{"product_id":"ic200mdl940-ge-versamax-relay-module-16-point-isolated-output","title":"IC200MDL940 GE VersaMax Relay Module 16-Point Isolated Output","description":"\u003ch3 style=\"color: #27ae60; border-bottom: 2px solid #27ae60; padding-bottom: 5px;\"\u003eTechnical Overview: High-Density Relay Switching\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #27ae60;\"\u003eIC200MDL940\u003c\/span\u003e\u003c\/strong\u003e stands as a benchmark for flexible signal routing within the \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersaMax\u003c\/a\u003e I\/O ecosystem. Engineered for demanding industrial environments, this module delivers 16 individually isolated Form A (Normally Open) relay contacts. By eliminating the common-point restriction, the \u003cstrong\u003e\u003cspan style=\"color: #27ae60;\"\u003eIC200MDL940\u003c\/span\u003e\u003c\/strong\u003e enables engineers to interface discrete output channels with disparate voltage domains simultaneously—ranging from low-voltage DC control loops to high-voltage AC power circuits.\u003c\/p\u003e\n\u003ch3 style=\"color: #2c3e50;\"\u003eEngineering Specifications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Emerson Automation (formerly GE Intelligent Platforms)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #27ae60;\"\u003eIC200MDL940\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eChannel Density:\u003c\/strong\u003e 16 Isolated Points\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e Form A (N.O.) Silver Alloy\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eSwitching Capacity (Resistive):\u003c\/strong\u003e 2.0A (5-265VAC \/ 5-30VDC); 0.2A (31-125VDC)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e 1500VAC (60 sec) frame ground isolation\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eOperational Temperature:\u003c\/strong\u003e 0 °C to 60 °C\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMax Switching Frequency:\u003c\/strong\u003e 20 cycles\/minute (inductive)\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e Individual channel LED feedback\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eInternal Protection:\u003c\/strong\u003e No internal fuses (external protection required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #2c3e50;\"\u003eLogistics and Operational Assurance\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Comprehensive 12-month performance warranty included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Efficiency:\u003c\/strong\u003e Expedited worldwide delivery via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing:\u003c\/strong\u003e Rapid order dispatch within 24-48 hours.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #2c3e50;\"\u003eGlobal PLC Spare HUB’s Insight\u003c\/h3\u003e\n\u003cp\u003eAt Global PLC Spare HUB, we frequently see the \u003cstrong\u003e\u003cspan style=\"color: #27ae60;\"\u003eIC200MDL940\u003c\/span\u003e\u003c\/strong\u003e utilized in legacy system modernizations. Its primary strength is \"electrical independence.\" Unlike solid-state modules, this relay-based unit provides true physical air-gap isolation, protecting your sensitive PLC logic from high-energy spikes generated by heavy industrial loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Applications:\u003c\/strong\u003e Solenoid valve control, motor starter contactors, signal lamps, and interposing relay arrays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Capability:\u003c\/strong\u003e Integrated front-panel LEDs provide immediate visual status confirmation for each of the 16 channels, facilitating rapid on-site troubleshooting without the need for additional test equipment.\u003c\/p\u003e\n\u003ch3 style=\"color: #2c3e50;\"\u003eProfessional Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is there no leakage current in this module compared to transistor-based I\/O?\u003c\/strong\u003e\u003cbr\u003eA: Since the \u003cstrong\u003e\u003cspan style=\"color: #27ae60;\"\u003eIC200MDL940\u003c\/span\u003e\u003c\/strong\u003e uses physical mechanical relay contacts, the \"OFF\" state is a complete electrical break. This eliminates the \"ghost voltage\" often experienced with triac or transistor outputs in high-impedance loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: When selecting a load for this module, what is the most common cause of premature contact wear?\u003c\/strong\u003e\u003cbr\u003eA: Using the module to switch high-inductance loads without external snubbers or flyback diodes. Though rated for 20 cycles per minute, arcing during high-inductive disconnection significantly reduces silver alloy contact lifespan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I wire one channel to 24VDC and another to 240VAC?\u003c\/strong\u003e\u003cbr\u003eA: Absolutely. The unique benefit of this module is the individual isolation of all 16 points. As long as you respect the dielectric clearance of your wiring harness, each point can safely operate on a different power source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module hot-swappable in a running VersaMax rack?\u003c\/strong\u003e\u003cbr\u003eA: While VersaMax architecture supports some hot-swapping, we recommend de-energizing the external load power supply connected to the terminal block before removing the module to prevent electrical arcing at the backplane pins.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Expert selection guide: When should I prefer the IC200MDL940 over a transistor output module?\u003c\/strong\u003e\u003cbr\u003eA: Choose this relay module when you require high voltage versatility or galvanic isolation. Opt for transistor modules only if your application requires high-speed pulse-width modulation (PWM) or extremely frequent switching beyond the 20 cpm limit of this relay unit.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014001254582,"sku":"IC200MDL940","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200MDL940.jpg?v=1780044330","url":"https:\/\/www.plcsparehub.com\/products\/ic200mdl940-ge-versamax-relay-module-16-point-isolated-output","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}