{"product_id":"ic200mdl329-ge-fanuc-versamax-output-module","title":"IC200MDL329 GE Fanuc VersaMax Output Module","description":"\u003ch3\u003e\u003cstrong\u003eGE Fanuc IC200MDL329 | VersaMax AC Output Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eGE Fanuc IC200MDL329\u003c\/span\u003e\u003c\/strong\u003e is an eight-point discrete AC output module for the \u003cstrong\u003eVersaMax I\/O and Control System\u003c\/strong\u003e. It converts controller output data into switching signals for compatible AC field loads. Each output has individual channel isolation, supporting separate control circuits within one I\/O module.\u003c\/p\u003e\n\u003cp\u003eThe module operates with a nominal output voltage of \u003cstrong\u003e120 V AC\u003c\/strong\u003e and accepts an output range of 85–132 V AC at 47–63 Hz. It requires an external, user-supplied AC load power source. The module itself does not provide built-in load power.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Hardware at a Glance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersaMax\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIC200MDL329\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 individually isolated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Grouping\u003c\/td\u003e\n\u003ctd\u003eOne group of eight outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85–132 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Backplane Current\u003c\/td\u003e\n\u003ctd\u003e70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e5.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e2.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e2.0 mA at 132 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Response Time\u003c\/td\u003e\n\u003ctd\u003eHalf cycle for ON and OFF states\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint-to-Point Isolation\u003c\/td\u003e\n\u003ctd\u003e250 V AC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Load Power Supply\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eNo built-in channel diagnostic functions specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Components\u003c\/td\u003e\n\u003ctd\u003eSnubber and metal oxide varistor (MOV) on each output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e8 numbered output LEDs and 1 green backplane LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eVersaMax I\/O carrier; DIN rail mounting supported by the system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Dimensions\u003c\/td\u003e\n\u003ctd\u003e110 × 66.8 × 50.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | How the Output Circuit Works\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200MDL329\u003c\/strong\u003e receives eight bits of output data from the PLC CPU or Network Interface Unit (NIU). Its output circuits then switch compatible AC loads according to the controller's commands.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl path:\u003c\/strong\u003e The CPU or NIU processes the control logic and updates the output data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput switching:\u003c\/strong\u003e Each channel controls a connected field circuit within the specified voltage and current limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel isolation:\u003c\/strong\u003e Individual output isolation helps separate field circuits, subject to the manufacturer's wiring and isolation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransient suppression:\u003c\/strong\u003e Built-in snubbers and MOVs help suppress switching transients at the output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual indication:\u003c\/strong\u003e Numbered LEDs show output states, while the green backplane LED indicates backplane power status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e An illuminated output LED does not confirm that the field load receives the correct voltage or operates properly. Verify the field circuit independently during troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Typical Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module suits VersaMax installations that require discrete AC switching rather than analog process control. Actual suitability depends on the connected load's voltage, current, inrush, and switching characteristics.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control panels:\u003c\/strong\u003e Drive compatible contactor coils through appropriately rated interface devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine automation:\u003c\/strong\u003e Switch AC-powered status lamps, signaling devices, and control relays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging and conveying systems:\u003c\/strong\u003e Control discrete actuators or auxiliary circuits where the electrical load meets module ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility and process skids:\u003c\/strong\u003e Operate compatible AC control devices under PLC sequence logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial equipment retrofits:\u003c\/strong\u003e Replace a matching output module after verifying carrier, wiring, configuration, and electrical ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor inductive loads, confirm the load's steady-state current and inrush current before connecting it directly. Use an interposing relay or contactor when the load exceeds the module's switching limits or requires additional isolation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Installation and Commissioning Checklist\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the hardware:\u003c\/strong\u003e Confirm the exact \u003cstrong\u003eIC200MDL329\u003c\/strong\u003e model, compatible VersaMax carrier, and controller or NIU configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate power:\u003c\/strong\u003e De-energize the panel and follow site lockout\/tagout procedures before installation or wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the load supply:\u003c\/strong\u003e Confirm that the external AC supply matches the 85–132 V AC operating range and 47–63 Hz frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview channel loading:\u003c\/strong\u003e Keep each point within the 0.5 A maximum rating. Assess inrush and combined circuit loading against the applicable manufacturer documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect wiring:\u003c\/strong\u003e Check terminal tightness, conductor sizing, grounding practices, and separation between field wiring and low-voltage control wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest outputs individually:\u003c\/strong\u003e Command each channel from the PLC program and compare its LED state with the measured field voltage and actual load response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord baseline results:\u003c\/strong\u003e Document supply voltage, channel assignments, load current, and any unexpected leakage or switching behavior.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eNever use the 70 mA backplane current rating as the field-load current rating. The backplane powers the module electronics; the external AC supply powers the connected loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Field Diagnostics: Symptom-to-Cause Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Symptom\u003c\/th\u003e\n\u003cth\u003ePotential Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll outputs remain inactive\u003c\/td\u003e\n\u003ctd\u003eMissing backplane power, incorrect output logic, or absent external AC supply\u003c\/td\u003e\n\u003ctd\u003eCheck the green backplane LED, controller status, output data, and AC load supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne output LED changes, but the load does not operate\u003c\/td\u003e\n\u003ctd\u003eOpen field wiring, failed load, missing AC supply, or a defective output circuit\u003c\/td\u003e\n\u003ctd\u003eMeasure voltage at the output and load terminals, then inspect wiring and load continuity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad remains energized after an OFF command\u003c\/td\u003e\n\u003ctd\u003eResidual leakage, wiring error, or a failed switching device\u003c\/td\u003e\n\u003ctd\u003eVerify the output command, measure off-state voltage, and isolate the load for controlled testing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput switches intermittently\u003c\/td\u003e\n\u003ctd\u003eUnstable supply, loose connections, excessive inrush, or an unsuitable load\u003c\/td\u003e\n\u003ctd\u003eInspect terminals, record supply voltage under load, and compare current demand with the rated limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeated output failures\u003c\/td\u003e\n\u003ctd\u003eExcessive load current, switching surges, or an unsuitable inductive load\u003c\/td\u003e\n\u003ctd\u003eMeasure steady-state and inrush current; review suppression and interface-device requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic limitation:\u003c\/strong\u003e The supplied specifications do not identify built-in channel fault reporting for this module. Troubleshooting therefore relies on controller data, LEDs, electrical measurements, and field-device checks. The LEDs indicate status; they do not provide complete fault diagnosis.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Selection and Compatibility Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatch the voltage:\u003c\/strong\u003e Select this module for compatible 120 V AC circuits within its specified operating range, not for 24 V DC loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the load type:\u003c\/strong\u003e Confirm coil current, lamp inrush, switching frequency, and inductive characteristics against the manufacturer's limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the carrier:\u003c\/strong\u003e VersaMax I\/O modules require the appropriate carrier base. Verify the physical and electrical compatibility of the installed assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview isolation requirements:\u003c\/strong\u003e The listed 250 V AC continuous point-to-point isolation rating is not a blanket authorization for every wiring arrangement. Follow the official installation documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan for off-state leakage:\u003c\/strong\u003e The specified leakage current is 2.0 mA at 132 V AC. Some sensitive loads may need a suitable interface or load-side design adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate the system configuration:\u003c\/strong\u003e Check the CPU or NIU, I\/O map, output addressing, and replacement module documentation before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen evaluating the \u003cstrong\u003eIC200MDL329\u003c\/strong\u003e, engineers should pay particular attention to load compatibility and the distinction between module status and field-circuit status. The 0.5 A per-point rating does not alone establish suitability for every relay coil or lamp. Inrush current, inductive energy, and switching frequency can influence service life and reliability.\u003c\/p\u003e\n\u003cp\u003eDuring a replacement, record the original channel-to-load assignments before removing the module. After installation, test all eight outputs under representative operating conditions. If an output LED responds but the field device does not, measure the AC circuit before concluding that the controller or module has failed.\u003c\/p\u003e\n\u003cp\u003eFor applications involving safety-related functions, do not treat this standard discrete output module as a safety-rated switching device unless the complete system documentation explicitly supports that use.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How should engineers evaluate whether a contactor coil is suitable for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the coil's rated AC voltage, steady-state current, pull-in current, and inductive characteristics. Compare these values with the module's point rating and official load restrictions. Use an appropriately rated interposing relay if direct switching is unsuitable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What should be checked before replacing an existing VersaMax output module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the full part number, carrier compatibility, field voltage, channel assignments, controller configuration, and load ratings. Photograph or document the wiring before removal, then verify each output after installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why can a high-impedance meter show voltage when an output is OFF?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified off-state leakage current can produce a measurable voltage across a lightly loaded circuit. Check the actual load behavior and wiring, and use an approved test method. Do not assume that the reading alone proves the output has failed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How can technicians distinguish a field-load fault from a module fault?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst confirm the controller command and corresponding output LED. Then check the external AC supply, terminal voltage, wiring continuity, and load condition. If the command and supply are correct but the channel fails under a controlled test, investigate the module and its carrier connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Is this module appropriate for loads that switch frequently or draw high starting current?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. Evaluate inrush current, operating duty, inductive characteristics, and the manufacturer's switching limitations. For demanding loads, consider an external interface device and confirm its ratings before finalizing the design.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e9 | Supply, Warranty, and Package Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e GE Fanuc IC200MDL329 VersaMax Discrete AC Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's applicable terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and shipment arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage contents:\u003c\/strong\u003e One IC200MDL329 module. Additional accessories or carrier bases are included only when specifically stated in the quotation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBefore ordering:\u003c\/strong\u003e Provide the complete part number and application details to confirm compatibility and availability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a quote from Global PLC Spare HUB\u003c\/strong\u003e for the \u003cstrong\u003eIC200MDL329\u003c\/strong\u003e. Share your existing system configuration and load requirements to help confirm the correct module for your application.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013993095350,"sku":"IC200MDL329","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200MDL329-3.jpg?v=1792727305","url":"https:\/\/www.plcsparehub.com\/products\/ic200mdl329-ge-fanuc-versamax-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}