{"product_id":"ic693mdl241-ge-fanuc-series-90-30-input-module-in-stock","title":"IC693MDL241 GE Fanuc Series 90-30 Input Module In Stock","description":"\u003ch3\u003eExecutive Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693MDL241\u003c\/strong\u003e\u003c\/span\u003e is a 16-channel discrete input module engineered for the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc \/ Emerson Series 90-30\u003c\/strong\u003e\u003c\/span\u003e PLC platform. Designed with flexibility in mind, it supports 24 VAC and 24 VDC input signals across a single isolated group of 16 points. In DC mode, it accommodates both sink (positive) and source (negative) wiring configurations, bridging diverse field instruments directly to the backplane logic.\u003c\/p\u003e\n\u003cp\u003eAccepting input voltages up to 30 VAC\/VDC, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693MDL241\u003c\/strong\u003e\u003c\/span\u003e converts field digital states into %I memory bits, providing isolation up to 1500 V RMS between field wiring and internal backplane logic.\u003c\/p\u003e\n\u003ch3\u003eCore Architecture \u0026amp; Field Wiring Layout\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693MDL241\u003c\/strong\u003e\u003c\/span\u003e features a single-group architecture where all 16 input channels share a common return terminal. Field devices can be energized using user-supplied external power or the isolated 24 VDC power supply provided by the Series 90-30 baseplate.\u003c\/p\u003e\n\u003cp\u003eTwo horizontal rows of 8 green LEDs (labeled A1–A8 for channels 1–8 and B1–B8 for channels 9–16) display real-time optical indication of channel energization. A removable faceplate insert allows custom wire tagging for easy maintenance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6; width: 30%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc \/ Emerson Automation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-series-90-30-series-90-70\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSeries 90-30\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693MDL241\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e24 VAC \/ VDC Discrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e16 Channels (Single Group, Common Return)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eWiring Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003ePositive \/ Negative Logic (Sinking or Sourcing in DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e24 VAC \/ 24 VDC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eOperating Input Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e0 to 30 VAC \/ 0 to +30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eOn-State Voltage \u0026amp; Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e11.5 to 30.0 VAC\/VDC | Min 3.2 mA (7 mA typical at rated voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eOff-State Voltage \u0026amp; Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e0 to 4.0 VAC\/VDC | Max 1.0 mA leakage current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eSignal Filter Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eOn delay: 12 ms max | Off delay: 28 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eField-to-Logic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e1500 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e80 mA @ 5 VDC backplane | 125 mA from isolated 24 VDC bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eMemory Addressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e%I discrete register locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Requirements \u0026amp; Rack Installation Rules\u003c\/h3\u003e\n\u003cp\u003eTo integrate the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693MDL241\u003c\/strong\u003e\u003c\/span\u003e correctly into a Series 90-30 chassis, ensure compliance with these rules:\u003c\/p\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBackplane \u0026amp; Power Requirements\u003c\/strong\u003e\n\u003cul style=\"list-style-type: square; margin-top: 4px; padding-left: 25px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Compatibility:\u003c\/strong\u003e Installs into any standard input\/output slot of a 5-slot or 10-slot Series 90-30 baseplate (IC693CHS391, IC693CHS397, etc.).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Budget Allocation:\u003c\/strong\u003e Ensure the power supply (such as IC693PWR321) has at least 80 mA available on the 5 VDC bus and 125 mA available on the isolated 24 VDC rail when all 16 inputs are active.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Sourcing:\u003c\/strong\u003e DC input loops can utilize the baseplate isolated 24 VDC supply or an external regulated power source. AC loops require an external AC line supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Equipment, Applications \u0026amp; Diagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693MDL241\u003c\/strong\u003e\u003c\/span\u003e connects binary field sensors to the controller core across mixed AC\/DC electrical environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Machinery \u0026amp; Application Scenarios:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial conveyor lines incorporating 24 VDC proximity switches and photoelectric eye sensors.\u003c\/li\u003e\n\u003cli\u003eLegacy motor control centers (MCC) utilizing 24 VAC auxiliary relay contacts for run\/trip status feedback.\u003c\/li\u003e\n\u003cli\u003ePneumatic actuator positioning systems monitored by dry mechanical limit switches and pressure switches.\u003c\/li\u003e\n\u003cli\u003eOperator control stations equipped with illuminated pushbuttons and selector switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Visual LED Indication:\u003c\/strong\u003e Optical status block allows technicians to instantly verify whether voltage is present across individual channel circuits without multimeter probing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Threshold Detection:\u003c\/strong\u003e Channels enforce a strict 11.5 V threshold for logic 1 and 4.0 V for logic 0, filtering out induced field cable noise and floating voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware State Mapping:\u003c\/strong\u003e Module status updates %I bit addresses continuously during backplane scan sweeps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eKeep these engineering factors in mind during installation or troubleshooting:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Mixed Voltage Isolation Strategy:\u003c\/strong\u003e Because all 16 input points share a single common return terminal, you cannot mix 24 VAC and 24 VDC on the same module. The entire 16-point bank must run on a unified power reference. If your panel design requires mixed AC and DC signals, separate them across dedicated input cards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Contact Leakage \u0026amp; Off-State Thresholds:\u003c\/strong\u003e Solid-state field sensors (such as 2-wire proximity sensors) often exhibit off-state leakage current. Ensure leakage remains well below 1.0 mA and off-state voltage drops below 4.0 V to prevent the card from registering false logic 1 state triggers.\u003c\/p\u003e\n\u003ch3\u003eLogistics, Packaging \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Protection:\u003c\/strong\u003e Covered by a comprehensive \u003cstrong\u003e12 Months Warranty\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Order Fulfillment:\u003c\/strong\u003e Ships from stock within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Courier Delivery:\u003c\/strong\u003e Worldwide air shipping via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, or \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Packaging:\u003c\/strong\u003e Enclosed in anti-static ESD bags with protective foam within reinforced export packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guide \u0026amp; Technical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Guide: How do I choose between internal backplane power and external power for DC field sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the isolated 24 VDC supply from the baseplate terminal block for simple panel pushbuttons or mechanical switches. For long field cable runs exposed to high electrical noise, use an external power supply to protect the backplane from ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy are the LED status lights unlit even though 24V is present across the sensor wires?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that the field ground or neutral line is connected to the common terminal. An open common line breaks the current loop, keeping input current below the 3.2 mA threshold required to turn on the optical coupler and status LED.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does signal transition delay affect fast-moving counting applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe card features an on delay of 12 ms and an off delay of 28 ms designed for contact bounce suppression. For high-speed pulse counting above 20 Hz, high-speed counter cards (like IC693APU300) should be specified instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I wire a PNP (sourcing) proximity sensor to this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Connect the positive terminal of your DC power supply to the proximity sensor, connect the sensor output signal to the desired card terminal, and wire the negative supply rail to the card common terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat checks should be performed before replacing an existing MDL241 card under live power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower off field wiring before removing the terminal block from the front connector. While Series 90-30 baseplates are sturdy, pulling field wiring under load on vintage hardware risks arc arcing or shorting adjacent pins.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014002565302,"sku":"IC693MDL241","price":116.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC693MDL241.jpg?v=1788163425","url":"https:\/\/www.plcsparehub.com\/products\/ic693mdl241-ge-fanuc-series-90-30-input-module-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}