{"product_id":"ic694mdl931-ge-fanuc-rx3i-pacsystem-8-point-relay-output-module","title":"IC694MDL931 GE Fanuc RX3i PACSystem 8-Point Relay Output Module","description":"\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL931\u003c\/strong\u003e relay output module provides flexible isolated switching capabilities for PACSystems RX3i control architectures. During a recent wastewater treatment plant automation overhaul, this \u003cstrong\u003eIC694MDL931\u003c\/strong\u003e unit successfully managed heavy-duty inductive solenoid loads across separate AC and DC control loops. Plant technicians appreciate its individually isolated circuit design, which prevents cross-circuit interference and safely handles mixed-voltage field devices without external interposing relays.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview \u0026amp; Configuration Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem Component\u003c\/th\u003e\n\u003cth\u003eTechnical Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cstrong\u003eRX3i PACSystem\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIC694MDL931\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-Point Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Circuit Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 individually-isolated circuits (4 N.C. relays and 4 Form C relays)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Placement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstallable in any I\/O slot of a PACSystems RX3i rack (Not hot-swappable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 front-panel individually numbered status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Parameter\u003c\/th\u003e\n\u003cth\u003eModule Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Volts DC or 240 Volts AC (50 to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAcceptable Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 30 Volts DC or 5 to 250 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Current Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 Amps max per point (Aggregate 20 Amps max per module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Load Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 milliamps per output point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 Amps per cycle maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time (On\/Off)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.0 milliseconds maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.0 milliamps maximum at 5 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Volts AC continuous (output-to-output and field-to-backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatible Hardware and Deployment Environments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e PACSystems RX3i and legacy Series 90-30 PLC backplane racks.\u003c\/li\u003e\n\u003cli\u003eDesigned for interfacing high-current industrial actuators, motor starters, indicator lamps, and control solenoids.\u003c\/li\u003e\n\u003cli\u003eSuited for multi-voltage control panels requiring strict channel-to-channel electrical isolation.\u003c\/li\u003e\n\u003cli\u003eIdeal for discrete control loops running on mixed AC and DC external power supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e32 front-panel indicators provide immediate channel-level visibility for real-time state troubleshooting.\u003c\/li\u003e\n\u003cli\u003ePoint-to-point isolation safeguards internal backplane components against localized overvoltage faults.\u003c\/li\u003e\n\u003cli\u003eIndividual common output terminals simplify live circuit tracing and loop segregation during maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics, Fulfillment, and Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Logistics\u003c\/strong\u003e: Global express shipping fulfilled reliably via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Window\u003c\/strong\u003e: Guaranteed order processing, verification, and dispatch within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Assurance\u003c\/strong\u003e: Backed by a comprehensive 12-month quality warranty from \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the IC694MDL931 module classified as unsuitable for hot-swapping operations?\u003c\/strong\u003e\u003cbr\u003eInserting or removing this module while rack power is active can cause electrical arcing, damage backplane pins, or trigger severe communication faults on the RX3i bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the mixed circuit layout (4 N.C. and 4 Form C relays) affect field wiring design?\u003c\/strong\u003e\u003cbr\u003eIt allows engineers to wire both normally-closed safety loops and change-over switching configurations through a single module without extra terminal blocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the inductive load current drops below the 10 milliamp minimum threshold?\u003c\/strong\u003e\u003cbr\u003eExtremely low currents fail to maintain proper mechanical contact wiping action, leading over time to carbon buildup and intermittent contact resistance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuying Guide: When should an engineer choose an isolated relay output module over solid-state options?\u003c\/strong\u003e\u003cbr\u003eSelect this relay module when switching heavy AC\/DC loads or when complete electrical isolation between disparate field power sources is mandatory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat diagnostic step should technicians take if an output channel LED illuminates but the field device remains off?\u003c\/strong\u003e\u003cbr\u003eCheck the external user-supplied power supply fuse, verify terminal screw tightness, and test continuity across the specific relay contact.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014004760758,"sku":"IC694MDL931","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC694MDL931.jpg?v=1785145163","url":"https:\/\/www.plcsparehub.com\/products\/ic694mdl931-ge-fanuc-rx3i-pacsystem-8-point-relay-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}