{"product_id":"ic693cpu321-ge-fanuc-series-90-30-integrated-plc-baseplate","title":"IC693CPU321 GE Fanuc Series 90-30 Integrated PLC Baseplate","description":"\u003ch3\u003e\u003cstrong\u003eGE Fanuc IC693CPU321 – 10-Slot Embedded CPU Baseplate\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CPU321\u003c\/strong\u003e is an integrated CPU baseplate for the \u003cstrong\u003eSeries 90-30 PLC\u003c\/strong\u003e platform. It combines the processor, memory circuits, and backplane within one 10-slot assembly.\u003c\/p\u003e\n\u003cp\u003eUnlike modular CPU designs, this configuration integrates the CPU directly into the baseplate. It uses an \u003cstrong\u003e80188 microprocessor running at 10 MHz\u003c\/strong\u003e to execute control logic and non-Boolean operations.\u003c\/p\u003e\n\u003cp\u003eThe assembly provides up to \u003cstrong\u003e12 KB of battery-backed user logic memory\u003c\/strong\u003e. Its fixed architecture supports compact PLC installations without additional expansion or remote racks.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC693CPU321\u003c\/strong\u003e suits control applications with defined I\/O requirements and limited rack expansion needs. Its integrated design reduces the number of separately installed CPU components.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Architecture at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated CPU and 10-slot baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80188 microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClock Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgram Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 KB battery-backed user logic memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated backplane with soldered CPU and memory circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo expansion connector; expansion and remote racks are not supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne 15-pin D-type female RS-485 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e430 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Discrete I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 input points and 320 output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Analog I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 analog inputs and 32 analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseplate Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 I\/O slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 lb (approximately 1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePLC Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Series 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessor and Memory Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe processing architecture determines the controller's execution capability and application memory limits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e80188 Processor:\u003c\/strong\u003e Executes PLC control logic at a 10 MHz clock speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 KB User Memory:\u003c\/strong\u003e Stores the application logic within the integrated CPU architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery-Backed Memory:\u003c\/strong\u003e Uses battery backup to retain user logic data during power interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Memory Circuits:\u003c\/strong\u003e RAM, EPROM, and EEPROM form part of the baseplate circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Boolean Processing:\u003c\/strong\u003e Supports arithmetic and other non-Boolean operations within the controller's execution architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Consideration:\u003c\/strong\u003e The 12 KB memory capacity limits application size. Evaluate program complexity before selecting this baseplate for a new control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Capacity and Rack Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC693CPU321\u003c\/strong\u003e provides a fixed 10-slot I\/O architecture. It supports applications with defined signal counts and no additional rack requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Category\u003c\/th\u003e\n\u003cth\u003eMaximum Supported Capacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e320 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e320 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e64 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe discrete and analog figures represent different I\/O configurations. Actual capacity depends on the selected modules and slot allocation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Rack Limitation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe baseplate provides 10 I\/O slots.\u003c\/li\u003e\n\u003cli\u003eThe CPU is integrated into the baseplate assembly.\u003c\/li\u003e\n\u003cli\u003eNo expansion connector is available.\u003c\/li\u003e\n\u003cli\u003eRemote rack connections are not supported.\u003c\/li\u003e\n\u003cli\u003eAdditional I\/O requirements need a different system architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Programming Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe integrated power supply provides one \u003cstrong\u003e15-pin D-type female RS-485 serial connector\u003c\/strong\u003e. Engineers can use this interface for programming and compatible serial communication devices.\u003c\/p\u003e\n\u003cp\u003eSupported connection options include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGE Fanuc personal computer programming interfaces.\u003c\/li\u003e\n\u003cli\u003eGE Fanuc Hand-Held Programmer.\u003c\/li\u003e\n\u003cli\u003eCompatible serial communication devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional communication capabilities may be available through compatible Series 90-30 communication modules.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSNP and compatible serial configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTU Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable through supported system configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenius Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional LAN\/Genius communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet SRTP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported through compatible Ethernet modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Modbus TCP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported through compatible Ethernet modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfibus-DP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable through compatible communication hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviceNet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable through compatible communication hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOptional communication modules require separate hardware verification. They do not remove the baseplate's expansion and remote rack limitations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProgramming Software Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC693CPU321\u003c\/strong\u003e supports several generations of GE Fanuc PLC programming environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogicmaster 90-30:\u003c\/strong\u003e DOS-based programming and configuration software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersaPro:\u003c\/strong\u003e Windows-based PLC programming environment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProficy Machine Edition:\u003c\/strong\u003e Supports configuration and programming within the applicable Series 90-30 software environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSoftware compatibility depends on the installed programming version and communication interface. Confirm the project environment before downloading an application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the Model:\u003c\/strong\u003e Verify the complete IC693CPU321 catalog number before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the Baseplate:\u003c\/strong\u003e Check connectors, slot contacts, and the backplane for physical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Power:\u003c\/strong\u003e Confirm the 5 VDC supply and available 430 mA backplane current capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck I\/O Allocation:\u003c\/strong\u003e Ensure the planned modules fit within the 10-slot architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the Programmer:\u003c\/strong\u003e Use the appropriate 15-pin serial interface and compatible programming cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad the Application:\u003c\/strong\u003e Confirm the program fits within the 12 KB user memory limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest the I\/O:\u003c\/strong\u003e Verify input states, output responses, and module communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate Operation:\u003c\/strong\u003e Run functional tests before returning the PLC to production.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Tip:\u003c\/strong\u003e Back up the PLC application before changing the battery or performing memory-related maintenance. Follow the manufacturer's battery replacement procedure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Suitability and Selection Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis integrated baseplate is suitable for compact control systems with stable I\/O requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Machine Control:\u003c\/strong\u003e Suitable for machines with fixed I\/O configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandalone Automation:\u003c\/strong\u003e Supports control applications without additional remote racks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Control Panels:\u003c\/strong\u003e Integrates CPU and backplane functions into one assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall Process Systems:\u003c\/strong\u003e Supports applications within its memory and I\/O limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC System Maintenance:\u003c\/strong\u003e Provides a replacement option for compatible existing installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore purchasing, compare the required I\/O count, program size, communication interfaces, and rack architecture. Applications requiring additional racks need a different CPU baseplate configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Identification and Package Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Model:\u003c\/strong\u003e IC693CPU321\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e Series 90-30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Category:\u003c\/strong\u003e Embedded CPU Baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Package:\u003c\/strong\u003e 1 × IC693CPU321 CPU Baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Accessories:\u003c\/strong\u003e Not included unless specified in the order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ – IC693CPU321\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What happens if the application requires more than 10 I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IC693CPU321 cannot connect to expansion or remote racks. Its backplane has no expansion connector. Engineers should evaluate a Series 90-30 CPU architecture with rack expansion support when the application exceeds the available slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Why should engineers check the battery before uploading a PLC program?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CPU uses battery-backed memory for user logic retention. A weak battery can create a risk of losing retained application data during power interruptions. Back up the program and verify battery condition before maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can a standard RS-232 programming cable connect directly to the CPU?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot necessarily. The integrated connector uses a 15-pin D-type RS-485 interface. Engineers should identify the required programming cable or converter before connecting a computer. Connector shape alone does not establish electrical compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should be checked when the CPU communicates with a programmer but cannot exchange data with an external device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the communication protocol, device configuration, serial wiring, and supported interface hardware. Also verify whether the required network depends on an optional communication module. Successful programming communication does not guarantee compatibility with every external protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Is the IC693CPU321 suitable for replacing another Series 90-30 CPU baseplate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnly when the existing system matches its hardware and application limits. Compare the slot count, I\/O arrangement, memory requirement, communication hardware, and program compatibility. Pay particular attention to expansion rack requirements. A physically compatible installation does not always provide equivalent system functionality.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013985919158,"sku":"IC693CPU321","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC693CPU321-1.jpg?v=1795412405","url":"https:\/\/www.plcsparehub.com\/products\/ic693cpu321-ge-fanuc-series-90-30-integrated-plc-baseplate","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}