{"product_id":"ic693pwr330-ge-fanuc-series-90-30-plc-power-supply-30w","title":"IC693PWR330 GE Fanuc Series 90-30 PLC Power Supply | 30W","description":"\u003ch3\u003e\u003cb\u003eIC693PWR330 | High-Capacity Power for Series 90-30 Racks\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eGE Fanuc IC693PWR330\u003c\/b\u003e is a high-capacity power supply for the \u003cb\u003eSeries 90-30 PLC\u003c\/b\u003e platform. It converts a compatible AC or DC input into the DC rails used by the PLC backplane and supported field circuits.\u003c\/p\u003e\n\u003cp\u003eIts principal selection advantage is the stated 30W capacity on the 5VDC rail, making it relevant to Series 90-30 racks with substantial 5V backplane demand. Before installation, engineers should calculate the actual load on each output and confirm the power supply’s combined-load limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePower-Rail Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e5VDC backplane supply:\u003c\/b\u003e powers the PLC backplane and connected modules. The supplied data lists up to 30W for this rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e24VDC relay supply:\u003c\/b\u003e provides power for supported Series 90-30 relay-output circuitry; the supplied rating is up to 15W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIsolated 24VDC output:\u003c\/b\u003e provides an isolated supply for compatible modules and, where permitted by the system design, external 24VDC input circuits. The supplied rating is up to 20W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAC\/DC input flexibility:\u003c\/b\u003e accepts a specified AC input range or DC input range, subject to correct wiring and polarity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 99.9421%; height: 529.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eManufacturer \/ Brand\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eCatalog Number\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e\u003cb\u003eIC693PWR330\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003ePLC Family\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-series-90-30-series-90-70\"\u003eSeries 90-30\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003eHigh-capacity PLC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eNominal Input\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e120\/240V AC or 125V DC, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eAC Input Range\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e85–264V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eDC Input Range\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e100–300V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eInput Power\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e90VA with AC input; 50W with DC input, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eInrush Current\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e4A peak; 250ms maximum, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003e5VDC Output\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e5.0–5.2V DC; 5.1V nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003e5VDC Output Power\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003eUp to 30W, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003e24VDC Relay Output\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e24–28V DC; up to 15W, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 39.2px;\"\u003eIsolated 24VDC Output\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 39.2px;\"\u003e21.5–28V DC; up to 20W, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eHoldup Time\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003e20ms minimum, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 39.2px;\"\u003e5VDC Overvoltage Protection\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 39.2px;\"\u003e6.4–7V, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 39.2px;\"\u003e5VDC Overcurrent Protection\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 39.2px;\"\u003e7A, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 39.2px;\"\u003eUser Connection Terminals\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 39.2px;\"\u003e6, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 39.2px;\"\u003eSerial Interface\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 39.2px;\"\u003eRS-485 port listed in the supplied description; verify supported functions and connection details in the product manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eInstallation Position\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003eLeftmost slot of a compatible Series 90-30 rack, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 19.6px;\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 19.6px;\"\u003eUL and CE, as supplied; verify markings on the specific unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 22.0507%; height: 39.2px;\"\u003eLifecycle Note\u003c\/th\u003e\n\u003ctd style=\"width: 76.0362%; height: 39.2px;\"\u003eReported as discontinued\/obsolete in the supplied data; confirm current sourcing status and product condition before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ci\u003ePower-rating clarification: The supplied material lists 30W for the 5VDC output, 20W for isolated 24VDC, and 15W for the 24VDC relay output, while also describing a 30W overall capacity. These figures should not be interpreted as simultaneously available output power. Confirm the manufacturer’s load-sharing and combined-output limits using the applicable IC693PWR330 manual and rack power calculation.\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eRack Placement and Electrical Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC693PWR330 is installed in the designated power-supply position at the left side of a compatible Series 90-30 rack. It supplies the backplane rails required by the CPU and installed I\/O or specialty modules. It is not an independent field I\/O device.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eRack load calculation:\u003c\/b\u003e total the 5VDC demand of the installed modules and check any 24VDC loads against the relevant output ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput source selection:\u003c\/b\u003e verify whether the panel provides AC or DC power and that it falls within the applicable input range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDC polarity:\u003c\/b\u003e follow the terminal diagram carefully; the supplied description states that DC input connections are polarity-sensitive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProtective earth:\u003c\/b\u003e connect grounding and protective conductors according to the equipment manual and site electrical standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTerminal work:\u003c\/b\u003e isolate and verify input power before wiring, removal, or replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eEquipment and Application Suitability\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eGE Fanuc Series 90-30 PLC racks:\u003c\/b\u003e supplies backplane power to compatible CPU, digital I\/O, analog I\/O, and specialty modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHigh 5V backplane-load configurations:\u003c\/b\u003e may be appropriate where the installed rack requires the high-capacity 5V rail, provided the rack’s calculated demand is within the documented limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLegacy machine-control panels:\u003c\/b\u003e supports continued operation of existing Series 90-30 control equipment when the power-supply type and rack configuration match.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProcess and utility control cabinets:\u003c\/b\u003e provides PLC power for compatible control applications; suitability depends on module load, environmental conditions, and panel design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaintenance and replacement:\u003c\/b\u003e can serve as a matching spare for a documented installation, subject to verification of the exact part number and condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eSelection boundary:\u003c\/b\u003e Do not choose this module solely because the input voltage matches. Confirm rack compatibility, the required 5V current, the use of the 24V outputs, and the combined power budget.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCommissioning Checks\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cb\u003eIdentify the rack:\u003c\/b\u003e record the Series 90-30 rack configuration and the catalog numbers of the CPU and installed modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCalculate rail demand:\u003c\/b\u003e use module-specific power consumption data to calculate the 5VDC load and any applicable 24VDC loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCheck source voltage:\u003c\/b\u003e measure the incoming AC or DC supply and confirm it is within the rated input range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInspect wiring and terminals:\u003c\/b\u003e check polarity for DC input, terminal tightness, protective earth, and signs of heat damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVerify output rails:\u003c\/b\u003e after installation and safe energization, measure the relevant DC rails and check that they remain within specification under normal rack load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConfirm system operation:\u003c\/b\u003e review CPU and module status after power-up and investigate any rack faults before returning equipment to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Guide: Power Supply or Rack-Level Fault?\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eA power-related PLC fault may originate in the incoming supply, the power supply module, an overloaded rail, a wiring issue, or a downstream module. Use measurements and system diagnostics to narrow the cause.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNo power or failed startup:\u003c\/b\u003e verify the incoming source, terminal connections, and correct AC\/DC input configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCPU or I\/O modules report faults:\u003c\/b\u003e check the backplane voltage and determine whether the installed rack load exceeds the supply’s capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIntermittent resets:\u003c\/b\u003e investigate input dips, loose connections, excessive load, and whether the minimum holdup requirement is being met under actual conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAbnormal 24V behavior:\u003c\/b\u003e identify whether the affected circuit uses the relay supply or isolated 24V output, then check its load and wiring against the correct output rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStatus indicators:\u003c\/b\u003e observe the power supply’s available LEDs and record their state. The supplied description mentions PWR and OK indicators, as well as RUN and BATT indications; verify the exact indicator meanings for the installed unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSuspected overload:\u003c\/b\u003e compare the measured load with the manufacturer’s rail and combined-output limits. Do not repeatedly reset or re-energize a suspected overload without identifying its cause.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe listed RS-485 interface should not be assumed to provide general-purpose PLC communications or a specific diagnostic protocol without confirmation from the applicable manual.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB’s Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eFor the IC693PWR330, a reliable replacement decision starts with the rack’s power budget. Engineers should calculate the 5V backplane demand from the installed modules and separately account for relay and isolated 24V usage. The output ratings in product summaries can be misread as independent, simultaneous power allowances; check the manufacturer’s combined-load specifications before commissioning.\u003c\/p\u003e\n\u003cp\u003eBecause the supplied lifecycle information identifies this model as discontinued or obsolete, verify the exact catalog number, physical condition, and sourcing details before placing an order. For an operating legacy rack, document the existing supply wiring and measure the rail behavior under load before concluding that the supply itself is defective.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eWarranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12 months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping carriers:\u003c\/b\u003e FedEx, UPS, and DHL, subject to destination and shipping arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQuotation details:\u003c\/b\u003e provide catalog number \u003cb\u003eIC693PWR330\u003c\/b\u003e, quantity, destination, rack or CPU details, and any required condition or packaging information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e1. How do I determine whether the IC693PWR330 has enough capacity for my rack?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eList every installed module and obtain its specified 5VDC and applicable 24VDC consumption. Add the loads by rail and compare them with the power supply’s documented limits, including combined-output restrictions. Leave appropriate design margin rather than sizing only to the nominal wattage.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e2. Can I replace another Series 90-30 power supply with this high-capacity model?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. Compare the replacement’s catalog number, input range, rack position, output rails, and power ratings with the original supply and the rack’s requirements. A higher 5V capacity does not establish compatibility with every rack or load arrangement.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e3. What should I inspect if the PLC resets when additional I\/O modules are installed?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eRecalculate the rack’s power demand and measure the 5V rail under load. Check for an overloaded supply, loose backplane or power connections, input-voltage sag, and a faulty module drawing abnormal current. Add modules only after verifying the power budget.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e4. Does the RS-485 port mean the power supply can be used as a general communications adapter?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNo such capability should be assumed from the port description alone. Confirm the interface’s intended function, supported device connections, and protocol in the relevant GE Fanuc documentation before designing a communications or diagnostic connection.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e5. What information is most useful when sourcing this legacy power supply?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eProvide a clear image of the nameplate, the exact catalog number, the rack and CPU model, the input source type, and the measured or calculated rail loads. Also confirm whether the replacement must match a particular product condition or certification marking, since the supplied lifecycle data identifies the part as obsolete.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013993849014,"sku":"IC693PWR330","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC693PWR330-3.jpg?v=1792479878","url":"https:\/\/www.plcsparehub.com\/products\/ic693pwr330-ge-fanuc-series-90-30-plc-power-supply-30w","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}