{"product_id":"ic693cpu363-plc-processor-module-ge-fanuc-series-90-30-240kb-cpu","title":"IC693CPU363 PLC Processor Module GE Fanuc Series 90-30 240KB CPU","description":"\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eSystem Architecture \u0026amp; Processing Core\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eIC693CPU363\u003c\/span\u003e\u003c\/b\u003e operates as a high-speed, single-slot processor module within the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eGE Fanuc Series 90-30\u003c\/span\u003e\u003c\/b\u003e programmable logic controller platform. Driven by an 80386EX microprocessor running at 25 MHz, this central processing unit executes Boolean logic at a typical scan rate of 0.22 milliseconds per 1K instructions. Engineers deploy this controller to manage complex industrial automation routines, coordinate distributed I\/O networks across up to eight baseplates, and facilitate simultaneous data exchanges with HMI, SCADA, and host workstation systems.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eHardware \u0026amp; Memory Specification Matrix\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eManufacturer \u0026amp; Platform:\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eGE Fanuc\u003c\/span\u003e\u003c\/b\u003e | \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eSeries 90-30\u003c\/span\u003e\u003c\/b\u003e Programmable Logic Controllers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eController Part Number:\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eIC693CPU363\u003c\/span\u003e\u003c\/b\u003e (Single-slot modular architecture)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMicroprocessor \u0026amp; Clock Speed:\u003c\/b\u003e Intel 80386EX architecture operating at 25 MHz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eLogic Execution Speed:\u003c\/b\u003e 0.22 ms per 1K of logic for standard Boolean contacts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMemory Capacity \u0026amp; Storage:\u003c\/b\u003e 240 KB configurable user\/register memory utilizing RAM for user programs and Flash memory for non-volatile firmware storage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDiscrete I\/O Capacity:\u003c\/b\u003e Supports up to 2,048 discrete input points and 2,048 discrete output points\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eSystem Expansion Limits:\u003c\/b\u003e Manages up to 8 total baseplates, supporting 1 local CPU rack and up to 7 remote or distributed expansion racks\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eThermal Operating Envelope:\u003c\/b\u003e Rated for 0 °C to 60 °C (32 °F to 140 °F) ambient operation; -40 °C to 85 °C (-40 °F to 185 °F) storage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eBackplane Power Draw:\u003c\/b\u003e Consumes 890 mA nominal current from the +5 VDC backplane power supply rail (note: standard catalog rating is 890 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eCommunication Ports \u0026amp; Protocol Capabilities\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctr\u003e\n    \u003cth\u003e\u003cb\u003eInterface Port\u003c\/b\u003e\u003c\/th\u003e\n    \u003cth\u003e\u003cb\u003ePhysical Connector\u003c\/b\u003e\u003c\/th\u003e\n    \u003cth\u003e\u003cb\u003eElectrical Standard\u003c\/b\u003e\u003c\/th\u003e\n    \u003cth\u003e\u003cb\u003eSupported Protocols \u0026amp; Functions\u003c\/b\u003e\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eOnboard Serial Port 1\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eRJ45 Modular Jack\u003c\/td\u003e\n    \u003ctd\u003eRS-232 \/ RS-485\u003c\/td\u003e\n    \u003ctd\u003eSNP\/SNPX Master\/Slave, RTU Slave; operates independently for SCADA or HMI links.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eOnboard Serial Port 2\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e15-Pin Sub-D Connector\u003c\/td\u003e\n    \u003ctd\u003eRS-232 \/ RS-485\u003c\/td\u003e\n    \u003ctd\u003eSNP\/SNPX Master\/Slave, RTU Slave; supports concurrent multi-drop network polling.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003ePower Supply Port\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003e15-Pin D-Type Female\u003c\/td\u003e\n    \u003ctd\u003eRS-485\u003c\/td\u003e\n    \u003ctd\u003eSNP\/SNPX Slave; dedicated programming interface located behind the power supply hinged door.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cb\u003eBackplane Option Bus\u003c\/b\u003e\u003c\/td\u003e\n    \u003ctd\u003eRack Backplane\u003c\/td\u003e\n    \u003ctd\u003eProprietary Bus\u003c\/td\u003e\n    \u003ctd\u003eSupports optional Ethernet, Profibus, FIP, GBC, GCM, and GCM+ communication modules.\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eDeployment \u0026amp; Commissioning Practices\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eSlot Allocation:\u003c\/b\u003e Insert the single-slot \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eIC693CPU363\u003c\/span\u003e\u003c\/b\u003e exclusively into Slot 1 of the main \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eSeries 90-30\u003c\/span\u003e\u003c\/b\u003e CPU baseplate immediately adjacent to the power supply module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eFirmware Capabilities:\u003c\/b\u003e Verify firmware Release 9.0 or higher when executing floating-point mathematical instructions or configuring periodic subroutine execution blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMemory Partitioning:\u003c\/b\u003e Allocate internal register memory boundaries during hardware configuration to balance ladder logic storage against %R, %AI, and %AQ data table requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eConcurrent Port Tuning:\u003c\/b\u003e Configure Port 1 and Port 2 baud rates and parity settings independently to prevent bus contention when polling third-party Modbus RTU devices alongside local operator panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eFrequently Asked Questions (FAQ)\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How do engineers connect a programming laptop to the power supply serial port without disturbing active HMI communications?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Open the hinged door on the front right of the rack power supply to access the 15-pin female RS-485 port, which runs SNP\/SNPX slave protocols independently of the two onboard CPU serial ports.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: What causes a fault when adding seven remote expansion baseplates to an existing system?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Expansion failures typically stem from exceeding maximum cable run distances or failing to terminate the end-of-chain expansion receiver module properly on the eighth total rack.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Can the onboard RJ45 and 15-pin serial ports operate at different baud rates simultaneously?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, Port 1 and Port 2 feature independent UART controllers, allowing engineers to run Modbus RTU slave polling on one port while maintaining SNP master communications on the other.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: How is user ladder logic retained during an extended facility power outage?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: While CPU firmware resides safely in non-volatile Flash memory, user logic and register values rely on a lithium backup battery mounted inside the power supply or CPU assembly to maintain RAM contents.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ: Does the processor require additional hardware to communicate over industrial Ethernet networks?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, because the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eIC693CPU363\u003c\/span\u003e\u003c\/b\u003e lacks an embedded Ethernet port, engineers must install an optional Series 90-30 Ethernet interface module into an available baseplate slot.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eSystem Integration \u0026amp; Inquiry Guidance\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen specifying the \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eIC693CPU363\u003c\/span\u003e\u003c\/b\u003e processor for your \u003cb\u003e\u003cspan style=\"color:#003366;\"\u003eGE Fanuc Series 90-30\u003c\/span\u003e\u003c\/b\u003e control cabinet, confirm your total +5 VDC backplane current budget and verify whether floating-point math requires firmware Release 9.0. Contact our technical sales team today to request a formal quotation, verify inventory availability, and arrange fast worldwide shipping.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45013993750710,"sku":"IC693CPU363","price":275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC693CPU363-1.jpg?v=1794983663","url":"https:\/\/www.plcsparehub.com\/products\/ic693cpu363-plc-processor-module-ge-fanuc-series-90-30-240kb-cpu","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}