{"product_id":"ic694mdl310-ge-fanuc-pacsystems-rx3i-120vac-output-module-in-stock","title":"IC694MDL310 GE Fanuc PACSystems RX3i 120VAC Output Module In Stock","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-density load switching within the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003ePACSystems RX3i\u003c\/span\u003e\u003c\/b\u003e architecture, the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/span\u003e\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC694MDL310\u003c\/span\u003e\u003c\/b\u003e is a 120 VAC discrete output module. It packs 12 independently snubber-protected solid-state outputs split into two electrically isolated groups. Designed specifically for severe industrial environments, it directly controls high-inrush inductive actuators, field motor starters, and heavy-duty indicator banks without requiring external suppression arrays.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eKey Structural Features \u0026amp; Performance Highlights\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIsolated Dual-Group Topology:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eDivided into 2 distinct output banks containing 6 points per isolated group.\u003c\/li\u003e\n\u003cli\u003ePermits seamless operation across distinct AC line supply phases or independent circuit breakers.\u003c\/li\u003e\n\u003cli\u003eGuarded by a dedicated 3-Amp primary fuse assigned to each 6-point output group.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHeavy Inductive Load Management:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eEvery output point incorporates an onboard RC snubber for continuous voltage transient suppression.\u003c\/li\u003e\n\u003cli\u003eHandles peak surge inrush currents up to 5 Amps for one complete line cycle (10x continuous rating).\u003c\/li\u003e\n\u003cli\u003eDelivers clean, reliable switching for AC solenoids, magnetic contactors, and incandescent lamps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMechanical Interface \u0026amp; High-Voltage Identification:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures vivid red visual faceplate bands designating high-voltage AC field potential.\u003c\/li\u003e\n\u003cli\u003eUniversal rack slot placement allows installation into any open \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003ePACSystems RX3i\u003c\/span\u003e\u003c\/b\u003e I\/O slot.\u003c\/li\u003e\n\u003cli\u003eSupports standard box, extended box, spring, and extended spring terminal block connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications Parameter Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eBrand \/ Manufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/span\u003e\u003c\/b\u003e (Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003ePart \/ Model Number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC694MDL310\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eProduct Line Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003ePACSystems RX3i\u003c\/span\u003e\u003c\/b\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eModule Hardware Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eChannel Point Density\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e12 channels (2 isolated groups of 6 points each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eNominal Operating Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e120 Volts AC (50\/60 Hz nominal line frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003ePermissible Voltage Window\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 132 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eContinuous Output Rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 Amps maximum per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eMax Surge Inrush Capacity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Amps maximum for one full AC cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eSystem Bus Consumption\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mA from the backplane 5 VDC rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eCircuit Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Amp fuse per 6-point group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #f2f2f2;\"\u003e\u003cb\u003eNoise Suppression\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividual channel RC snubber network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eTarget Deployment \u0026amp; Application Environments\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHost System Compatibility:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003ePlugs directly into IC695CHS007, IC695CHS012, or IC695CHS016 \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003ePACSystems RX3i\u003c\/span\u003e\u003c\/b\u003e backplanes.\u003c\/li\u003e\n\u003cli\u003eOperates smoothly under central processing units such as IC695CPE305, IC695CPE310, and IC695CPE330.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndustrial Use Cases:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated switching of 120 VAC fluid control solenoid valves in water treatment plants.\u003c\/li\u003e\n\u003cli\u003eDirect coil activation for NEMA size 1-3 heavy motor starters and contactors.\u003c\/li\u003e\n\u003cli\u003eDriving 120 VAC cabinet alarm strobes, visual stack lights, and acoustic annunciators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Feedback \u0026amp; Visual Status Indicators\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eLogic Status Verification:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eFront-panel numbered green LEDs mirror real-time ON\/OFF CPU output command states.\u003c\/li\u003e\n\u003cli\u003eEnables immediate field confirmation of output logic states during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHardware Fault Detection:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eActive red alarm LEDs light up immediately when an output protection fuse clears.\u003c\/li\u003e\n\u003cli\u003eAccelerates troubleshooting by highlighting line-side electrical shorts or current overloads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSupply Chain \u0026amp; Warranty Guarantees\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBox Contents:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eOne factory-packaged \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/span\u003e\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC694MDL310\u003c\/span\u003e\u003c\/b\u003e AC output card.\u003c\/li\u003e\n\u003cli\u003eShielded antistatic enclosure surrounded by custom shock-mitigating foam.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty Policy:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes a comprehensive 12-month operational warranty from date of dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExpress Dispatch Logistics:\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eDispatched within 24 to 48 hours after payment processing.\u003c\/li\u003e\n\u003cli\u003eFast global air shipping handled via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen engineering or replacing an \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC694MDL310\u003c\/span\u003e\u003c\/b\u003e card, site technicians must remember that solid-state AC output switches depend on the natural zero-crossing behavior of alternating current to turn off. Attempting to switch direct current loads through this module will cause the solid-state switch to remain latched permanently ON once triggered, resulting in severe equipment field control loss.\u003c\/p\u003e\n\u003cp\u003eDuring a recent emergency service call at an industrial processing facility, our engineers identified a latched output channel on a \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC694MDL310\u003c\/span\u003e\u003c\/b\u003e module. Investigation revealed that an unsuppressed high-inductance relay coil was generating massive back-EMF, breaking down the internal RC snubber network over time. Installing an auxiliary isolation relay effectively suppressed the inductive feedback, restoring normal control loop operation. We strongly recommend auditing total field current draw against the 3-Amp group fuse threshold during routine maintenance to prevent unexpected blown-fuse downtime.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: Is it possible to switch 24 VDC control circuits using the IC694MDL310?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC694MDL310\u003c\/span\u003e\u003c\/b\u003e is strictly designed for 120 VAC power and cannot turn off when switching DC current loads.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What causes an output channel LED to glow red on the module faceplate?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: A red LED indicates that the 3-Amp inline protection fuse assigned to that 6-point output group has blown due to a circuit short or current surge.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Which field wiring terminal block should I choose for high-voltage AC field runs?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Extended depth terminal options, such as extended box or extended spring styles, provide the required wire bending radius and enclosure clearance for 120 VAC field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can the two isolated groups on the IC694MDL310 be fed from two separate AC line phases?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Group 1 and Group 2 are electrically isolated, allowing them to draw power from separate AC phases or individual feed breakers.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How can I confirm if a non-responsive field device is due to a blown group fuse or a damaged channel on the IC694MDL310?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check voltage from the terminal to neutral. If the green channel LED lights up but terminal voltage stays at zero while the red fuse LED remains off, isolate power and test the continuity of the 3-Amp fuse directly with a multimeter.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014004269238,"sku":"IC694MDL310","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC694MDL310.jpg?v=1788333123","url":"https:\/\/www.plcsparehub.com\/products\/ic694mdl310-ge-fanuc-pacsystems-rx3i-120vac-output-module-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}