{"product_id":"ic694mdl330-ge-fanuc-rx3i-ac-output-module-shop-now","title":"IC694MDL330 GE Fanuc RX3i AC Output Module | Shop Now","description":"\u003ch4\u003eGlobal PLC Spare HUB's Insight\u003c\/h4\u003e\n\u003cp\u003eIndustrial switching applications requiring multi-phase AC isolation demand high-reliability output modules. The \u003cstrong\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eIC694MDL330\u003c\/span\u003e\u003c\/strong\u003e module provides eight discrete AC output points divided into two isolated groups of four, allowing engineers to manage separate AC power supply phases safely. Field experience indicates that utilizing the integrated RC snubbers per output point significantly suppresses transient electrical noise and extends actuator contact life in high-inductive relay switching environments.\u003c\/p\u003e\n\u003ch4\u003eTechnical Architecture and Specifications Matrix\u003c\/h4\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eEngineering Parameter\u003c\/th\u003e\n\u003cth\u003eTechnical Specification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand and Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003ePACSystems RX3i Series\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eIC694MDL330\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-Point AC Discrete Output Module (Isolated Groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated \u0026amp; Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 Volts AC nominal; 85 to 264 Volts AC operational range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Output Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 Amperes per point with 20 Amps max inrush per cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 to 60 Hertz AC line frequency compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Grouping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 output points split into 2 isolated groups of 4 points with separate commons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Tolerances\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degrees Celsius operating; 5 to 95 percent non-condensing humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eHardware Configuration Layout Tree\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRX3i System Integration Architecture:\u003c\/strong\u003e PACSystems Modular Backplane\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Compatibility:\u003c\/strong\u003e Installs into any standard I\/O slot within an RX3i PLC baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Protection:\u003c\/strong\u003e Each common group is safeguarded by an integrated 5 Amp rated protective fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Suppression:\u003c\/strong\u003e Built-in RC snubber networks installed across every individual output point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirement:\u003c\/strong\u003e Requires user-supplied AC power; strict AC-only operation format (DC power unsupported)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eDiagnostics, Protection, and Logistics Terms\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e Internal group fuse protection and modular channel isolation prevent cascading failures across multi-phase plant networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient Protection:\u003c\/strong\u003e Equipped with built-in RC snubbers to mitigate back-EMF and electrical noise during inductive load de-energization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e Secure, expedited global logistics managed through trusted carriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Window:\u003c\/strong\u003e Standard processing ensures dispatch from the warehouse within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Warranty:\u003c\/strong\u003e Backed by a comprehensive 12-month operational quality assurance warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatible Equipment and Target Application Scenarios\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Controllers:\u003c\/strong\u003e GE Fanuc PACSystems RX3i CPU and modular rack backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Motor Starters \u0026amp; Contactors:\u003c\/strong\u003e Direct switching of heavy-duty industrial AC motor control relays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid Valve Manifolds:\u003c\/strong\u003e Managing 120V\/240V AC fluid control valves in automated process plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Warning Horns \u0026amp; Strobe Lights:\u003c\/strong\u003e Driving high-voltage line-powered safety notification devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSelection Guide and Engineering Advice\u003c\/h4\u003e\n\u003cp\u003eWhen deploying the \u003cstrong\u003e\u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eIC694MDL330\u003c\/span\u003e\u003c\/strong\u003e, remember that the module does not supply internal power to loads; external user-supplied AC sources are mandatory. Because the two 4-point groups feature isolated commons, you can safely power Group 1 from a 120V AC phase and Group 2 from a separate 240V AC phase within the same rack, provided proper wiring separation is maintained.\u003c\/p\u003e\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eCan the \u003cspan style=\"color: #0056b3; font-weight: bold;\"\u003eIC694MDL330\u003c\/span\u003e module operate using a DC control voltage source?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this specific module is strictly designed for AC power supplies and cannot function or switch DC voltage loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the isolated channel commons benefit multi-phase power distribution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe split 4-point groups allow engineers to run different AC phases or distinct voltage levels through the same module without creating electrical cross-interference between groups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the built-in RC snubber networks on each output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe RC snubbers absorb transient voltage spikes generated when inductive loads like solenoids or motor starters turn off, protecting internal switching components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the internal commons protected against overcurrent conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach isolated common group is internally protected by a dedicated 5 Amp rated fuse to prevent fault currents from damaging the entire backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat factors should I evaluate when replacing older GE Fanuc 90-30 modules with RX3i hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that your local rack backplane supports RX3i high-density modules and ensure your field wiring matches the isolated 4-point grouping schema.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014004302006,"sku":"IC694MDL330","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC694MDL634_c89e88e9-e43b-4e1c-90c1-fa93be9adfb0.jpg?v=1787815622","url":"https:\/\/www.plcsparehub.com\/products\/ic694mdl330-ge-fanuc-rx3i-ac-output-module-shop-now","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}