{"product_id":"ic200mdl241-ge-fanuc-versamax-discrete-input-module-240-vac","title":"IC200MDL241 GE Fanuc VersaMax Discrete Input Module 240 VAC","description":"\u003ch2\u003eIC200MDL241 GE Fanuc VersaMax 16-Point AC Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL241\u003c\/strong\u003e is a 16-point AC discrete input module for the VersaMax I\/O and Control System. It receives two-state signals from field devices and presents their status to the controller as discrete input data for PLC logic processing.\u003c\/p\u003e\n\u003cp\u003eDesigned for nominal 240 VAC applications, the module provides 16 non-point-to-point-isolated inputs arranged in two groups of eight. Each input has an individually numbered status LED, while a separate backplane LED indicates module backplane operation. The module draws its operating power from the backplane and is installed on a compatible VersaMax I\/O carrier.\u003c\/p\u003e\n\u003ch3\u003e01 | Field Signal to PLC Data\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSignal path:\u003c\/strong\u003e AC field device → IC200MDL241 input channel → group-level input circuitry → VersaMax backplane → controller input data → PLC logic.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-device interface:\u003c\/strong\u003e Accepts supported AC on\/off signals from switches, pushbuttons, and compatible AC-output sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel processing:\u003c\/strong\u003e Handles 16 discrete input points, organized as two groups of eight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus indication:\u003c\/strong\u003e Provides 16 channel LEDs for field-state troubleshooting and one backplane LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController interface:\u003c\/strong\u003e Makes input states available to the control system as discrete input data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module reports discrete states; it is not an analog measurement device. It should not be selected for continuously variable voltage measurement or for signals outside its specified AC input range.\u003c\/p\u003e\n\u003ch3\u003e02 | Electrical and Mechanical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIC200MDL241\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersaMax\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eVersaMax I\/O and Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 discrete input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Arrangement\u003c\/td\u003e\n\u003ctd\u003e2 groups of 8 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eNo point-to-point isolation; group-level isolation is specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0–264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Range\u003c\/td\u003e\n\u003ctd\u003e155–264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0–40 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup Isolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 V for 1 minute, as stated in the supplied specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Backplane Current\u003c\/td\u003e\n\u003ctd\u003e110 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Turn-On Response\u003c\/td\u003e\n\u003ctd\u003e1 cycle, as stated in the supplied specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Power Requirement\u003c\/td\u003e\n\u003ctd\u003eNo separate user-supplied module power is specified; field input signals must still meet the module's requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e16 individually numbered input LEDs and 1 backplane LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eCompatible VersaMax I\/O carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Dimensions\u003c\/td\u003e\n\u003ctd\u003e110 × 66.8 × 50.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical selection note:\u003c\/strong\u003e The specified operating range, on-state range, and off-state range leave a transition region between 40 VAC and 155 VAC. Do not assume that voltages in this region will produce a guaranteed logic state. Confirm the manufacturer's switching thresholds and input timing requirements before using the module in a critical interlock.\u003c\/p\u003e\n\u003ch3\u003e03 | Two Groups, Eight Inputs Each\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL241 has 16 input points divided into two groups. The supplied information specifies group-level isolation but no point-to-point isolation. This distinction matters when field devices belong to different circuits or when troubleshooting ground references and unwanted coupling.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign Consideration\u003c\/th\u003e\n\u003cth\u003eEngineering Implication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo groups of eight\u003c\/td\u003e\n\u003ctd\u003ePlan field wiring and channel allocation around the actual group arrangement shown in the wiring documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo point-to-point isolation\u003c\/td\u003e\n\u003ctd\u003eDo not treat each channel as an independently isolated circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup-level isolation\u003c\/td\u003e\n\u003ctd\u003eVerify the permitted circuit separation and isolation rating against the manufacturer's manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240 VAC field signals\u003c\/td\u003e\n\u003ctd\u003eUse suitable wiring, protection, enclosure design, and lockout procedures for hazardous electrical energy.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not infer terminal assignments or group common wiring from the channel count alone. Use the correct IC200MDL241 wiring diagram and compatible carrier documentation when connecting field circuits.\u003c\/p\u003e\n\u003ch3\u003e04 | Equipment and Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine control panels:\u003c\/strong\u003e Monitoring AC-operated limit switches, selector switches, and pushbutton contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial packaging equipment:\u003c\/strong\u003e Collecting supported AC discrete signals for machine sequencing and operating-state logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial handling systems:\u003c\/strong\u003e Monitoring compatible field switches and discrete position signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess auxiliary equipment:\u003c\/strong\u003e Collecting AC status signals from field devices in compatible VersaMax installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy PLC maintenance:\u003c\/strong\u003e Replacing a confirmed faulty input module while preserving the existing VersaMax I\/O architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese examples describe potential uses based on the module's input function. Actual suitability depends on the field-device output, wiring design, carrier compatibility, controller configuration, and application safety requirements.\u003c\/p\u003e\n\u003ch3\u003e05 | LED-Based Diagnostics and Fault Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 16 channel LEDs provide a direct comparison between the field input condition and the module's indicated input state. The backplane LED provides a separate indication related to module\/backplane operation. Use these indicators as one part of a structured fault-isolation process rather than as proof that the entire control path is functioning correctly.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Condition\u003c\/th\u003e\n\u003cth\u003ePossible Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Checks\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField device is active, but its channel LED is off\u003c\/td\u003e\n\u003ctd\u003eInput voltage is absent or outside the valid on-state range; wiring or field device fault\u003c\/td\u003e\n\u003ctd\u003eUsing approved procedures and a suitably rated meter, verify the signal at the correct input terminals. Check the field device and wiring diagram.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel LED is on, but PLC logic reads the input as off\u003c\/td\u003e\n\u003ctd\u003eController configuration, I\/O addressing, backplane communication, or logic mapping issue\u003c\/td\u003e\n\u003ctd\u003eCheck the configured input reference, controller diagnostics, and application logic.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeveral inputs in one group behave incorrectly\u003c\/td\u003e\n\u003ctd\u003eShared group wiring, common-reference issue, or a problem affecting the group\u003c\/td\u003e\n\u003ctd\u003eReview the group wiring and isolation arrangement. Compare affected points with the other group.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane LED does not show the expected state\u003c\/td\u003e\n\u003ctd\u003eCarrier seating, backplane supply, installation, or module fault\u003c\/td\u003e\n\u003ctd\u003eConsult the module manual for the exact LED meaning, then check seating, carrier compatibility, and backplane status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput state changes intermittently\u003c\/td\u003e\n\u003ctd\u003eUnstable field signal, loose termination, electrical interference, or voltage near a switching threshold\u003c\/td\u003e\n\u003ctd\u003eInspect wiring and terminations, measure the signal under operating conditions, and compare the voltage with the specified input thresholds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic limitation:\u003c\/strong\u003e The supplied data identifies the LED count but does not define every LED color, blink pattern, or diagnostic code. Confirm the indicator meanings in the applicable GE Fanuc documentation. Do not assume a particular LED pattern indicates a specific failure without that reference.\u003c\/p\u003e\n\u003ch3\u003e06 | Replacement and Commissioning Checklist\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the part number:\u003c\/strong\u003e Check the installed label for IC200MDL241. Similar VersaMax input modules may have different voltage ratings or input characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the field voltage:\u003c\/strong\u003e Confirm that the application uses compatible AC signals and that normal operating voltage falls within the module's specified thresholds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the carrier:\u003c\/strong\u003e Verify the I\/O carrier model, terminal arrangement, and installation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReview channel allocation:\u003c\/strong\u003e Record the existing point assignments and group wiring before removing the original module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck backplane capacity:\u003c\/strong\u003e Allow for the module's maximum stated current consumption of 110 mA at 5 VDC within the system power budget.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify controller configuration:\u003c\/strong\u003e Confirm the I\/O configuration and input references after replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest each point:\u003c\/strong\u003e Where operationally safe, verify field-device activation, channel LED response, and the corresponding PLC logic state.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAC field circuits can present a serious shock hazard. Isolate power and follow the site's electrical safety procedures before handling terminals or removing the module. Do not assume that a module or carrier supports hot swapping merely because a product description mentions snap-in terminals or hot-swap capability; verify the approved procedure for the exact hardware and operating configuration.\u003c\/p\u003e\n\u003ch3\u003e07 | Global PLC Spare HUB Review\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL241 is best evaluated as a 240 VAC discrete signal acquisition module, not simply as a 16-channel replacement board. Its operating thresholds, two-group input arrangement, and lack of point-to-point isolation directly affect field wiring and fault diagnosis.\u003c\/p\u003e\n\u003cp\u003eFor replacement work, the most useful pre-order information is the complete part number, carrier model, field voltage, and a record of the existing channel assignments. For troubleshooting, compare the physical field signal, channel LED, and controller input state in sequence. This separates field-circuit problems from I\/O configuration and backplane-related issues more effectively than replacing the module based on a single symptom.\u003c\/p\u003e\n\u003cp\u003eThe module's 110 mA maximum backplane current at 5 VDC should be included in the rack power assessment. Before commissioning, also confirm the isolation requirements and input switching thresholds against the applicable manufacturer documentation, especially where the module interfaces with separate field circuits or critical machine interlocks.\u003c\/p\u003e\n\u003ch3\u003e08 | Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is IC200MDL241 suitable for a 120 VAC field input circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied specifications identify a nominal 240 VAC module, with a stated on-state range beginning at 155 VAC. A 120 VAC signal is below that specified on-state range, so this module should not be selected for a 120 VAC application without authoritative documentation confirming suitability. Choose a module whose specified input thresholds match the actual field voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can two field circuits be treated as fully isolated because the module has group isolation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The provided information states that the module has no point-to-point isolation and provides isolation between groups. That does not mean every input is individually isolated. Check the wiring diagram and isolation specifications before connecting circuits with different references or grounding arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should be recorded before replacing an installed input module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the part number, carrier model, channel-to-device mapping, group wiring, field voltage, and the input status observed before removal. Clear records help prevent swapped channels and make post-replacement testing more efficient.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: If the input LED responds correctly, can the field input be considered fully operational?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot by itself. An illuminated LED indicates that the module is recognizing a channel state, but the controller may still have an addressing, configuration, communication, or logic issue. Confirm that the corresponding PLC input reference changes as expected and that the application logic uses the correct address.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Which details should be supplied when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full IC200MDL241 part number, required quantity, carrier information, field voltage, unit condition requirements, and a photo of the nameplate if available. If replacing a failed unit, include the observed LED behavior and whether the problem affects one channel, a group of channels, or the whole module. This information helps screen out modules with unsuitable voltage ratings or mounting requirements.\u003c\/p\u003e\n\u003ch3\u003e09 | Warranty and Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e GE Fanuc IC200MDL241 VersaMax Discrete AC Input Module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the seller's written terms and the confirmed product condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Target:\u003c\/strong\u003e 24–48 hours after order and payment confirmation, subject to stock status, processing, and applicable shipping requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility Support:\u003c\/strong\u003e Contact us with your system and carrier details before ordering to confirm the required configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a quote for IC200MDL241.\u003c\/strong\u003e Include the required quantity, product condition preference, and VersaMax system details to help verify the correct replacement.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013995749558,"sku":"IC200MDL241","price":268.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200MDL241-1.jpg?v=1792051688","url":"https:\/\/www.plcsparehub.com\/products\/ic200mdl241-ge-fanuc-versamax-discrete-input-module-240-vac","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}