{"product_id":"ic694mdl930-pacsystems-rx3i-series-relay-output-module-ge-fanuc","title":"IC694MDL930 PACSystems RX3i Series Relay Output Module GE Fanuc","description":"\u003cdiv\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC694MDL930\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eRelay Output module\u003c\/strong\u003e\u003c\/span\u003e delivers flexible switching control for mixed-voltage industrial automation environments. Global PLC Spare HUB's Insight highlights this 8-channel individually isolated module for its ability to handle both 24VDC and 120\/240VAC loads simultaneously without cross-circuit interference. Maintenance engineers rely on its dry-contact Form A architecture to safely interface controllers with heavy-duty field actuators.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specification Matrix\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson Automation (GE Intelligent Platforms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Catalog No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC694MDL930\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e \/ \u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eRelay Output module\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEight (8) Individually Isolated Form A (Normally Open, N.O.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 30 VDC or 5 to 250 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 Amps resistive per point; 2.0 Amps pilot duty per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Load Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.0 mA at 5VDC; 70 mA at 24VDC relay power bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 15 milliseconds (On \/ Off switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute (Field to Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Lifespan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50,000 to 1,000,000 operations depending on load type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure \u0026amp; Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRX3i PLC I\/O Slots \/ Series 90-30 baseplate compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeployment Architecture \u0026amp; Wiring Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC694MDL930\u003c\/strong\u003e\u003c\/span\u003e directly into standard I\/O slots on the RX3i or Series 90-30 backplane.\u003c\/li\u003e\n\u003cli\u003eEnsure each of the eight isolated outputs utilizes its own common terminal for independent voltage zoning.\u003c\/li\u003e\n\u003cli\u003eProvide an external 24VDC or 120\/240VAC power source to energize connected field actuators.\u003c\/li\u003e\n\u003cli\u003eVerify that inductive loads include proper external suppression circuits since internal snubbers are omitted.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Diagnostics \u0026amp; Operational Health\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFront-panel LED indicators display real-time individual energization status for all output channels.\u003c\/li\u003e\n\u003cli\u003ePoint-to-point isolation prevents electrical faults on a single channel from propagating across the backplane.\u003c\/li\u003e\n\u003cli\u003eInternal registers track operating cycles to help predict relay contact wear over extended runtimes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Applications \u0026amp; Compatible Equipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Controllers:\u003c\/strong\u003e PACSystems RX3i CPU racks and legacy Series 90-30 baseplates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Actuators:\u003c\/strong\u003e Interfacing control systems with heavy-duty motor starters, solenoids, and indicators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Skids:\u003c\/strong\u003e Managing mixed AC and DC control loops within automated fluid handling skids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e Switching high-voltage safety interlocks and discrete manufacturing line loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFulfillment, Warranty \u0026amp; Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogistics Partners:\u003c\/strong\u003e Fast global dispatch handled securely via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Window:\u003c\/strong\u003e Verified orders ship out within 24 to 48 hours of processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Assurance:\u003c\/strong\u003e Backed by an industry-standard 12-month replacement warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does the \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC694MDL930\u003c\/strong\u003e\u003c\/span\u003e require external suppression for inductive loads?\u003c\/strong\u003e\u003cbr\u003eA: This module is engineered without built-in RC snubbers or fuses. Technicians must install external diodes for DC loads or MOV circuits for AC loads to prevent arcing and premature contact degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix 24VDC and 240VAC devices on adjacent channels of this module?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Because all eight output points feature individual channel isolation with separate commons, entirely different voltage levels and types can be safely wired side by side.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What causes chattering or failure to latch on a connected relay output point?\u003c\/strong\u003e\u003cbr\u003eA: Chattering typically happens when the switched load current falls below the 10 mA minimum threshold requirement, preventing a stable electrical wiping contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I calculate total power consumption when adding this unit to an RX3i rack?\u003c\/strong\u003e\u003cbr\u003eA: Account for both the 6 mA draw from the 5VDC logic bus and the 70 mA draw from the 24VDC relay power bus when all eight outputs are simultaneously energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module backward compatible with older Series 90-30 hardware architectures?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the module physical profile supports installation on compatible Series 90-30 baseplates alongside RX3i distributed I\/O drop configurations.\u003c\/p\u003e\n\u003ch3\u003ePurchasing Guide\u003c\/h3\u003e\n\u003cp\u003eWhen selecting the \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC694MDL930\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #2980b9;\"\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #27ae60;\"\u003e\u003cstrong\u003eRelay Output module\u003c\/strong\u003e\u003c\/span\u003e, confirm your panel's maximum current limits and load types. Global PLC Spare HUB recommends reviewing your cabinet's thermal dissipation and keeping spare external interposing protection devices on hand for rapid field deployment.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014004727990,"sku":"IC694MDL930","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC694MDL930.jpg?v=1784706695","url":"https:\/\/www.plcsparehub.com\/products\/ic694mdl930-pacsystems-rx3i-series-relay-output-module-ge-fanuc","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}