{"product_id":"ic200udr005-ge-fanuc-versamax-micro-28-plc-buy-online","title":"IC200UDR005 GE Fanuc VersaMax Micro 28 PLC | Buy Online","description":"\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d9534f;\"\u003eGE Fanuc\u003c\/span\u003e \u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e\u003c\/strong\u003e is a compact all-in-one programmable logic controller belonging to the \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003eVersaMax Micro\u003c\/span\u003e\u003c\/strong\u003e PLC controller series. Featuring 28 integrated base I\/O points, this unit combines 16 24VDC inputs, 11 relay outputs, and 1 dedicated 24VDC output into a space-saving housing. Powered by a 120\/240 VAC supply, the \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e\u003c\/strong\u003e incorporates dual serial ports, dual potentiometers, 9K words of logic execution memory, and support for up to 8 local expansion modules.\u003c\/p\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003eTechnical Specifications (MECE Framework)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003e1. Basic System Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #d9534f;\"\u003eGE Fanuc\u003c\/span\u003e\u003c\/strong\u003e \/ Emerson\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersaMax\u003c\/a\u003e Micro\u003c\/span\u003e\u003c\/strong\u003e 28 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e Micro Programmable Logic Controller (PLC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003e2. Processing, Memory \u0026amp; Electrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eTechnical Specification Standard\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase I\/O Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 Base Points (16 Discrete Inputs \/ 12 Discrete Outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSixteen 24VDC discrete input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Breakdown\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEleven electromechanical relay outputs + One 24VDC transistor output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Operating Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC wide AC supply voltage input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 VA maximum operating power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Program Logic Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9K Words user logic program storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Data Registers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2K Words register memory capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capacity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 Discrete I\/O + 4 Analog I\/O modules (140 max physical I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Expansion Potential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports up to 16 analog input channels and 8 analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntegrated Trimmers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 analog potentiometers for manual field parameter adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003e3. Communications \u0026amp; Networking Protocol Suite\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort 1 Architecture:\u003c\/strong\u003e RJ-45 connector operating on RS-232 serial standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort 1 Protocol Support:\u003c\/strong\u003e SNP, breakless SNP-X slave protocols for programming and HMI interfacing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort 2 Architecture:\u003c\/strong\u003e DB-15 connector operating on RS-485 serial standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort 2 Protocol Support:\u003c\/strong\u003e Modbus RTU Master\/Slave (2-wire and 4-wire), SNP, SNP-X, SNP Master, Serial Read\/Write capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Engineering Suite:\u003c\/strong\u003e Configured via VersaPro 1.1 (or higher) and Proficy Machine Edition Logic Developer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003e4. Physical Construction \u0026amp; Form Factor\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e 150 mm Width x 90 mm Height x 76 mm Depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Net Weight:\u003c\/strong\u003e 0.91 kg (2.00 lbs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Installation:\u003c\/strong\u003e Standard 35mm DIN-rail or direct panel mounting options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003eSystem Diagnostics \u0026amp; Hardware Self-Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e\u003c\/strong\u003e features an array of status indicators and embedded self-diagnostic routines. Front-panel LEDs provide immediate visual state monitoring for logic power, CPU RUN status, and individual channel I\/O logic states. System diagnostics continuously poll internal register memory parity, expansion bus integrity, and power supply levels. Any hardware fault or loop error is captured within the CPU fault table and transmitted to the engineering workstation via SNP or Modbus protocols.\u003c\/p\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003eTarget Machinery \u0026amp; Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated packaging machinery, cartooning lines, and conveyor sorting stations.\u003c\/li\u003e\n\u003cli\u003ePumping station lift control, small wastewater dosing units, and valve sequencing.\u003c\/li\u003e\n\u003cli\u003eOEM machine tool automation, parts feeders, and rotary indexing tables.\u003c\/li\u003e\n\u003cli\u003eHVAC air handling unit (AHU) control and local facility management systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMount the \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e\u003c\/strong\u003e controller onto a grounded 35mm DIN rail inside a protective enclosure. Ensure power leads are disconnected before connecting 120\/240 VAC to the main supply terminals. Route 24VDC discrete input wiring separately from relay output load lines to prevent inductive coupling. When utilizing the DB-15 RS-485 port over long cable runs, install proper terminal termination resistors to preserve signal integrity across Modbus networks.\u003c\/p\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003ePackaging, Logistics \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Scope:\u003c\/strong\u003e 1x Factory Sealed \u003cstrong\u003e\u003cspan style=\"color: #d9534f;\"\u003eGE Fanuc\u003c\/span\u003e \u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e\u003c\/strong\u003e VersaMax Micro 28 Main Unit, 1x Installation Datasheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Protection:\u003c\/strong\u003e 12-Month comprehensive warranty covering all functional and mechanical defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling Time:\u003c\/strong\u003e Express order processing within 24 to 48 hours of order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Carriers:\u003c\/strong\u003e Worldwide door-to-door express delivery managed via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur automation engineering team frequently services legacy \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003eVersaMax Micro\u003c\/span\u003e\u003c\/strong\u003e units installed in high-duty cycle packaging plants. On a recent service call, an engineer reported intermittent relay output failure on channel Q3 of an \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e\u003c\/strong\u003e controller. Diagnostic evaluation showed high inductive back-EMF from an un-suppressed 120VAC solenoid valve welded the relay contacts over time. Installing an external RC surge suppressor across the solenoid coil and re-assigning the load to an unused relay channel fully restored operational reliability. \u003cem\u003eField Tip: Always install flywheel diodes on DC inductive loads or RC snubbers on AC loads driven by the internal relay outputs of the module to maximize contact lifespan.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003eSelection \u0026amp; Buyer's Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting the \u003cstrong\u003e\u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e\u003c\/strong\u003e micro controller, confirm that your project requires an AC power supply (120\/240 VAC) rather than a 24VDC main power input. Verify that 16 DC inputs and 11 relay outputs match your field actuator count. If your system exceeds 28 local points, calculate total expansion needs: this base unit allows up to 4 discrete expansion blocks and 4 analog expansion blocks, scaling up to a maximum physical footprint of 140 I\/O points.\u003c\/p\u003e\n\u003ch3 style=\"color: #003366;\"\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What programming software versions are required to configure the \u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The controller requires VersaPro version 1.1 or higher, or any standard release of Proficy Machine Edition Logic Developer PLC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can Port 2 on the \u003cspan style=\"color: #0275d8;\"\u003eIC200UDR005\u003c\/span\u003e act as a Modbus RTU Master simultaneously with Port 1 programming?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Port 1 (RJ-45) can handle local SNP programming while Port 2 (DB-15) runs Modbus RTU Master protocol to communicate with downstream VFDs or meters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do the two integrated analog potentiometers function within user programs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The onboard pots adjust internal system registers (0 to 255 byte values), enabling operators to manually tune timer presets or counter limits without software tools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the maximum physical expansion limit supported by this base controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The base unit supports up to 4 discrete I\/O modules and 4 analog I\/O modules, reaching a maximum system ceiling of 140 physical I\/O points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What electrical protection precautions should be taken when using the 11 relay outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: External inductive loads require suppressor devices (diodes for DC, varistors\/RC snubbers for AC) to prevent contact degradation and noise feedback into the CPU.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013995782326,"sku":"IC200UDR005","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200UDR005-3.jpg?v=1789367659","url":"https:\/\/www.plcsparehub.com\/products\/ic200udr005-ge-fanuc-versamax-micro-28-plc-buy-online","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}