{"product_id":"ic693mdl940-series-90-30-relay-output-module-ge-fanuc","title":"IC693MDL940 Series 90-30 Relay Output Module GE Fanuc","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL940\u003c\/strong\u003e is a high-density 16-point relay output module designed for the \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/strong\u003e (Emerson Automation) \u003cstrong style=\"color: #0056b3;\"\u003eSeries 90-30\u003c\/strong\u003e programmable logic controller family. Built to interface high-power field actuators directly with low-voltage PLC logic, this discrete output card delivers dry-contact switching versatility across both AC and DC load circuits.\u003c\/p\u003e\n\u003cp\u003eOrganized into 4 isolated output groups with 4 relay channels per group, the \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL940\u003c\/strong\u003e accommodates operating voltages from 5 to 30V DC and 5 to 250V AC (50\/60 Hz). Each contact rating supports up to 2.0 Amperes resistive load per point (4.0 Amperes max per common line), offering robust isolation between field voltage variations and internal backplane logic.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe operational and mechanical metrics below are categorized using MECE principles to facilitate straightforward engineering review.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \/ Manufacturer:\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eGE Fanuc\u003c\/strong\u003e (Legacy) \/ Emerson Automation (Current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL940\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-series-90-30-series-90-70\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003eSeries 90-30\u003c\/strong\u003e\u003c\/a\u003e PLC System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e Discrete Relay Output Module (NO Contacts)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Output Channels:\u003c\/strong\u003e 16 Points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Configuration:\u003c\/strong\u003e 4 Isolated Groups (4 Output Contacts per Common)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage Rating:\u003c\/strong\u003e 24V DC \/ 120\/240V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Operating Range:\u003c\/strong\u003e 5 to 30V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Operating Range:\u003c\/strong\u003e 5 to 250V AC (50\/60 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Current per Point:\u003c\/strong\u003e 2.0 Amperes resistive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Current per Common:\u003c\/strong\u003e 4.0 Amperes total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Load Current:\u003c\/strong\u003e 10 mA (required for reliable contact cleaning action)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inrush Surge Current:\u003c\/strong\u003e 5.0 Amperes peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Response Time:\u003c\/strong\u003e 15 ms maximum (both On delay and Off delay)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Protection:\u003c\/strong\u003e Group-to-group and channel-to-backplane optical isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e Individual LED indicators per output channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Slot Location:\u003c\/strong\u003e Occupies 1 slot in any standard 5-slot or 10-slot baseplate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWiring \u0026amp; Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAdhering to correct field wiring practices prevents premature mechanical contact wear and backplane signal corruption.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTurn off system supply power before seating or extracting the \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL940\u003c\/strong\u003e card from the chassis.\u003c\/li\u003e\n\u003cli\u003eAlign the circuit board module with guide slots and firmly press until top and bottom latches click into place.\u003c\/li\u003e\n\u003cli\u003eGroup field power feeds according to circuit requirements, taking care not to exceed 4.0 Amperes per common terminal.\u003c\/li\u003e\n\u003cli\u003eConnect inductive AC or DC loads using RC snubbers or flyback suppressors wired directly across load terminals.\u003c\/li\u003e\n\u003cli\u003eEnsure field wiring gauge matches terminal block screw specs, stripping insulation cleanly without nicking conductors.\u003c\/li\u003e\n\u003cli\u003eVerify that the total load current on any single contact remains at or above 10 mA to guarantee proper contact wipe.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eField Diagnostics \u0026amp; Protection Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL940\u003c\/strong\u003e features optical isolation barriers that separate high-voltage field wiring from backplane microprocessors.\u003c\/p\u003e\n\u003cp\u003eFront-panel LED status indicators display real-time logic states for all 16 channels, making visual verification straightforward during commissioning. Mechanical relay contacts absorb transient inrush spikes up to 5.0 Amperes, while individual group commons isolate distinct voltage sources across the same module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Field Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eControls engineers specify the \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL940\u003c\/strong\u003e across industrial plants requiring flexible switching of mixed-voltage devices.\u003c\/p\u003e\n\u003cp\u003eTypical target equipment includes solenoid valves, motor starter contactor coils, alarm annunciation horns, interposing relay banks, and indicator lights. Its dual AC\/DC capability makes it well-suited for water processing, material handling conveyors, HVAC plant management, and automated packaging lines.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur control specialists frequently audit legacy \u003cstrong style=\"color: #0056b3;\"\u003eSeries 90-30\u003c\/strong\u003e hardware in high-duty industrial environments. The \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL940\u003c\/strong\u003e offers remarkable flexibility, but contact longevity depends heavily on suppressing inductive inductive kickback.\u003c\/p\u003e\n\u003cp\u003eIn a recent field call at a wastewater pumping station, an engineering team reported premature contact welding on channels controlling 120V AC solenoid valves. The inductive voltage spikes during de-energization were causing contact arcing. Fitting metal-oxide varistors (MOVs) across the AC valve coils suppressed inductive flyback voltage and eliminated relay contact pitting. We strongly advise placing RC snubbers across AC inductive loads and flyback diodes across DC loads to maximize contact service life.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Selection \u0026amp; Integration Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMatching output module specifications to actuator electrical characteristics prevents system downtime during operation.\u003c\/p\u003e\n\u003cp\u003eSelect the \u003cstrong style=\"color: #0056b3;\"\u003eIC693MDL940\u003c\/strong\u003e when controlling loads that operate across different voltage levels or require dry-contact relay action. If your system requires high-speed electronic switching without mechanical wear, evaluate solid-state transistor cards like the IC693MDL740 instead. Always verify that total continuous current drawn through each common terminal does not exceed 4.0 Amperes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDelivery Terms \u0026amp; 12-Month Hardware Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvery module is sealed inside antistatic protective packaging and shipped in heavy-duty cartons lined with custom foam padding.\u003c\/p\u003e\n\u003cp\u003eWe back each unit with a complete 12-month hardware replacement warranty covering contact execution and component reliability. Orders process rapidly with dispatch within 24 to 48 hours via leading international couriers including FedEx, UPS, or DHL.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan individual channels on the IC693MDL940 switch different voltage levels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, because the module is divided into 4 separate isolated groups, each group can operate on a distinct AC or DC voltage supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum response time for contact switching?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBoth the turn-on delay and turn-off delay times are rated at a maximum of 15 milliseconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is there a minimum load current rating of 10 mA per point?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA minimum current flow of 10 mA ensures sufficient electrical energy to clean oxidation off internal mechanical relay contacts during switching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a field load draws more than 4 Amperes through a single common terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExceeding 4 Amperes per common can cause thermal overheating of internal board traces, leading to trace failure or module damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat express shipping carriers are used to deliver emergency orders?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOrders process rapidly and ship within 24 to 48 hours using global express carriers such as FedEx, UPS, or DHL.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014003122358,"sku":"IC693MDL940","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC693MDL940.jpg?v=1784706705","url":"https:\/\/www.plcsparehub.com\/products\/ic693mdl940-series-90-30-relay-output-module-ge-fanuc","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}