{"product_id":"ic200erm001-ge-fanuc-versamax-expansion-module-in-stock","title":"IC200ERM001 GE Fanuc VersaMax Expansion Module In Stock","description":"\u003ch3\u003eExecutive Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200ERM001\u003c\/strong\u003e\u003c\/span\u003e is an isolated expansion receiver module developed for the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Fanuc \/ Emerson VersaMax\u003c\/strong\u003e\u003c\/span\u003e modular I\/O and control architecture. Designed to work in tandem with an expansion transmitter module (such as the IC200ETM001), this module enables high-speed backplane extension across multi-rack station configurations.\u003c\/p\u003e\n\u003cp\u003eEquipped with dual 26-pin female D-sub connectors, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200ERM001\u003c\/strong\u003e\u003c\/span\u003e manages incoming data frames from the local CPU rack while facilitating daisy-chain connectivity to downstream expansion racks or bus termination plugs.\u003c\/p\u003e\n\u003ch3\u003eCore Architecture \u0026amp; Hardware Layout\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200ERM001\u003c\/strong\u003e\u003c\/span\u003e serves as the communication head for expansion baseplates, receiving logic signals and passing power parameters across the local rack bus (supplying 3.3 VDC to 5 VDC to backplane modules).\u003c\/p\u003e\n\u003cp\u003eThe top 26-pin D-sub port connects directly to the incoming expansion transmitter cable. The bottom 26-pin D-sub port provides pass-through connection to subsequent expansion racks or houses the mandatory bus termination block at the end of the line. A front-panel rotary switch beneath the access door assigns unique expansion rack IDs for backplane addressing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6; width: 30%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eGE Intelligent Platforms \/ GE Fanuc\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200ERM001\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eIsolated Expansion Receiver Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e2× Female D-Shell Connectors (26-Pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003ePower Sourcing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eInstalled Rack Backplane Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eBackplane Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e3.3 VDC Minimum to 5.0 VDC Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eAddress Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eHardware Rotary Switch (Rack ID selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eRack Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eFar-Left Slot (DIN Rail position 1 on expansion base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eIntegrated LEDs (Power Status \u0026amp; Expansion Bus Status)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eCompatible Transmitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eIC200ETM001 or equivalent VersaMax transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Requirements \u0026amp; Slot Installation Rules\u003c\/h3\u003e\n\u003cp\u003eTo integrate the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200ERM001\u003c\/strong\u003e\u003c\/span\u003e module properly into a VersaMax system, adhere to these mechanical and electrical rules:\u003c\/p\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePhysical Mounting \u0026amp; Slot Assignment\u003c\/strong\u003e\n\u003cul style=\"list-style-type: square; margin-top: 4px; padding-left: 25px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFar-Left Position Only:\u003c\/strong\u003e The module must be snapped onto the extreme left position of the DIN rail on the expansion I\/O rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Interlocking:\u003c\/strong\u003e Always disconnect power to the local and expansion power supply units before inserting or removing the receiver unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Address Rotary Switch:\u003c\/strong\u003e Set the front rotary switch to match the intended expansion rack index programmed in the controller software configuration before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Plug:\u003c\/strong\u003e If the module is located at the final expansion rack in the daisy chain, attach a standard 26-pin terminator plug into the bottom D-shell port.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Equipment, Applications \u0026amp; Diagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200ERM001\u003c\/strong\u003e\u003c\/span\u003e provides isolated bus extendibility across complex industrial machine footprints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Machinery \u0026amp; Application Scenarios:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed packaging machines requiring auxiliary I\/O racks located in adjacent enclosure bays.\u003c\/li\u003e\n\u003cli\u003eWater\/wastewater filtration skids where expansion racks gather field instrumentation signals.\u003c\/li\u003e\n\u003cli\u003eMaterial handling conveyor networks spanning extended distances across factory floors.\u003c\/li\u003e\n\u003cli\u003eHVAC plant control cabinets separating high-density digital and analog I\/O points across multiple DIN rails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePOWER LED:\u003c\/strong\u003e Verifies that the local backplane power module is energizing the receiver logic circuits within the required 3.3V–5V window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEXPANSION BUS LED:\u003c\/strong\u003e Solid green indicates active sync and communication with the host transmitter; blinking or unlit states indicate cable disconnection, address mismatch, or missing line termination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eConsider these field implementation details when specifying or commissioning the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eIC200ERM001\u003c\/strong\u003e\u003c\/span\u003e:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Ground Isolation \u0026amp; Noise Immunity:\u003c\/strong\u003e The \"isolated\" designation in this receiver card is crucial for installations spanning separate electrical enclosures. Ground potential differences between cabinets can degrade high-speed expansion bus signals. Using factory-shielded 26-pin cables and verifying panel earth grounding prevents communication drops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Power Booster Integration:\u003c\/strong\u003e When populating expansion racks with high-current discrete or analog modules, ensure the local power supply carrier provides adequate amperage. The receiver unit regulates internal backplane logic voltage, but heavy field I\/O current requires dedicated power booster modules (such as IC200PBR001) connected to the rack power bus.\u003c\/p\u003e\n\u003ch3\u003eLogistics, Packaging \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Protection:\u003c\/strong\u003e Covered by a comprehensive \u003cstrong\u003e12 Months Warranty\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Order Fulfillment:\u003c\/strong\u003e Ships from stock within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Courier Delivery:\u003c\/strong\u003e Worldwide air shipping via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, or \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Packaging:\u003c\/strong\u003e Shipped in anti-static ESD packaging with protective covers fitted over the 26-pin female D-sub connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guide \u0026amp; Technical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Guide: How do I select between different cable lengths for connecting the transmitter to the receiver?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse pre-fabricated, double-shielded 26-pin expansion cables. Select shorter cable lengths whenever possible to minimize signal latency and electrical noise interference across expansion sub-racks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat occurs if two receiver units on the same expansion bus are set to the same rotary switch ID?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn address conflict occurs, causing the CPU to log an I\/O fault, and neither expansion rack will establish stable communications. Each rack must have a unique ID set on its front panel switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the expansion bus LED blinking slowly after powering up the system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA slow blink indicates that the receiver is powered, but the upstream transmitter is either offline, disconnected, or missing the mandatory end-of-line termination plug on the final receiver's lower D-sub port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module supply field power directly to connected output devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The receiver module only distributes internal backplane logic power (3.3V to 5V). Connected field devices and output coils require dedicated 24 VDC or AC power wired directly to the I\/O carriers or external power supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat procedure should be followed when swapping a failed expansion unit during emergency maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDe-energize all power sources to the main CPU rack and the targeted expansion rack. Disconnect the upper and lower D-sub cables, copy the exact rotary switch setting from the old card to the replacement unit, mount it on the DIN rail, reattach cables, and restore power.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014000599222,"sku":"IC200ERM001","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200ERM001.jpg?v=1788163452","url":"https:\/\/www.plcsparehub.com\/products\/ic200erm001-ge-fanuc-versamax-expansion-module-in-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}