{"product_id":"ic200cpue05-ethernet-central-processing-unit-ge-fanuc","title":"IC200CPUE05 Ethernet Central Processing Unit GE Fanuc","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC200CPUE05\u003c\/strong\u003e\u003c\/span\u003e is a compact, high-performance Central Processing Unit (CPU) module belonging to the GE Fanuc \/ Emerson VersaMax Programmable Automation Controller family. Engineered for modular process logic and real-time industrial networking, the controller features 64 KB of user-configurable logic\/data memory and executes Boolean ladder logic at a rate of 0.8 ms per 1K instructions. The \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC200CPUE05\u003c\/strong\u003e\u003c\/span\u003e supports scaling up to 64 expansion I\/O modules or 2048 discrete\/analog I\/O points across horizontal or vertical DIN rail mounting configurations.\u003c\/p\u003e\n\u003cp\u003eDesigned for embedded field communications, the module integrates three physical communication interfaces: one 9-pin Sub-D RS-232 serial port, one 15-pin Sub-D RS-485 serial port, and an RJ-45 10 Mbps Ethernet port (supporting full\/half duplex, 8 concurrent SRTP server connections, and 32 Ethernet Global Data exchanges). Onboard power protection includes an internal supercapacitor providing up to 1 hour of memory backup during brief outages, supplemented by battery backup for extended offline retention up to 6 months.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriple Integrated Communication Interfaces:\u003c\/strong\u003e Onboard RS-232, RS-485, and 10 Mbps Ethernet ports eliminate the need for separate network adapter cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Industrial Ethernet Protocols:\u003c\/strong\u003e Native support for up to 8 SRTP server connections and 32 Ethernet Global Data (EGD) exchange configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Layer Memory Backup Architecture:\u003c\/strong\u003e Integrated supercapacitor provides 1-hour short-term power loss bridge; battery maintains data for up to 6 months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Ladder \u0026amp; Instruction Execution:\u003c\/strong\u003e Fast 0.8 ms\/K Boolean speed supporting floating-point math, 32-bit register manipulation, and Modbus RTU master logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Mechanical Mounting:\u003c\/strong\u003e Direct DIN rail latching allows vertical or horizontal cabinet orientation without thermal derating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Status LED Diagnostics:\u003c\/strong\u003e Bezel indicators display PWR, OK, RUN, FAULT, FORCE, PORT 1, and PORT 2 operational states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDetailed electrical, communications, and functional specifications for the \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC200CPUE05\u003c\/strong\u003e\u003c\/span\u003e are structured below:\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"6\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eSystem Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer \/ Line\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eGE Fanuc\u003c\/strong\u003e \/ Emerson Automation (\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/ge-versamax\"\u003eVersaMax\u003c\/a\u003e PLC Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number \u0026amp; Type\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC200CPUE05\u003c\/strong\u003e\u003c\/span\u003e (Modular Ethernet CPU Controller)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory \u0026amp; Scalability\u003c\/td\u003e\n\u003ctd\u003e64 KB configurable memory; up to 64 expansion modules \/ 2048 I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eProcessing Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBoolean Execution Speed\u003c\/td\u003e\n\u003ctd\u003e0.8 milliseconds per 1K instructions (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Processing Formats\u003c\/td\u003e\n\u003ctd\u003eLadder Diagram, Instruction List, Floating-Point, 32-bit Modbus registers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode Controls\u003c\/td\u003e\n\u003ctd\u003eOnboard RUN\/STOP hardware slide switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eNetwork \u0026amp; Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232 (9-pin Sub-D); 1 x RS-485 (15-pin Sub-D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Physical Layer\u003c\/td\u003e\n\u003ctd\u003e1 x RJ-45 10 Mbps port (Full \/ Half Duplex auto-negotiation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Protocols\u003c\/td\u003e\n\u003ctd\u003e8 SRTP Server connections; 32 EGD exchanges (100 data ranges \/ 1400 bytes max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cstrong\u003eElectrical \u0026amp; Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal Power Consumption\u003c\/td\u003e\n\u003ctd\u003e650 mA @ 3.3 Vdc derived from rack power supply base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Term Memory Retention\u003c\/td\u003e\n\u003ctd\u003eOnboard Supercapacitor provides up to 1 hour continuous backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-Term Memory Retention\u003c\/td\u003e\n\u003ctd\u003eStandard battery maintains memory up to 6 months (5-year uninstalled shelf life)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment and Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed packaging line machinery requiring local Ethernet supervision and Modbus RTU serial device aggregation.\u003c\/li\u003e\n\u003cli\u003eSmall-to-medium municipal water treatment skids utilizing EGD network time synchronization across peer controllers.\u003c\/li\u003e\n\u003cli\u003eStandalone OEM equipment control integrating variable frequency drives over RS-485 and HMI operator panels over RS-232.\u003c\/li\u003e\n\u003cli\u003eRetrofitting legacy GE VersaMax rack assemblies with modern SRTP Ethernet server communication capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities and Firmware Revisions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC200CPUE05\u003c\/strong\u003e\u003c\/span\u003e incorporates dual diagnostic LED arrays positioned at the upper and lower corners of the front bezel. Real-time visual feedback covers power rail health (PWR), CPU boot integrity (OK), logic execution state (RUN), internal hardware\/I\/O faults (FAULT), active point overrides (FORCE), and serial link activity (PORT 1 \/ PORT 2). Firmware revisions deliver evolving protocol features: FW 2.10 (initial release), FW 2.20 (expanded serial baud rates), FW 2.30\/2.31 (enhanced Modbus Master capabilities), and FW 2.2 BE (32-bit register mapping for Modbus RTU Master communications).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting or replacing an \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC200CPUE05\u003c\/strong\u003e\u003c\/span\u003e, pay careful attention to the firmware version suffix installed on the CPU label. If your system relies on 32-bit Modbus RTU register polling for smart field instruments, ensure the unit runs firmware version 2.20 or later (such as revision CPUE05-BE or CPUE05-AD), as older hardware revisions do not natively support 32-bit register data mapping.\u003c\/p\u003e\n\u003cp\u003eDuring plant shutdown maintenance, take advantage of the dual memory retention system. The internal supercapacitor holds logic intact for up to 60 minutes without any battery connected, allowing technicians ample time to swap out the backup coin cell battery without losing PLC registers or forcing a fresh program download from Machine Edition.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance, Shipping, and Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1 x Original \u003cspan style=\"color: #d9534f;\"\u003e\u003cstrong\u003eIC200CPUE05\u003c\/strong\u003e\u003c\/span\u003e VersaMax CPU controller module in anti-static protective box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Covered by a full 12-month replacement warranty effective from invoice issuance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpress Global Courier:\u003c\/strong\u003e Fast international dispatch within 24–48 hours via premium FedEx, UPS, and DHL couriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How long can this CPU hold user program logic when complete cabinet power is disconnected without a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The built-in supercapacitor retains user memory for up to 1 hour without auxiliary power, bridging battery swap windows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What is the maximum number of SRTP client sessions that can connect simultaneously to the Ethernet port?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The embedded 10 Mbps RJ-45 Ethernet port supports up to 8 concurrent SRTP server connections for HMIs and engineering workstations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can this VersaMax controller be mounted vertically inside a shallow control enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Yes, the physical chassis is rated for both vertical and horizontal DIN rail mounting orientations without operational derating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What hardware ports are available for direct serial communication with field devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The unit features one 9-pin Sub-D RS-232 serial interface and one 15-pin Sub-D RS-485 serial interface directly on the housing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Which firmware revision is required if my network architecture relies heavily on Modbus RTU Master protocols?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Select hardware revisions CPUE05-AD (FW 2.31) or CPUE05-BE (FW 2.2), which provide expanded Modbus Master command functions and 32-bit register handling.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45014000533686,"sku":"IC200CPUE05","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/IC200CPUE05.jpg?v=1785145200","url":"https:\/\/www.plcsparehub.com\/products\/ic200cpue05-ethernet-central-processing-unit-ge-fanuc","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}