{"product_id":"ic693cpu372-single-slot-modular-cpu-133mhz-ge-fanuc-series-90-30","title":"IC693CPU372 Single-Slot Modular CPU 133MHz GE Fanuc Series 90-30","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693CPU372\u003c\/strong\u003e\u003c\/span\u003e is a high-performance single-slot central processing unit engineered for the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSeries 90-30\u003c\/strong\u003e\u003c\/span\u003e modular PLC platform by \u003cstrong\u003eGE Fanuc\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDriven by an AMD SC520 processor running at 133 MHz clock speed, this 32-bit module executes complex Boolean operations in just 0.15 milliseconds per 1K logic block.\u003c\/p\u003e\n\u003cp\u003eThe controller integrates dual auto-sensing 10\/100 Mbps RJ-45 Ethernet interfaces that function as an internal switch, enabling linear daisy-chain and Device Level Ring (DLR) network topologies without requiring external network switches.\u003c\/p\u003e\n\u003cp\u003eIt supports up to 240 Kbytes of user program memory with battery-backed RAM or non-volatile Flash storage options, making the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693CPU372\u003c\/strong\u003e\u003c\/span\u003e ideal for large-scale industrial control architectures.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003e\u003cstrong\u003eSpecification Parameter\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth\u003e\u003cstrong\u003eTechnical Value \/ Operational Capability\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBrand \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\n\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSeries 90-30\u003c\/strong\u003e\u003c\/span\u003e Architecture\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart \/ Model Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693CPU372\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProcessor Model \u0026amp; Architecture\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAMD SC520 \/ 80386EX Engine (32-bit System)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eClock Frequency \u0026amp; Execution Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e133 MHz Clock \/ 0.15 ms per 1K Boolean Logic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUser Program \u0026amp; Register Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e240 Kbytes (Battery-backed RAM \/ Optional Flash)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Capacity (%I \/ %Q)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2,048 Discrete Inputs \/ 2,048 Discrete Outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAnalog I\/O Capacity (%AI \/ %AQ)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 32,640 Analog Input Words \/ 32,640 Analog Output Words\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEmbedded Ethernet Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDual 10BaseT \/ 100BaseTX RJ-45 Auto-Sensing Ports\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eModbus TCP Server\/Client, EGD, SRTP, IEEE 802.3 TCP\/IP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Expansion Capability\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSupports up to 7 Expansion and 7 Remote Baseplates\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMath Processing Unit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHardware-based Floating-Point Co-Processor Built-in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.4 Watts at 5 Volts DC from Backplane Bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSystem Installation \u0026amp; Hardware Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693CPU372\u003c\/strong\u003e\u003c\/span\u003e in Slot 1 of any standard \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eSeries 90-30\u003c\/strong\u003e\u003c\/span\u003e baseplate, directly adjacent to the power supply unit.\u003c\/p\u003e\n\u003cp\u003eEnsure the rack bus backplane power is fully isolated prior to seating or unseating the module in the chassis.\u003c\/p\u003e\n\u003cp\u003eConnect Ethernet cabling using shielded CAT5e or CAT6 Twisted Pair wires to prevent electromagnetic noise coupling.\u003c\/p\u003e\n\u003cp\u003eMaintain proper battery backup connections to prevent total user memory loss during complete system power shutdowns.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePlatform Compatibility \u0026amp; Operational Protocols\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693CPU372\u003c\/strong\u003e\u003c\/span\u003e communicates smoothly with PACSystems equipment, VersaMax remote I\/O nodes, and legacy hardware.\u003c\/p\u003e\n\u003cp\u003eIntegrated software configurations run through Proficy Machine Edition Logic Developer PLC programming packages.\u003c\/p\u003e\n\u003cp\u003eSupports up to three joined Ethernet option modules within the local chassis to expand network gateway capabilities.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; System Surveillance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAn integrated web server allows field engineers to perform remote system diagnosis and network status monitoring using any standard browser.\u003c\/p\u003e\n\u003cp\u003eFront-panel LED status indicators provide immediate feedback for CPU operation, memory health, battery condition, and Ethernet link\/activity status.\u003c\/p\u003e\n\u003cp\u003eA dedicated Station Manager connector enables direct serial diagnostic tracing during deep protocol troubleshooting.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCommissioning, Maintenance \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eQuick configuration can be deployed using the built-in web management interface or Proficy software environments.\u003c\/p\u003e\n\u003cp\u003eDedicated hardware reset switches and main control switches streamline field commissioning and fault recovery workflows.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e1x Factory-Inspected \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc IC693CPU372\u003c\/strong\u003e\u003c\/span\u003e CPU Module\u003c\/li\u003e\n  \u003cli\u003e1x Backplane Bus Connector Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty \u0026amp; Dispatch Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Comprehensive 12-Month Operational Warranty included\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDispatch Timeframe:\u003c\/strong\u003e Ready for express dispatch within 24 to 48 hours\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLogistics Partners:\u003c\/strong\u003e Worldwide fast transport via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Practical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHigh-speed motion control and continuous loop regulation in automated material handling networks.\u003c\/p\u003e\n\n\u003cp\u003eReal-time data exchange across distributed pumping stations using Ethernet Global Data (EGD) messaging.\u003c\/p\u003e\n\n\u003cp\u003eProcess automation control systems in water treatment plants and power distribution substations.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eField installations reveal that network dropouts on the dual Ethernet ports are frequently tied to duplicate IP assignments across the local subnet.\u003c\/p\u003e\n\n\u003cp\u003eDuring a system overhaul at a metal processing plant, the CPU experienced intermittent SRTP communication timeouts during heavy data logging cycles.\u003c\/p\u003e\n\n\u003cp\u003eUsing the onboard Station Manager interface, field engineers diagnosed high network packet collisions caused by unmanaged switch loops in the cabinet network.\u003c\/p\u003e\n\n\u003cp\u003eImplementing a Device Level Ring (DLR) structure across the two auto-sensing ports of the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693CPU372\u003c\/strong\u003e\u003c\/span\u003e restored network stability completely, eliminating communication latencies.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSelection \u0026amp; Application Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSelect the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC693CPU372\u003c\/strong\u003e\u003c\/span\u003e if your legacy control architecture requires embedded dual Ethernet ports without relying on separate daughterboards.\u003c\/p\u003e\n\u003cp\u003eFor applications needing larger memory structures or higher processing speeds, consider upgrading to the PACSystems RX3i CPU platform.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion 1: How do I configure IP settings on the CPU module during initial commissioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Use Proficy Machine Edition or access the onboard web server via a direct Ethernet connection to set the static IP address.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion 2: What is the primary operational function of the dual Ethernet ports on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: They act as an embedded unmanaged switch with a single IP address, supporting daisy-chaining and ring network architectures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion 3: Will the module retain stored logic programs if the internal battery completely fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: RAM memory will clear, but program code remains permanently safe if backed up to an optional Flash non-volatile memory card.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion 4: Can the CPU interface directly with Modbus TCP field devices without third-party converters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Yes, the built-in firmware supports native Modbus TCP Server and Client protocols directly over the Ethernet interface.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestion 5: What causes the main STATUS LED to blink rapidly during bootup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: A rapid blinking red LED typically indicates a memory checksum fault, corrupt user logic, or an unassigned system IP configuration.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014002466998,"sku":"IC693CPU372","price":162.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC693CPU372.jpg?v=1785740474","url":"https:\/\/www.plcsparehub.com\/products\/ic693cpu372-single-slot-modular-cpu-133mhz-ge-fanuc-series-90-30","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}