{"product_id":"ic200mdl244-ge-fanuc-versamax-8-channel-ac-discrete-input-module","title":"IC200MDL244 GE Fanuc Versamax 8-Channel AC Discrete Input Module","description":"\u003ch3\u003e\u003cspan style=\"color: #1e3a8a;\"\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Module Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #b91c1c;\"\u003e\u003cstrong\u003eIC200MDL244\u003c\/strong\u003e\u003c\/span\u003e serves as an 8-channel AC discrete input module within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eVersamax\u003c\/strong\u003e\u003c\/span\u003e automation platform. \u003cspan style=\"color: #047857;\"\u003e**GE Fanuc**\u003c\/span\u003e designed this compact unit to interface high-voltage AC field sensors directly with CPU backplanes. Global PLC Spare HUB field engineers emphasize its individual channel isolation for high-noise electrical distribution environments. Maintenance professionals rely on its space-saving carrier footprint to maximize control panel density.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #1e3a8a;\"\u003e\u003cstrong\u003eTechnical Specifications \u0026amp; Operating Parameters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical Parameter\u003c\/th\u003e\n\u003cth\u003eEngineering Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \u0026amp; Series\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #047857;\"\u003e**GE Fanuc**\u003c\/span\u003e \/ \u003cspan style=\"color: #0056b3;\"\u003e**\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersamax\u003c\/a\u003e**\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #b91c1c;\"\u003e\u003cstrong\u003eIC200MDL244\u003c\/strong\u003e\u003c\/span\u003e (Also indexed as \u003cspan style=\"color: #b91c1c;\"\u003e\u003cstrong\u003eIC200MDL244\u003c\/strong\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Count\u003c\/td\u003e\n\u003ctd\u003e8 individually isolated sourcing\/positive logic inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage \u0026amp; Range\u003c\/td\u003e\n\u003ctd\u003e240 Volts AC nominal, operating range 0 to 264 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Parameters\u003c\/td\u003e\n\u003ctd\u003e155 to 264 Volts AC with 7.0 milliamps minimum load per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e60 milliamps maximum at 5 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time \u0026amp; Isolation\u003c\/td\u003e\n\u003ctd\u003e1 cycle max response time, 500 VAC point-to-point and ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 66.8 x 50.0 Millimeters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan style=\"color: #1e3a8a;\"\u003e\u003cstrong\u003eInstallation \u0026amp; Carrier Integration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the \u003cspan style=\"color: #b91c1c;\"\u003e\u003cstrong\u003eIC200MDL244\u003c\/strong\u003e\u003c\/span\u003e module securely onto box-style, barrier-style, or spring-style I\/O carriers.\u003c\/li\u003e\n\u003cli\u003eEnsure backplane power distribution supports the 60 mA draw without voltage sag.\u003c\/li\u003e\n\u003cli\u003eTerminate 240VAC field sensor wiring directly to carrier screw or spring terminals.\u003c\/li\u003e\n\u003cli\u003eVerify mechanical alignment before latching the module housing onto the DIN rail base.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #1e3a8a;\"\u003e\u003cstrong\u003eModule Diagnostics \u0026amp; Status Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitor the 8 individually numbered front-panel LEDs to track active discrete input states.\u003c\/li\u003e\n\u003cli\u003eObserve the dedicated backplane status LED to confirm healthy internal communication.\u003c\/li\u003e\n\u003cli\u003eCheck input voltage levels with a digital multimeter if a channel fails to register above the 155 VAC on-state threshold.\u003c\/li\u003e\n\u003cli\u003eVerify point-to-point isolation boundaries if ground loop noise triggers phantom input readings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #1e3a8a;\"\u003e\u003cstrong\u003eHardware Compatibility \u0026amp; Application Environments\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFully compatible with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eVersamax\u003c\/strong\u003e\u003c\/span\u003e I\/O racks and CPU controllers.\u003c\/li\u003e\n\u003cli\u003eInterfaces AC limit switches, mechanical pushbuttons, and proximity sensors in industrial machinery.\u003c\/li\u003e\n\u003cli\u003eDeploys in heavy power distribution substations, HVAC control panels, and motor control centers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #1e3a8a;\"\u003e\u003cstrong\u003eLogistics, Warranty \u0026amp; Package Contents\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackage includes one \u003cspan style=\"color: #b91c1c;\"\u003e\u003cstrong\u003eIC200MDL244\u003c\/strong\u003e\u003c\/span\u003e input module and technical specification documents.\u003c\/li\u003e\n\u003cli\u003eBacked by an industry-standard 12-month operational warranty.\u003c\/li\u003e\n\u003cli\u003eRapid worldwide dispatch within 24 to 48 hours via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"color: #1e3a8a;\"\u003e\u003cstrong\u003eExpert FAQ \u0026amp; Field Purchasing Insights\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What specific advantage do the individually isolated channels of the \u003cspan style=\"color: #b91c1c;\"\u003e\u003cstrong\u003eIC200MDL244\u003c\/strong\u003e\u003c\/span\u003e provide in heavy industrial plants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Individual isolation prevents multi-channel electrical cross-talk and shields internal logic from transient voltage spikes originating on separate 240VAC field circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How should technicians troubleshoot an input channel that remains unlit despite 240VAC applied at the terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Verify that the input current meets or exceeds the 7.0 mA minimum load threshold and check for loose carrier spring connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Buying Guide: What carrier styles should engineers select when deploying this module in high-vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: We recommend spring-style or box-style I\/O carriers to maintain constant wire tension and prevent loosening under continuous mechanical shock.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Does this module require an external user-supplied power source for its internal logic circuitry?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: No, internal operational power is derived directly from the system backplane, drawing a maximum of 60 milliamps at 5 Volts DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can the \u003cspan style=\"color: #b91c1c;\"\u003e\u003cstrong\u003eIC200MDL244\u003c\/strong\u003e\u003c\/span\u003e safely interface with sinking-type DC sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: No, this is specifically an AC input module rated for 240VAC sourcing logic applications and cannot process standard DC input signals.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014000894134,"sku":"IC200MDL244","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200MDL244-3.jpg?v=1788856877","url":"https:\/\/www.plcsparehub.com\/products\/ic200mdl244-ge-fanuc-versamax-8-channel-ac-discrete-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}