{"product_id":"ic200pwr002-ge-fanuc-versamax-power-supply-module-24vdc","title":"IC200PWR002 GE Fanuc VersaMax Power Supply Module 24VDC","description":"\u003ch3\u003e\u003cstrong\u003eReliable Power Foundation for VersaMax Automation Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200PWR002\u003c\/span\u003e\u003c\/strong\u003e is a \u003cstrong\u003eGE Fanuc VersaMax Supplemental Power Supply Module\u003c\/strong\u003e engineered to provide stable internal power for CPUs, NIUs, and distributed I\/O assemblies.\u003c\/p\u003e\n\u003cp\u003eThe module supports both primary and booster power configurations, helping engineers expand VersaMax systems while maintaining reliable backplane power delivery.\u003c\/p\u003e\n\u003cp\u003eDesigned for continuous industrial operation, \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200PWR002\u003c\/span\u003e\u003c\/strong\u003e combines compact installation, intelligent protection, and dependable DC power conversion into one versatile power module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eEngineering Benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual Output Rails\u003c\/td\u003e\n\u003ctd\u003eProvides stable 5VDC and 3.3VDC system power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary or Booster Operation\u003c\/td\u003e\n\u003ctd\u003eSupports flexible VersaMax power architecture.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Protection\u003c\/td\u003e\n\u003ctd\u003eImproves long-term controller reliability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact Mechanical Design\u003c\/td\u003e\n\u003ctd\u003eOptimizes available cabinet space.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWide Input Range\u003c\/td\u003e\n\u003ctd\u003eMaintains stable operation under varying DC supply conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200PWR002\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersaMax\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplemental Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLifecycle Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC and 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 A Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 VDC Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1.5 A minus 3.3V current consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3.3 VDC Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 A Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHold-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A @24VDC \/ 25 A @30VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort Circuit, Overload, Reverse Polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated Power Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax CPU, NIU or Booster Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Screw-Type Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax CPU, NIU and I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 × 133.4 × 39 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eIdeal Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVersaMax PLC control systems\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O stations\u003c\/li\u003e\n\u003cli\u003eMachine automation equipment\u003c\/li\u003e\n\u003cli\u003ePackaging production lines\u003c\/li\u003e\n\u003cli\u003eWater treatment facilities\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels\u003c\/li\u003e\n\u003cli\u003eOEM machinery\u003c\/li\u003e\n\u003cli\u003eRemote I\/O installations\u003c\/li\u003e\n\u003cli\u003eFactory automation upgrades\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMany unexpected PLC shutdowns originate from unstable power distribution rather than controller hardware. A properly selected power supply significantly improves overall system availability.\u003c\/p\u003e\n\u003cp\u003eDuring a food processing modernization project, engineers repeatedly replaced CPU modules because of intermittent controller resets. Electrical measurements later showed excessive voltage drop under peak load. After upgrading the power distribution using the correct VersaMax supply configuration, the PLC operated continuously without further interruptions.\u003c\/p\u003e\n\u003cp\u003eWhen calculating system power requirements, always reserve additional capacity for future I\/O expansion and startup current demand. This engineering practice reduces long-term operating risk.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBuilt-In Diagnostic Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic Feature\u003c\/th\u003e\n\u003cth\u003eEngineering Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution Monitoring\u003c\/td\u003e\n\u003ctd\u003eMaintains stable backplane operation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eProtects connected PLC hardware.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eReduces installation-related failures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eImproves long-term reliability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Hold-Up Response\u003c\/td\u003e\n\u003ctd\u003eHelps bridge short supply disturbances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify total system current before installation.\u003c\/li\u003e\n\u003cli\u003eConnect protective earth according to cabinet standards.\u003c\/li\u003e\n\u003cli\u003eUse correctly sized DC power cables.\u003c\/li\u003e\n\u003cli\u003eInstall inside a ventilated industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eAllow spare power capacity for future expansion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for GE Fanuc VersaMax automation systems.\u003c\/li\u003e\n\u003cli\u003eSupports VersaMax CPUs and Network Interface Units.\u003c\/li\u003e\n\u003cli\u003eCompatible with VersaMax distributed I\/O assemblies.\u003c\/li\u003e\n\u003cli\u003eOperates as both primary and supplemental power source.\u003c\/li\u003e\n\u003cli\u003eSuitable for industrial PLC control architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Shipping \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200PWR002\u003c\/strong\u003e\u003c\/span\u003e Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial anti-static packaging with reinforced protective cushioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-Month Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCourier Services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrders typically dispatch within 24–48 hours.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should IC200PWR002 operate as a supplemental power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstall it on a VersaMax Booster Carrier whenever additional backplane power is required for expanded I\/O configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can engineers determine whether the existing power supply is overloaded?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCalculate the combined current consumption of all installed CPUs, NIUs, and I\/O modules before commissioning. Reserve additional capacity for future expansion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field practice improves long-term power reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExperienced engineers periodically inspect screw terminal tightness, DC input voltage stability, and cabinet temperature during preventive maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is reverse polarity protection important during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt helps protect the module from accidental wiring mistakes, reducing commissioning risks and minimizing equipment downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should engineers evaluate before selecting IC200PWR002?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReview total backplane power demand, module quantity, installation architecture, available DC supply, cabinet space, and future system expansion requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Selection Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200PWR002\u003c\/span\u003e\u003c\/strong\u003e for reliable VersaMax backplane power distribution.\u003c\/li\u003e\n\u003cli\u003eChoose this module when distributed I\/O expansion requires supplemental system power.\u003c\/li\u003e\n\u003cli\u003eVerify total current demand before system commissioning.\u003c\/li\u003e\n\u003cli\u003eReserve power margin for future automation upgrades.\u003c\/li\u003e\n\u003cli\u003eImplement proper DC wiring and grounding to maximize long-term operational stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013993324726,"sku":"IC200PWR002","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200PWR002.jpg?v=1786008616","url":"https:\/\/www.plcsparehub.com\/products\/ic200pwr002-ge-fanuc-versamax-power-supply-module-24vdc","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}