{"product_id":"ic695alg112-ge-fanuc-pacsystems-rx3i-analog-input-module-unit","title":"IC695ALG112 GE Fanuc PACSystems RX3i Analog Input Module Unit","description":"\u003ch3\u003e\u003cstrong\u003eEngineering Architecture \u0026amp; System Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695ALG112\u003c\/strong\u003e\u003c\/span\u003e is a high-performance analog input module engineered by \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc \/ Emerson Automation\u003c\/strong\u003e\u003c\/span\u003e for the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePACSystems RX3i Series\u003c\/strong\u003e\u003c\/span\u003e. Designed to acquire precision process telemetry, this module features twelve single-ended isolated channels capable of processing unipolar\/bipolar voltage ranges and standard current loops with 16-bit analog-to-digital conversion.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications \u0026amp; Operational Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003e\u003cstrong\u003ePerformance Attribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc \/ Emerson Automation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695ALG112\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003ePACSystems RX3i\u003c\/a\u003e Analog Input Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 Single-ended isolated input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC, -10 to +10 VDC, ±5 VDC, 0 to 5 VDC, 1 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 to 20 mA, ±20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog-to-Digital Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit ADC (Configurable as IEEE 32-bit floating point or 16-bit integer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreater than 500 kΩ for voltage inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Filter Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable at 8 Hz, 12 Hz, 16 Hz, 40 Hz, 250 Hz, and 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibrated Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% of range @ 25°C; 0.2% over full temperature span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower \u0026amp; Thermal Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 4.89W power consumption with 20 mA inputs; zero thermal derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Operating Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e\u003c\/span\u003e Withstands continuous overvoltage up to ±35 VDC and overcurrent up to ±35 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eOpen Circuit Detection:\u003c\/strong\u003e\u003c\/span\u003e Automatically flags open-circuit loop faults within a 1-second maximum response window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eFirmware Upgrades:\u003c\/strong\u003e\u003c\/span\u003e Supports flash memory updates for seamless field maintenance and feature expansions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Controller Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRX3i PAC Backplanes:\u003c\/strong\u003e Directly mounts into PACSystems RX3i universal backplane chassis racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Transmitters:\u003c\/strong\u003e Interfaces with 4-20mA pressure transmitters, flow meters, thermocouples (via conditioners), and RTD sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupervisory Control Nodes:\u003c\/strong\u003e Feeds conditioned telemetry data into HMI, SCADA, and DCS monitoring nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Controllers:\u003c\/strong\u003e Provides real-time process variables for advanced PID control algorithms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Applications \u0026amp; Diagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695ALG112\u003c\/strong\u003e\u003c\/span\u003e handles rigorous analog signal conditioning across continuous process and power generation facilities:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePrecision Flow \u0026amp; Pressure Tracking:\u003c\/strong\u003e\u003c\/span\u003e Converts raw analog voltage and current loops into stable digital inputs for fluid control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSoftware Selectable Filtering:\u003c\/strong\u003e\u003c\/span\u003e Eliminates line noise and signal bounce by tuning digital filter frequencies from 8 Hz up to 1000 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003ePredictive Startup Diagnostics:\u003c\/strong\u003e\u003c\/span\u003e Built-in routine checks perform hardware self-diagnostics during power-up and runtime operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eFlexible Data Formatting:\u003c\/strong\u003e\u003c\/span\u003e Outputs data directly in IEEE 32-bit floating-point or 16-bit integer formats to match PLC math registers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom an instrumentation engineering perspective, deploying the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC695ALG112\u003c\/strong\u003e\u003c\/span\u003e requires careful tuning of the digital filter settings. While lower filter frequencies (such as 8 Hz) maximize noise rejection in electrically noisy plant environments, they increase step-response settling times up to 127 ms. For high-speed control loops, switching to 250 Hz or 1000 Hz filters reduces settling latency down to 0-3.1 ms, though shielding integrity must be strictly maintained to prevent RF interference degradation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics, Fulfillment \u0026amp; Quality Guarantee\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition Status:\u003c\/strong\u003e 100% Brand New and Original Factory Sealed Inventory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Lead Time:\u003c\/strong\u003e Guaranteed order processing and dispatch within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Logistics:\u003c\/strong\u003e Secure worldwide air transit delivered via FedEx, UPS, or DHL with end-to-end tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Assurance:\u003c\/strong\u003e Fully protected by a comprehensive 12-Month Factory Defect Warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I handle routine calibration requirements to maintain the 0.1% accuracy specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module recommends a 12-month calibration interval, during which software offset adjustments can be applied periodically to compensate for component drift over time without physical trimmers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the impact of choosing an 8 Hz digital filter versus a 1000 Hz filter on step response?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: An 8 Hz filter provides high noise suppression but results in a 127 ms step-response settling time, whereas a 1000 Hz filter achieves an instantaneous 0 ms settling time at the expense of higher noise bandwidth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How does the module handle a severed sensor wire or open-circuit condition?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The built-in open-circuit detection circuitry flags and reports the fault status to the RX3i CPU within a maximum response window of 1 second.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why should I configure input data as IEEE 32-bit floating-point instead of 16-bit integer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Floating-point formatting retains decimal precision automatically, eliminating the need for manual scaling math blocks inside your ladder logic program when converting raw counts to engineering units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What guidelines should I follow when selecting input types between unipolar voltage and current loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Use current loops (4-20 mA) for long-distance signal transmission to minimize voltage drop over cable runs, and reserve unipolar voltage (0-10 VDC) for short cabinet-level connections.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014006562998,"sku":"IC695ALG112","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC695ALG112.jpg?v=1784621031","url":"https:\/\/www.plcsparehub.com\/products\/ic695alg112-ge-fanuc-pacsystems-rx3i-analog-input-module-unit","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}