loop. The existing analog card suffered from ground loop currents and noise induction caused by adjacent variable frequency drives.\u003c\/p\u003e\n\u003cp\u003eOur technical team advised deploying the \u003cstrong style=\"color: #0056b3;\"\u003eIC695ALG616\u003c\/strong\u003e configured in 8-channel differential mode with a 16 Hz low-pass filter enabled in Proficy Machine Edition. The differential configuration canceled out 3.5V of common-mode ground noise instantly, while the 24-bit ADC delivered smooth, highly accurate temperature readings. The plant restored furnace control stability without adding costly external signal isolators.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013995978934,"sku":"IC695ALG616","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695ALG616-3.jpg?v=1789013423","url":"https:\/\/www.plcsparehub.com\/products\/ic695alg616-emerson-ge-fanuc-pacsystem-rx3i-analog-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}