{"product_id":"ic200mdl140-versamax-series-ge-fanuc-8-point-discrete-ac-input-module","title":"IC200MDL140 VersaMax Series GE Fanuc 8-Point Discrete AC Input Module","description":"\u003ch3\u003eCore Product Introduction\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e operates as an 8-point discrete AC input module designed for the modular \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003c\/span\u003e control architecture by GE Fanuc. This module seamlessly bridges 120 VAC binary field signals from industrial switches and pilot devices back to the central controller through high-integrity backplane communication.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Parameters Specification\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical Metric\u003c\/th\u003e\n\u003cth\u003eEngineering Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e \/ \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Point Density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Discrete Inputs (Single Group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 Volts AC (Operating Range: 0 to 132 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State \/ Off-State Voltage Thresholds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn-State: 70 to 132 VAC; Off-State: 0 to 20 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance \u0026amp; Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.6 kΩ typical at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 AC cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 mA maximum at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \u0026amp; Physical Footprint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 x 66.8 x 50.0 millimeters (4.3 x 2.63 x 1.956 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment \u0026amp; Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard industrial rack mounting on interposing terminal base carriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSnap the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e directly onto the designated \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003c\/span\u003e I\/O base carrier with interposing terminals.\u003c\/li\u003e\n\u003cli\u003eEnsure snap-in carrier locks are fully engaged to support hot module insertion and removal safely.\u003c\/li\u003e\n\u003cli\u003eVerify AC line wiring polarity and secure terminal block screws firmly to prevent contact chatter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning and Maintenance Usability\u003c\/h3\u003e\n\u003cp\u003eMaintenance engineers benefit from the streamlined physical layout of the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e. Hot-insertion capabilities allow technicians to replace faulty modules without powering down the entire rack control system, significantly minimizing mean time to repair (MTTR).\u003c\/p\u003e\n\u003ch3\u003eDiagnostic Capabilities and Status Indication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power LED:\u003c\/strong\u003e Illuminates to verify healthy internal power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumbered Point LEDs:\u003c\/strong\u003e 16 individual channel state indicators displaying real-time ON\/OFF status for every active loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Applications and Equipment Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring 120 VAC industrial limit switches and control panel pushbuttons.\u003c\/li\u003e\n\u003cli\u003eInterfacing auxiliary relay contacts in motor control centers (MCC).\u003c\/li\u003e\n\u003cli\u003eTracking status signals from heavy-duty automated manufacturing machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommercial Terms, Logistics, and Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Scope:\u003c\/strong\u003e 1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e input module with protective structural casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Fully backed by a 12-month replacement warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Delivery Services:\u003c\/strong\u003e Expedited express transit handled via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Lead Time:\u003c\/strong\u003e Fast fulfillment within 24 to 48 hours of order confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eField engineering evaluations on the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e highlight exceptional stability in heavy industrial plants running noisy 120 VAC supply lines. During a recent packaging plant overhaul, technicians resolved intermittent input flickering by securing the base carrier ground strap and verifying that line voltage remained within the 70 to 132 VAC on-state threshold. Utilizing the built-in point LEDs allowed rapid verification of incoming sensor signals without requiring a handheld multimeter.\u003c\/p\u003e\n\u003ch3\u003eEngineering Buying Guide\u003c\/h3\u003e\n\u003cp\u003eWhen selecting the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e, ensure your control architecture utilizes compatible \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003c\/span\u003e base carriers. Confirm that field control voltage matches the 120 VAC nominal requirement and that total backplane current capacity accommodates the 55 mA load requirement.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Technical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e require an external power supply for its input channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the input channels are powered directly by the 120 VAC field signals coming from connected switches, while internal logic draws power from the backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What causes an input channel to register as an invalid state?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Voltages hovering between the 20 VAC off-state limit and the 70 VAC on-state threshold can cause undefined states, usually resulting from line sag or induced AC noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200MDL140\u003c\/strong\u003e\u003c\/span\u003e module be hot-swapped during active machine operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, when installed on approved \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003c\/span\u003e I\/O base carriers featuring snap-in backplane design, hot insertion and removal are fully supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why are there 16 numbered LEDs on an 8-point module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes expanded status indicators to provide precise channel monitoring and diagnostic mapping across the modular terminal layout.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I handle input signal filtering if environmental noise causes false triggers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the hardware responds within 1 AC cycle, you can implement software filtering logic inside your PLC project configuration to debounce erratic AC signals.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45013997158582,"sku":"IC200MDL140","price":147.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200MDL140-1.jpg?v=1790666784","url":"https:\/\/www.plcsparehub.com\/products\/ic200mdl140-versamax-series-ge-fanuc-8-point-discrete-ac-input-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}