{"product_id":"ic200mdl930-ge-fanuc-versamax-8-point-relay-output-module","title":"IC200MDL930 GE Fanuc VersaMax 8-Point Relay Output Module","description":"\u003ch3\u003e\u003cb\u003eProduct Introduction | Industrial Relay Switching Platform\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003eGE Fanuc IC200MDL930\u003c\/span\u003e\u003c\/strong\u003e is an 8-point relay output module from the \u003cstrong\u003eVersaMax I\/O series\u003c\/strong\u003e. GE Intelligent Platforms originally developed this product. Emerson Automation currently supports the product portfolio.\u003c\/p\u003e\n\u003cp\u003eThe module provides eight individually isolated, normally open (Form A) relay contacts. Each output operates as a dry contact and switches an externally supplied electrical load.\u003c\/p\u003e\n\u003cp\u003eIts fixed-coil, moving-armature relay design supports both AC and DC switching applications. Silver-alloy contacts provide the electrical switching interface. Individual channel isolation helps separate output circuits within the control system.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200MDL930\u003c\/strong\u003e suits industrial control applications that require independent relay switching. Typical applications include contactor control, alarm circuits, and auxiliary equipment activation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e01 | Product Identity and Hardware Architecture\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003eIC200MDL930\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOriginal Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Intelligent Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Product Portfolio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally Open (Form A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Coil, Moving Armature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilver Alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 cycles per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e02 | Electrical Load Selection Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe relay contacts support different external AC and DC voltage circuits. Engineers must select the load according to the applicable voltage and current limits.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Voltage\u003c\/td\u003e\n\u003ctd\u003e5 \/ 24 \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Voltage\u003c\/td\u003e\n\u003ctd\u003e120 \/ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Switching Range\u003c\/td\u003e\n\u003ctd\u003e0 to 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Switching Range\u003c\/td\u003e\n\u003ctd\u003e0 to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Contact Current\u003c\/td\u003e\n\u003ctd\u003e10 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum AC Contact Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A at 5 to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DC Contact Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A at 5 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Voltage DC Current\u003c\/td\u003e\n\u003ctd\u003e0.2 A at 31 to 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The listed maximum contact currents apply to resistive loads. Do not apply the same current ratings to inductive loads without checking the manufacturer's load derating requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e03 | Relay Switching Characteristics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe dry-contact architecture allows engineers to select suitable external load supplies. The connected circuit must remain within the specified contact ratings.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e04 | Electrical Isolation and Protection\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Input to Logic and Frame Ground\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Input to Logic and Frame Ground\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup-to-Group Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup-to-Group Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Isolation Arrangement\u003c\/td\u003e\n\u003ctd\u003eIndividually Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProtection considerations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe module does not include internal output fuses.\u003c\/li\u003e\n\u003cli\u003eThe module does not include internal snubber circuits.\u003c\/li\u003e\n\u003cli\u003eProvide suitable external branch-circuit protection.\u003c\/li\u003e\n\u003cli\u003eUse appropriate suppression for inductive loads.\u003c\/li\u003e\n\u003cli\u003eCheck load inrush current before selecting the output circuit.\u003c\/li\u003e\n\u003cli\u003eFollow applicable electrical protection and wiring standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContactors, solenoids, and electromagnetic loads can generate switching transients. External suppression helps reduce electrical stress on relay contacts.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e05 | Backplane Power and Operating Conditions\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n\u003ctd\u003e243 mA (listed specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw with Outputs Energized\u003c\/td\u003e\n\u003ctd\u003eApproximately 245 mA (additional supplied specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Requirement\u003c\/td\u003e\n\u003ctd\u003eForced Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMaintain adequate cabinet ventilation during continuous operation. Monitor ambient temperature when installing multiple modules in a compact enclosure.\u003c\/p\u003e\n\u003cp\u003eThermal derating may apply when operating conditions exceed the specified temperature limit. Consult the manufacturer's installation documentation before using the module outside its stated range.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e06 | VersaMax System Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the compatible VersaMax I\/O system. Verify the backplane and terminal assembly before connecting field circuits.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Check:\u003c\/strong\u003e Confirm the VersaMax rack and installation configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Disconnect relevant control and field power supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Positioning:\u003c\/strong\u003e Identify the correct mounting position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Installation:\u003c\/strong\u003e Secure the module according to manufacturer instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Preparation:\u003c\/strong\u003e Identify all eight output circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Verification:\u003c\/strong\u003e Check voltage, current, and load characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Setup:\u003c\/strong\u003e Install suitable fuses and suppression devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Test each relay output individually.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eKeep field wiring consistent with the project electrical drawings. Clearly identify each output channel to simplify commissioning and maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e07 | LED Diagnostics and Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides individual channel indicators and a module OK indicator.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Purpose\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndividual Channel LEDs\u003c\/td\u003e\n\u003ctd\u003eShow the energization status of corresponding output channels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule OK LED\u003c\/td\u003e\n\u003ctd\u003eIndicates the module's backplane power and operating status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended maintenance checks:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompare channel LED status with PLC output commands.\u003c\/li\u003e\n\u003cli\u003eInspect relay terminals for loose connections.\u003c\/li\u003e\n\u003cli\u003eCheck contact performance during scheduled maintenance.\u003c\/li\u003e\n\u003cli\u003eInspect external suppression and protection components.\u003c\/li\u003e\n\u003cli\u003eReview load current against the specified contact limits.\u003c\/li\u003e\n\u003cli\u003eCheck cabinet ventilation and operating temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf an output fails to switch, inspect the field supply and external wiring first. Then check the PLC command, terminal connections, and relay contact condition.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e08 | Industrial Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Switching compatible contactor control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Activating auxiliary process equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Systems:\u003c\/strong\u003e Controlling external alarm and annunciation circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Control:\u003c\/strong\u003e Switching independently controlled electrical loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility Systems:\u003c\/strong\u003e Operating compatible auxiliary electrical equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Panels:\u003c\/strong\u003e Providing isolated relay outputs for control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify the electrical load characteristics before assigning each output. Application suitability depends on voltage, current, switching frequency, and load type.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e09 | Standards and Compliance\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003ctd\u003eSpecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecULus\u003c\/td\u003e\n\u003ctd\u003eSpecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eConfirm the applicable product revision and certification documentation for the installation region. Follow local electrical codes and system-level compliance requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10 | Product Supply and Commercial Information\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e GE Fanuc IC200MDL930.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax I\/O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription:\u003c\/strong\u003e 8-Point Individually Isolated Relay Output Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e New \u0026amp; Original in Factory Packing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Factory Warranty: 12 Months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e 24–48 hours, subject to stock confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eContact our sales team for quotation, availability, and technical assistance. Provide your application voltage and load requirements for additional selection support.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB | Relay Application Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003eIC200MDL930\u003c\/span\u003e\u003c\/strong\u003e provides eight independent Form A relay outputs for AC and DC load switching. Its individual isolation structure supports separate field circuits within a VersaMax control installation.\u003c\/p\u003e\n\u003cp\u003eOne important engineering consideration is the difference between resistive and inductive loads. Contact current ratings cannot be transferred directly between these load categories.\u003c\/p\u003e\n\u003cp\u003eFor inductive applications, engineers should evaluate inrush current, switching transients, and contact protection. The absence of internal fuses and snubbers makes external circuit protection an important design requirement.\u003c\/p\u003e\n\u003cp\u003eProper load selection and thermal management help maintain reliable relay operation. These checks should form part of the initial design and periodic maintenance procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eProfessional FAQ | Relay Selection and Field Engineering\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Why should the minimum contact current be considered when selecting connected loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified minimum contact current is 10 mA per point. Loads below this value may not provide reliable contact performance under all conditions. Check the actual load current before connecting low-current electronic inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Can one output control a contactor coil directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt depends on the coil's voltage, steady-state current, and inrush characteristics. Compare these values with the relay contact ratings. Provide suitable external suppression when required. Use an interposing relay when the load exceeds the permitted switching conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What should technicians investigate when an LED indicates an active output but the load does not operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the external field supply first. Then inspect the load fuse, terminal wiring, and contact continuity. An illuminated channel indicator does not independently confirm that the external load circuit is complete.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. How should engineers distribute loads across the eight output points?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCalculate each circuit's operating current and inrush demand. Keep every channel within its applicable voltage and current limits. Consider the load type and switching frequency when assigning channels. Provide individual branch protection where required by the electrical design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What should be evaluated when replacing this module in an operating VersaMax system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the exact catalog number and hardware configuration. Review the terminal arrangement, field wiring, PLC output assignments, and connected load ratings. Plan a controlled shutdown and test each output after installation. Confirm that the replacement meets the existing system's electrical requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200MDL930.png?v=1794383198\" alt=\"\"\u003e\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013992636598,"sku":"IC200MDL930","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200MDL930-1.jpg?v=1794383198","url":"https:\/\/www.plcsparehub.com\/products\/ic200mdl930-ge-fanuc-versamax-8-point-relay-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}