{"product_id":"ic694mdl340-emerson-pacsystem-rx3i-16-ch-120vac-output-module","title":"IC694MDL340 Emerson PACSystem RX3i 16-Ch 120VAC Output Module","description":"\u003ch3\u003e\u003cstrong\u003eArchitectural Overview \u0026amp; Switching Topology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC694MDL340\u003c\/strong\u003e engineered originally by \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/strong\u003e \/ \u003cstrong style=\"color: #0056b3;\"\u003eGE Intelligent Platforms\u003c\/strong\u003e and currently supported by \u003cstrong style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/strong\u003e operates as a high-density discrete output module within the \u003cstrong style=\"color: #0056b3;\"\u003ePACSystem RX3i\u003c\/strong\u003e programmable automation controller platform. This module provides sixteen (16) AC output points arranged in two (2) isolated groups of eight (8) channels, driving 120 VAC industrial loads with robust optical isolation and integrated transient suppression.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eComprehensive Technical Specifications Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cstrong\u003eEngineering Parameter\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eOperational Specification\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer \u0026amp; Brand Heritage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/strong\u003e \/ \u003cstrong style=\"color: #0056b3;\"\u003eEmerson Automation\u003c\/strong\u003e (\u003cstrong style=\"color: #0056b3;\"\u003eGE Intelligent Platforms\u003c\/strong\u003e)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Number \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eIC694MDL340\u003c\/strong\u003e \/ \u003cstrong style=\"color: #0056b3;\"\u003ePACSystem RX3i\u003c\/strong\u003e\n\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Classification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDiscrete AC Output Module (16 Channels)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e120 Volts AC (50\/60 Hz operating frequency range: 47 to 63 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Signal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e85 to 132 Volts AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 output points split into 2 isolated groups of 8 channels each\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 Amperes per individual point; 3.0 Amperes maximum per group\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 mA per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 Amperes peak for duration of 1 full AC cycle\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 Volts maximum at rated current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOff-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mA maximum at rated operating voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSwitching Response Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eON response: ≤ 1 ms maximum; OFF response: ≤ 1\/2 cycle maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackplane Power Draw\u003c\/td\u003e\n      \u003ctd\u003e315 mA nominal from the +5V DC bus (all outputs energized)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eGalvanic Isolation Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e250 VAC continuous group-to-group isolation; 1500 VAC dielectric test for 1 minute\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOnboard Group Fusing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTwo (2) pre-installed 3A fuses (Replacement part equivalent: GE Fanuc 44A724627-111)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Thermal Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 °C to +60 °C (+32 °F to +140 °F) cabinet environment\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Resilience \u0026amp; Mechanical Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 °C to +85 °C (-40 °F to +185 °F) non-operating threshold.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing tolerance in industrial control enclosures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration Tolerance:\u003c\/strong\u003e 10 to 57 Hz with 0.0524 mm (0.006 inches) peak displacement.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 15 G peak acceleration maintained for 11 milliseconds duration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation, Wiring \u0026amp; Commissioning Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Sourcing:\u003c\/strong\u003e Provide clean, user-supplied 120 VAC power sources to each isolated group common terminal, allowing multi-phase or single-phase field wiring configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransient Suppression:\u003c\/strong\u003e Rely on the onboard built-in RC snubbers across each output group to suppress inductive kickback and electrical noise generated by solenoids and contactors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus Diagnostics:\u003c\/strong\u003e Observe individual green channel LEDs for real-time output switching verification, and monitor the dedicated red \"F\" diagnostic LED to detect blown group fuses instantly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot-Insertion Protocol:\u003c\/strong\u003e Power down the RX3i backplane rack before sliding or securing the \u003cstrong style=\"color: #0056b3;\"\u003eIC694MDL340\u003c\/strong\u003e module into position to prevent connector arcing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc \/ Emerson IC694MDL340\u003c\/strong\u003e PACSystem RX3i Output Module\u003c\/li\u003e\n  \u003cli\u003e2 × Pre-installed 3A Group Protection Fuses\u003c\/li\u003e\n  \u003cli\u003e1 × Hardware Installation \u0026amp; Safety Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eEngineering FAQ \u0026amp; Field Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Why do connected inductive loads flicker or remain weakly energized when the output channel turns OFF?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e High off-state leakage current (up to 2 mA) flowing through small interposing relays or pilot lights can sustain coil holding current. Add a parallel RC load resistor or dummy bleed resistor across the field terminals to drain residual leakage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What occurs if a field short-circuit exceeds the 3 Ampere group current threshold?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e The corresponding pre-installed group fuse (compatible with GE part 44A724627-111) will blow instantly to protect the internal switching circuitry. Inspect field wiring for insulation faults before replacing the fuse and re-energizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can the two output groups be connected to completely separate AC power supply phases?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Yes. The module features complete group-to-group optical and electrical isolation rated at 250 VAC continuous, allowing Group 1 and Group 2 to operate on entirely independent 120 VAC supply lines or phases.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: How should technicians troubleshoot a persistent fault (\"F\") LED on the front faceplate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e The \"F\" LED illuminates primarily when an internal fuse is blown due to an overcurrent condition or shorted field load. Check continuity across both group fuses and verify that active channel current does not exceed the 0.5A point limit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: Does this output module require external dc control power from the backplane rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA5:\u003c\/strong\u003e The module draws 315 mA strictly from the rack's +5V DC backplane bus to power its internal logic and isolation barriers, while all field-side switching power for connected loads must be supplied externally via user AC lines.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45013986902198,"sku":"IC694MDL340","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC694MDL340-1.jpg?v=1794983702","url":"https:\/\/www.plcsparehub.com\/products\/ic694mdl340-emerson-pacsystem-rx3i-16-ch-120vac-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}