{"product_id":"ic200mdl740-ge-fanuc-versamax-discrete-output-module-16-point","title":"IC200MDL740 GE Fanuc VersaMax Discrete Output Module 16-Point","description":"\u003ch3\u003e\u003cstrong\u003ePrecision Digital Output Control for VersaMax Automation Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200MDL740\u003c\/span\u003e\u003c\/strong\u003e is a compact \u003cstrong\u003eGE Fanuc VersaMax Discrete Output Module\u003c\/strong\u003e designed for dependable DC output control in industrial automation environments.\u003c\/p\u003e\n\u003cp\u003eThe module combines high-speed switching, hot insertion capability, simplified maintenance, and flexible installation into a compact I\/O solution.\u003c\/p\u003e\n\u003cp\u003eDesigned for machine builders and process engineers, \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200MDL740\u003c\/span\u003e\u003c\/strong\u003e delivers stable positive logic outputs for demanding production applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eEngineering Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16 Digital Outputs\u003c\/td\u003e\n\u003ctd\u003eSupports multiple field devices from one module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositive Logic Design\u003c\/td\u003e\n\u003ctd\u003eIdeal for sourcing-type industrial loads.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Insertion Capability\u003c\/td\u003e\n\u003ctd\u003eReduces maintenance downtime.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact VersaMax Design\u003c\/td\u003e\n\u003ctd\u003eSaves valuable cabinet space.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Switching Response\u003c\/td\u003e\n\u003ctd\u003eImproves machine control accuracy.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL740\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersaMax\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive Logic (Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum ON Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum OFF Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser Configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo Point-to-Point or Group Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput Status LEDs, OK LED, FLD PWR LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFFFF8080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax Modular Carrier System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaintenance Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot Module Replacement Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eDesigned for Industrial Equipment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackaging equipment\u003c\/li\u003e\n\u003cli\u003eConveyor automation\u003c\/li\u003e\n\u003cli\u003eAssembly production lines\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems\u003c\/li\u003e\n\u003cli\u003eMotor starter control\u003c\/li\u003e\n\u003cli\u003eSolenoid valve control\u003c\/li\u003e\n\u003cli\u003eIndustrial relay panels\u003c\/li\u003e\n\u003cli\u003eBuilding automation systems\u003c\/li\u003e\n\u003cli\u003eWater treatment equipment\u003c\/li\u003e\n\u003cli\u003eOEM machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutput module failures are often reported after inductive loads stop operating correctly. In many field cases, the module itself remains fully functional.\u003c\/p\u003e\n\u003cp\u003eDuring a packaging machine service project, repeated output alarms appeared after replacing several contactors. Engineers discovered that suppression components had not been installed across the new solenoid coils. After adding the recommended suppression circuit, switching performance immediately stabilized.\u003c\/p\u003e\n\u003cp\u003eFor inductive devices such as relays, solenoids, and contactors, external suppression significantly extends both module and field device service life.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic Function\u003c\/th\u003e\n\u003cth\u003eEngineering Benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePer-Channel LEDs\u003c\/td\u003e\n\u003ctd\u003eQuick output verification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Indicator\u003c\/td\u003e\n\u003ctd\u003eConfirms module operating condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLD PWR Indicator\u003c\/td\u003e\n\u003ctd\u003eMonitors external field power availability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Replacement Support\u003c\/td\u003e\n\u003ctd\u003eAccelerates maintenance activities.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Filters\u003c\/td\u003e\n\u003ctd\u003eImproves switching reliability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall external suppression circuits across inductive loads.\u003c\/li\u003e\n\u003cli\u003eSeparate output wiring from communication cables.\u003c\/li\u003e\n\u003cli\u003eVerify external field power before startup.\u003c\/li\u003e\n\u003cli\u003eSelect the appropriate VersaMax carrier before installation.\u003c\/li\u003e\n\u003cli\u003eUse properly rated shorting bars when expanding bus terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for GE Fanuc VersaMax PLC systems.\u003c\/li\u003e\n\u003cli\u003eCompatible with VersaMax modular carrier platforms.\u003c\/li\u003e\n\u003cli\u003eSupports industrial DC output applications.\u003c\/li\u003e\n\u003cli\u003eWorks with standard VersaMax configuration software.\u003c\/li\u003e\n\u003cli\u003eSuitable for distributed machine automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Shipping \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL740\u003c\/strong\u003e\u003c\/span\u003e Discrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackaging Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProfessional anti-static packaging with protective cushioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-Month Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCourier Services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFedEx, UPS, DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDispatch Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrders are normally shipped within 24–48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is positive logic output preferred for many PLC applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePositive logic outputs provide sourcing current that matches many industrial sensors, relays, and automation devices commonly used in machine control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the most important protection method for inductive loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstall suppression devices such as flyback diodes or surge suppressors across inductive loads to reduce voltage spikes during switching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can engineers quickly determine whether a field fault originates from the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the FLD PWR indicator, observe the individual output LEDs, verify external supply voltage, and measure the output terminals before replacing hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be considered when selecting a VersaMax output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvaluate output type, required voltage, load characteristics, switching frequency, wiring method, and maintenance strategy before choosing the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich maintenance practice most improves long-term output reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExperienced engineers routinely inspect terminal tightness, suppression components, carrier contacts, and external power quality during preventive maintenance schedules.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Selection Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelect \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eIC200MDL740\u003c\/span\u003e\u003c\/strong\u003e for reliable positive logic DC output control.\u003c\/li\u003e\n\u003cli\u003eUse this module when compact cabinet design is a project priority.\u003c\/li\u003e\n\u003cli\u003eChoose hot insertion capability to minimize maintenance interruptions.\u003c\/li\u003e\n\u003cli\u003eVerify load characteristics before configuring output channels.\u003c\/li\u003e\n\u003cli\u003eImplement surge suppression for every inductive field device to maximize operational reliability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013993226422,"sku":"IC200MDL740","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200MDL740.jpg?v=1786008605","url":"https:\/\/www.plcsparehub.com\/products\/ic200mdl740-ge-fanuc-versamax-discrete-output-module-16-point","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}