{"product_id":"ic694mdl250-ge-fanuc-rx3i-16-point-discrete-input-module-120v","title":"IC694MDL250 GE Fanuc RX3i 16-Point Discrete Input Module - 120V","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e is a high-performance 120 VAC discrete input module engineered specifically for the PACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e and Series 90-30 controller environments. Originally manufactured by GE Intelligent Platforms and presently supported through Emerson Automation, this robust input card features sixteen (16) individually isolated channels designed to handle high-voltage industrial signaling safely. Industrial automation professionals rely on the \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e to capture binary inputs from complex field devices while ensuring reliable galvanic isolation and noise immunity in harsh operating conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc \/ GE Intelligent Platforms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-rx3i-rx7i-pacsystem\"\u003ePACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 16-Channel Discrete Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e 120 VAC (47 to 63 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 0 to 132 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 16 individually isolated points in a single group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Range:\u003c\/strong\u003e 70 VAC to 132 VAC (6 mA current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage Range:\u003c\/strong\u003e 0 VAC to 20 VAC (2.5 mA current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current Draw:\u003c\/strong\u003e 14.5 mA nominal per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Consumption:\u003c\/strong\u003e 60 mA at 5 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Maximum 30 ms (On-state), Maximum 45 ms (Off-state)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Isolation:\u003c\/strong\u003e 250 VAC continuous; 1500 VAC for 1 minute channel-to-backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Terminal Connectors:\u003c\/strong\u003e IC694TBBx32 or IC694TBSx32 block kits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Environment:\u003c\/strong\u003e Class 1, Division 2, Groups A, B, C, D hazardous areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Integration Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Flexibility:\u003c\/strong\u003e Can be installed on standard DIN rails or directly onto panel mounting bases within local racks or distributed I\/O drop nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e Supports hot-swappable replacement procedures, allowing technicians to swap modules safely without powering down the entire backplane rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Prerequisite:\u003c\/strong\u003e Requires host CPU firmware version 3.5 or later to properly parse high-speed data exchanges and terminal diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Specifications:\u003c\/strong\u003e Terminate field signals using appropriate cable gauges into compatible terminal blocks equipped with built-in RC snubbers for transient noise suppression.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning \u0026amp; Maintenance Ease\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Status Indicators:\u003c\/strong\u003e Each of the 16 input points features a dedicated front-panel LED that illuminates to provide instant visual feedback on signal status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Filtering:\u003c\/strong\u003e Software-selectable input filter times ranging from 20 ms to 2,540 ms (in 20 ms increments) can be pushed directly from the CPU to eliminate line chatter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Diagnostics:\u003c\/strong\u003e Field-side terminal block errors and open-wire conditions are automatically reported back to the main RX3i central processor for rapid troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility \u0026amp; Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Compatibility:\u003c\/strong\u003e Fully compatible with PACSystems \u003cstrong\u003eRX3i\u003c\/strong\u003e racks, expansion bases, and high-speed serial backplane communication architectures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Standards:\u003c\/strong\u003e Certified to UL 508 and equivalent to CSA C22.2 No. 142-M1987 standards for industrial control equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Approval:\u003c\/strong\u003e Approved for safe deployment in Class 1, Division 2 hazardous industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePacking List \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacking List:\u003c\/strong\u003e One (1) \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e Discrete Input Module, protective anti-static packaging casing, and hardware documentation sheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Fully backed by a comprehensive 12-month warranty covering structural integrity and operational performance from the date of purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier Network:\u003c\/strong\u003e Express global shipping handled securely through trusted carriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Window:\u003c\/strong\u003e Orders are verified, securely packed, and dispatched within 24-48 hours to minimize unexpected plant downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Application Scenes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing Assembly Lines:\u003c\/strong\u003e Monitoring status signals from push-button control desks, limit switches, and mechanical auxiliary contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy Processing Plants:\u003c\/strong\u003e Interfacing with high-voltage proximity sensors and thumbwheel selectors in rugged chemical or metal processing floors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Skids:\u003c\/strong\u003e Capturing binary feedback states from industrial switchgear and relay protection panels operating on 120V AC utility lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eWhen deploying high-voltage AC input cards like the \u003cstrong\u003eIC694MDL250\u003c\/strong\u003e in heavy industrial zones, induced electrical noise from nearby variable frequency drives can sometimes cause phantom state toggling. Based on field installation experience, our engineering team strongly recommends utilizing shielded control cables, ensuring proper cabinet earth grounding, and configuring appropriate input filter times (e.g., setting filters above 40 ms) in the programming software to completely filter out high-frequency transient spikes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary advantage of the individual channel isolation on the IC694MDL250?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIndividual channel isolation ensures that an electrical fault or overvoltage condition on one input point will not propagate or damage adjacent channels or internal backplane circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC694MDL250 module be replaced while the system is powered on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module supports hot-swapping within compatible RX3i backplane architectures, permitting replacement without shutting down the entire control rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure input filter times for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInput filter times are configured within the programming software configuration tree and sent directly from the RX3i CPU to the module in 20 ms increments up to 2,540 ms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field wiring accessories are required for proper connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module relies on compatible terminal block options such as the IC694TBBx32 or IC694TBSx32 snap-in connector assemblies for secure field wiring terminations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat buying criteria should I consider when selecting replacement input modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways verify your rack's available backplane slot capacity, check that your CPU firmware version meets the 3.5 minimum requirement, and match the nominal field voltage (120 VAC) to your existing sensor infrastructure.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014004203702,"sku":"IC694MDL250","price":114.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC694MDL250.jpg?v=1786513495","url":"https:\/\/www.plcsparehub.com\/products\/ic694mdl250-ge-fanuc-rx3i-16-point-discrete-input-module-120v","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}