{"product_id":"ic693alg390-ge-fanuc-series-90-30-analog-voltage-output-module-2-channel","title":"IC693ALG390 GE Fanuc Series 90-30 Analog Voltage Output Module | 2-Channel","description":"\u003ch3\u003e\u003cb\u003ePrecision Analog Output for Demanding PLC Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC693ALG390\u003c\/b\u003e\u003c\/span\u003e is a dedicated analog voltage output module for the \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eGE Fanuc Series 90-30\u003c\/b\u003e\u003c\/span\u003e PLC platform.\u003c\/p\u003e\n\u003cp\u003eIt provides two independent analog voltage outputs for accurate process control.\u003c\/p\u003e\n\u003cp\u003eEach channel delivers a stable output from -10VDC to +10VDC.\u003c\/p\u003e\n\u003cp\u003eIts fast update cycle supports responsive industrial automation.\u003c\/p\u003e\n\u003cp\u003eThe module suits both closed-loop regulation and precision analog signal transmission.\u003c\/p\u003e\n\u003cp\u003eIntegrated electrical isolation improves system reliability in electrically noisy environments.\u003c\/p\u003e\n\u003cp\u003eThe configurable output behavior during CPU STOP mode increases application flexibility.\u003c\/p\u003e\n\u003cp\u003eThe module supports continuous industrial operation where stable analog control remains essential.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eEngineering Snapshot\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-series-90-30-series-90-70\"\u003e\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eSeries 90-30\u003c\/b\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC693ALG390\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Voltage Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2 Independent Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e-10VDC to +10VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e2.5mV per LSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5mV at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated at 2.5mV per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Offset\u003c\/td\u003e\n\u003ctd\u003e1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh Rate\u003c\/td\u003e\n\u003ctd\u003e5ms for both channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500Vrms Field to Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply\u003c\/td\u003e\n\u003ctd\u003e18-30VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Ripple\u003c\/td\u003e\n\u003ctd\u003e10% Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Consumption\u003c\/td\u003e\n\u003ctd\u003e32mA @5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Supply\u003c\/td\u003e\n\u003ctd\u003e120mA @24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003ePerformance Characteristics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHigh-resolution analog voltage generation\u003c\/b\u003e for demanding control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStable ±10V output\u003c\/b\u003e for industrial instrumentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFast 5ms refresh\u003c\/b\u003e minimizes control latency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1500Vrms isolation\u003c\/b\u003e protects the PLC from field disturbances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFactory calibration\u003c\/b\u003e reduces commissioning effort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSelectable output behavior\u003c\/b\u003e during controller STOP mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSuitable Equipment\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC693ALG390\u003c\/b\u003e\u003c\/span\u003e interfaces with equipment requiring precision voltage reference signals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVariable frequency drives\u003c\/li\u003e\n\u003cli\u003eServo drive controllers\u003c\/li\u003e\n\u003cli\u003eElectro-pneumatic positioners\u003c\/li\u003e\n\u003cli\u003eControl valves\u003c\/li\u003e\n\u003cli\u003eAnalog panel meters\u003c\/li\u003e\n\u003cli\u003eIndustrial data acquisition equipment\u003c\/li\u003e\n\u003cli\u003eSignal conditioners\u003c\/li\u003e\n\u003cli\u003eLaboratory testing systems\u003c\/li\u003e\n\u003cli\u003eCalibration benches\u003c\/li\u003e\n\u003cli\u003eDistributed process control equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTypical Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eIndustry\u003c\/th\u003e\n\u003cth\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Processing\u003c\/td\u003e\n\u003ctd\u003eValve positioning and dosing control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment\u003c\/td\u003e\n\u003ctd\u003ePump speed reference output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Generation\u003c\/td\u003e\n\u003ctd\u003eAnalog actuator control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing\u003c\/td\u003e\n\u003ctd\u003eMachine analog command signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResearch Laboratories\u003c\/td\u003e\n\u003ctd\u003eVoltage reference generation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil \u0026amp; Gas\u003c\/td\u003e\n\u003ctd\u003eClosed-loop process regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eField engineers appreciate this module because of its predictable analog stability.\u003c\/p\u003e\n\u003cp\u003eThe HOLD LAST STATE feature reduces unexpected equipment movement during CPU interruptions.\u003c\/p\u003e\n\u003cp\u003eIn several retrofit projects, engineers retained analog output values while replacing processors.\u003c\/p\u003e\n\u003cp\u003eThis minimized production downtime during commissioning.\u003c\/p\u003e\n\u003cp\u003eShielded instrumentation cable significantly improves analog signal quality.\u003c\/p\u003e\n\u003cp\u003eConnecting the shield directly to the designated GND terminal reduces electrical interference.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower LED confirms module operating status.\u003c\/li\u003e\n\u003cli\u003eField-to-logic isolation limits fault propagation.\u003c\/li\u003e\n\u003cli\u003eSelectable FAIL SAFE output simplifies troubleshooting.\u003c\/li\u003e\n\u003cli\u003eStable calibration assists output verification.\u003c\/li\u003e\n\u003cli\u003eExternal power monitoring improves maintenance efficiency.\u003c\/li\u003e\n\u003cli\u003eShielded wiring minimizes measurement instability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Recommendations\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the PLC rack supports Series 90-30 modules.\u003c\/li\u003e\n\u003cli\u003eUse a regulated 24VDC power source.\u003c\/li\u003e\n\u003cli\u003eInstall shielded instrumentation cable.\u003c\/li\u003e\n\u003cli\u003eGround cable shielding at the specified terminal.\u003c\/li\u003e\n\u003cli\u003eSelect the DEF0 jumper before system startup.\u003c\/li\u003e\n\u003cli\u003eConfirm output polarity before energizing equipment.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cb\u003ePackage Includes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eIC693ALG390\u003c\/b\u003e\u003c\/span\u003e Analog Voltage Output Module\u003c\/li\u003e\n\u003cli\u003eProtective industrial packaging\u003c\/li\u003e\n\u003cli\u003eQuality inspection before shipment\u003c\/li\u003e\n\u003cli\u003eProduct identification label\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eShipping \u0026amp; Warranty\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eService\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCourier\u003c\/td\u003e\n\u003ctd\u003eFedEx \/ UPS \/ DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Time\u003c\/td\u003e\n\u003ctd\u003e24-48 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eIndustrial Protective Packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e12 Months\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical Support\u003c\/td\u003e\n\u003ctd\u003eAvailable Before and After Delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eProfessional FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ1. Why should engineers choose voltage output instead of current output?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eVoltage output offers excellent compatibility with servo drives, inverters, and analog controllers requiring ±10V references.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ2. What is the most common commissioning recommendation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eVerify the external 24VDC supply before checking PLC logic.\u003c\/p\u003e\n\u003cp\u003eMany startup issues originate from unstable field power instead of module configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ3. How can output stability be improved in electrically noisy cabinets?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation cable with proper grounding.\u003c\/p\u003e\n\u003cp\u003eKeep analog wiring separated from motor power cables whenever possible.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ4. What should engineers evaluate before selecting this module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the controlled equipment accepts bipolar ±10V analog input signals.\u003c\/p\u003e\n\u003cp\u003eAlso verify available rack slots and external power capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ5. Which operating mode is recommended for critical automation systems?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eMany engineers select HOLD LAST STATE when maintaining actuator position is important.\u003c\/p\u003e\n\u003cp\u003eApplications prioritizing equipment safety often configure the output to return to 0V.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eEngineering Selection Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect this module for precise bipolar analog voltage control.\u003c\/li\u003e\n\u003cli\u003eIdeal for applications requiring fast analog updates.\u003c\/li\u003e\n\u003cli\u003eRecommended where electrical isolation improves reliability.\u003c\/li\u003e\n\u003cli\u003eSuitable for precision industrial instrumentation.\u003c\/li\u003e\n\u003cli\u003eExcellent for upgrading existing \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eSeries 90-30\u003c\/b\u003e\u003c\/span\u003e analog output systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0066cc;\"\u003e\u003cb\u003eGE Fanuc IC693ALG390\u003c\/b\u003e\u003c\/span\u003e combines precise voltage output, industrial isolation, and dependable PLC integration for professional automation projects.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014002106550,"sku":"IC693ALG390","price":114.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC693ALG390.jpg?v=1785999782","url":"https:\/\/www.plcsparehub.com\/products\/ic693alg390-ge-fanuc-series-90-30-analog-voltage-output-module-2-channel","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}